Alexander V. Rodriguez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alexander V. Rodriguez has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Caleb Kemere
Department of Electrical and Computer Engineering, Rice University
3 shared publications - Jacob T. Robinson
Rice University
3 shared publications - Blake Madruga
University of California, Los Angeles, Department of Neurology, David Geffen School of Medicine, Los Angeles, California, United States
1 shared publication - Bo Fan
Meraki Integrated Corp. (China)
1 shared publication - Conor C. Dorian
University of California, Los Angeles, Department of Neurology, David Geffen School of Medicine, Los Angeles, California, United States
1 shared publication - Daniel Aharoni
UCLA
1 shared publication
Latest Publications
- Open Access
- 1 February 2026
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 13 (S2) , 1-19
MiniFAST: a sensitive and fast miniaturized microscope for in vivo neural recording
SignificanceObserving the activity of large populations of neurons in vivo is critical for understanding brain function and dysfunction. The use of fluorescent genetically encoded calcium indicators (GECIs) in conjunction with miniaturized microscopes is an exciting emerging toolset for recording neural activity in unrestrained animals. Despite their potential, current miniaturized microscope designs are limited using image sensors with low frame rates, sensitivity, and resolution. Beyond GECIs, there are many neuroscience applications that would benefit from the use of other emerging neural indicators, such as fluorescent genetically encoded voltage indicators (GEVIs) that have faster temporal resolution to match neuron spiking, yet require imaging at high speeds.AimWe integrated an advanced CMOS image sensor into a popular open-source one-photon miniaturized microscope platform.ApproachMiniFAST is a fast and sensitive miniaturized microscope capable of 1080p video (1920×1080 pixels), 1.5 μm resolution, frame rates up to 500 Hz (achieved with windowing: 1920×55 pixels height), and high gain ability (up to 70 dB) to image in extremely low-light conditions.ResultsWe report results of ∼300-Hz in vivo imaging of freely behaving transgenic Thy1-GCaMP6f mice, high-speed 500-Hz in vitro imaging of a GEVI, and in vivo GEVI imaging in head-fixed mice.ConclusionsOur results extend miniaturized microscope capabilities in high-speed imaging, high sensitivity, and increased resolution.
- 1 February 2026
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 13 (S2) , 1-19
Open AccessMiniFAST: a sensitive and fast miniaturized microscope for in vivo neural recording
SignificanceObserving the activity of large populations of neurons in vivo is critical for understanding brain function and dysfunction. The use of fluorescent genetically encoded calcium indicators (GECIs) in conjunction with miniaturized microscopes is an exciting emerging toolset for recording neural activity in unrestrained animals. Despite their potential, current miniaturized microscope designs are limited using image sensors with low frame rates, sensitivity, and resolution. Beyond GECIs, there are many neuroscience applications that would benefit from the use of other emerging neural indicators, such as fluorescent genetically encoded voltage indicators (GEVIs) that have faster temporal resolution to match neuron spiking, yet require imaging at high speeds.AimWe integrated an advanced CMOS image sensor into a popular open-source one-photon miniaturized microscope platform.ApproachMiniFAST is a fast and sensitive miniaturized microscope capable of 1080p video (1920×1080 pixels), 1.5 μm resolution, frame rates up to 500 Hz (achieved with windowing: 1920×55 pixels height), and high gain ability (up to 70 dB) to image in extremely low-light conditions.ResultsWe report results of ∼300-Hz in vivo imaging of freely behaving transgenic Thy1-GCaMP6f mice, high-speed 500-Hz in vitro imaging of a GEVI, and in vivo GEVI imaging in head-fixed mice.ConclusionsOur results extend miniaturized microscope capabilities in high-speed imaging, high sensitivity, and increased resolution.
- Open Access
Sputtered porous Pt for wafer-scale manufacture of low-impedance flexible microelectrodes
Recording electrical activity from individual cells in vivo is a key technology for basic neuroscience and has growing clinical applications. To maximize the number of independent recording channels as well as the longevity, and quality of these recordings, researchers often turn to small and flexible electrodes that minimize tissue damage and can isolate signals from individual neurons. One challenge when creating these small electrodes, however, is to maintain a low interfacial impedance by applying a surface coating that is stable in tissue and does not significantly complicate the fabrication process. Here we use a high-pressure Pt sputtering process to create low-impedance electrodes at the wafer scale using standard microfabrication equipment. Direct-sputtered Pt provides a reliable and well-controlled porous coating that reduces the electrode impedance by 5-9 fold compared to flat Pt and is compatible with the microfabrication technologies used to create flexible electrodes. These porous Pt electrodes show reduced thermal noise that matches theoretical predictions. In addition, we show that these electrodes can be implanted into rat cortex, record single unit activity, and be removed all without disrupting the integrity of the coating. We also demonstrate that the shape of the electrode (in addition to the surface area) has a significant effect on the electrode impedance when the feature sizes are on the order of tens of microns. Overall, porous Pt represents a promising method for manufacturing low-impedance electrodes that can be seamlessly integrated into existing processes for producing flexible neural probes.
