This article discusses the operation of a three phase grid-connected inverter with $LCL$ filter under an unbalanced/distorted grid voltage condition. Two case studies are considered in this article that relate to the operation during grid side current and voltage sensor failure. First, a case study showing the operation of the inverter during a grid side current sensor failure is discussed. Second, a case study showing a grid voltage sensor failure is discussed. For the grid side current sensor failure methodology is developed and discussed to estimate the grid current from the sensed inverter current and the capacitor voltage reference. For the grid side voltage sensor failure, an internal model based grid voltage estimation architecture is proposed, and both its local and global stability analyses are presented. The controller design is based on the Lyapunov energy function, and its derivation during the two types of sensors failure have been discussed and presented along with a detailed mathematical analysis. The proposed architecture is verified on a reduced-scale laboratory prototype, and various case study results are presented.Keywords
Funding Information
- National Science Foundation (1610396, 1406156)
This publication has 21 references indexed in Scilit:
- Improved passivity‐based control method and its robustness analysis for single‐phase uninterruptible power supply invertersIET Power Electronics, 2015
- Conventional Synchronous Reference Frame Phase-Locked Loop is an Adaptive Complex FilterIEEE Transactions on Industrial Electronics, 2014
- Influence of Delay on System Stability and Delay Optimization of Grid-Connected Inverters With LCL FilterIEEE Transactions on Industrial Informatics, 2014
- Linking Corrosion and Catastrophic Failure in Low-Power Metallized Polypropylene CapacitorsIEEE Transactions on Device and Materials Reliability, 2006
- Analysis of Multiloop Control Strategies for LC/CL/LCL-Filtered Voltage-Source and Current-Source InvertersIEEE Transactions on Industry Applications, 2005
- Simple Direct Power Control of Three-Phase PWM Rectifier Using Space-Vector Modulation (DPC-SVM)IEEE Transactions on Industrial Electronics, 2004
- Grid current regulation of a three-phase voltage source inverter with an LCL input filterIEEE Transactions on Power Electronics, 2003
- Current control techniques for three-phase voltage-source PWM converters: a surveyIEEE Transactions on Industrial Electronics, 1998
- Model-based current control of AC machines using the internal model control methodIEEE Transactions on Industry Applications, 1998