Open AccessSputtered porous Pt for wafer-scale manufacture of low-impedance flexible microelectrodes
Recording electrical activity from individual cells in vivo is a key technology for basic neuroscience and has growing clinical applications. To maximize the number of independent recording channels as well as the longevity, and quality of these recordings, researchers often turn to small and flexible electrodes that minimize tissue damage and can isolate signals from individual neurons. One challenge when creating these small electrodes, however, is to maintain a low interfacial impedance by applying a surface coating that is stable in tissue and does not significantly complicate the fabrication process. Here we use a high-pressure Pt sputtering process to create low-impedance electrodes at the wafer scale using standard microfabrication equipment. Direct-sputtered Pt provides a reliable and well-controlled porous coating that reduces the electrode impedance by 5-9 fold compared to flat Pt and is compatible with the microfabrication technologies used to create flexible electrodes. These porous Pt electrodes show reduced thermal noise that matches theoretical predictions. In addition, we show that these electrodes can be implanted into rat cortex, record single unit activity, and be removed all without disrupting the integrity of the coating. We also demonstrate that the shape of the electrode (in addition to the surface area) has a significant effect on the electrode impedance when the feature sizes are on the order of tens of microns. Overall, porous Pt represents a promising method for manufacturing low-impedance electrodes that can be seamlessly integrated into existing processes for producing flexible neural probes.
- Open Access
Fluidic microactuation of flexible electrodes for neural recording
Ultra-flexible microelectrodes that can bend and flex with the natural movement of the brain reduce the inflammatory response and improve the stability of long-term neural recordings. 1-5 However, current methods to implant these highly flexible electrodes rely on temporary stiffening agents that increase the electrode size 6-10 thus aggravating neural damage during implantation, which leads to cell loss and glial activation that persists even after the stiffening agents are removed or dissolve. 11-13 A method to deliver thin, ultra-flexible electrodes deep into neural tissue without increasing the stiffness or size of the electrodes will enable minimally invasive electrical recordings from within the brain. Here we show that specially designed microfluidic devices can apply a tension force to ultra-flexible electrodes that prevents buckling without increasing the thickness or stiffness of the electrode during implantation. Additionally, these “fluidic microdrives” allow us to precisely actuate the electrode position with micron-scale accuracy. To demonstrate the efficacy of our fluidic microdrives, we used them to actuate highly flexible carbon nanotube fiber (CNTf) microelectrodes 11,14 for electrophysiology. We used this approach in three proof-of-concept experiments. First, we recorded compound action potentials in a soft model organism, the small cnidarian Hydra . Second, we targeted electrodes precisely to the thalamic reticular nucleus in brain slices and recorded spontaneous and optogenetically-evoked extracellular action potentials. Finally, we inserted electrodes more than 4 mm deep into the brain of rats and detected spontaneous individual unit activity in both cortical and subcortical regions. Compared to syringe injection, fluidic microdrives do not penetrate the brain and prevent changes in intracranial pressure by diverting fluid away from the injection site during insertion and actuation. Overall, the fluidic microdrive technology provides a robust new method to implant and actuate ultra-flexible neural electrodes.
Open AccessFluidic microactuation of flexible electrodes for neural recording
Ultra-flexible microelectrodes that can bend and flex with the natural movement of the brain reduce the inflammatory response and improve the stability of long-term neural recordings. 1-5 However, current methods to implant these highly flexible electrodes rely on temporary stiffening agents that increase the electrode size 6-10 thus aggravating neural damage during implantation, which leads to cell loss and glial activation that persists even after the stiffening agents are removed or dissolve. 11-13 A method to deliver thin, ultra-flexible electrodes deep into neural tissue without increasing the stiffness or size of the electrodes will enable minimally invasive electrical recordings from within the brain. Here we show that specially designed microfluidic devices can apply a tension force to ultra-flexible electrodes that prevents buckling without increasing the thickness or stiffness of the electrode during implantation. Additionally, these “fluidic microdrives” allow us to precisely actuate the electrode position with micron-scale accuracy. To demonstrate the efficacy of our fluidic microdrives, we used them to actuate highly flexible carbon nanotube fiber (CNTf) microelectrodes 11,14 for electrophysiology. We used this approach in three proof-of-concept experiments. First, we recorded compound action potentials in a soft model organism, the small cnidarian Hydra . Second, we targeted electrodes precisely to the thalamic reticular nucleus in brain slices and recorded spontaneous and optogenetically-evoked extracellular action potentials. Finally, we inserted electrodes more than 4 mm deep into the brain of rats and detected spontaneous individual unit activity in both cortical and subcortical regions. Compared to syringe injection, fluidic microdrives do not penetrate the brain and prevent changes in intracranial pressure by diverting fluid away from the injection site during insertion and actuation. Overall, the fluidic microdrive technology provides a robust new method to implant and actuate ultra-flexible neural electrodes.