Vikram Roy Chowdhury
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Vikram Roy Chowdhury has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Barry Mather
Power Systems Engineering Center, National Laboratory of the Rockies, Golden, CO, USA
4 shared publications - Jonathan W. Kimball
Department of Electrical and Computer Engineering, Missouri University of Science and Technology, Rolla, MO, USA
3 shared publications - Akanksha Singh
DNV, Lakewood, CO, USA
2 shared publications - Mehdi Ferdowsi
Missouri University of Science and Technology
2 shared publications - Pourya Shamsi
Department of Electrical and Computer Engineering, Missouri University of Science and Technology, Rolla, MO, USA
2 shared publications - Subhajyoti Mukherjee
Department of Electrical and Computer Engineering, Missouri University of Science and Technology, Rolla, MO, USA
2 shared publications
Latest Publications
- 23 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (4) , 6763-6778
Virtual Self-Excited Induction Generator-Based Grid-Forming Inverter Control for Robust Voltage Regulation Under Nonideal Loading
This paper presents a generator-inspired control methodology for grid-forming (GFM) inverters that deliberately emulates a self-excited induction generator so that the inverter can hold its voltage and frequency under difficult loading and severe terminal disturbances across wide voltage and frequency ranges. The design integrates a Lyapunov energy function-based inner loop to provide high bandwidth and strong disturbance rejection, and it complements this with a passivity-based argument that furnishes a coherent large-signal stability guarantee beyond small-signal limits. Analytical insights are developed via the Krylov-Bogoliubov-Mitropolsky averaging method, which reveals an intrinsic resistive droop characteristic; these closed-form relations both explain the observed dynamics and yield simple, decentralized tuning rules. The methodology is validated on a controller-hardware-in-the-loop platform and exercised in real time across balanced, unbalanced, and nonlinear loads, as well as during parallel operation. Across these scenarios, the inverter maintains balanced three-phase voltages, limits harmonic content, settles quickly with well-damped transients, and remains resilient when multiple units operate in parallel. The contributions are a self-excited-machine–inspired GFM controller with enhanced dynamic performance and robustness, a single stability rationale grounded in passivity, closed-form expressions that guide tuning, and comprehensive hardware-in-the-loop validations demonstrating effectiveness and superiority under challenging operating conditions.
- 23 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (4) , 6763-6778
Virtual Self-Excited Induction Generator-Based Grid-Forming Inverter Control for Robust Voltage Regulation Under Nonideal Loading
This paper presents a generator-inspired control methodology for grid-forming (GFM) inverters that deliberately emulates a self-excited induction generator so that the inverter can hold its voltage and frequency under difficult loading and severe terminal disturbances across wide voltage and frequency ranges. The design integrates a Lyapunov energy function-based inner loop to provide high bandwidth and strong disturbance rejection, and it complements this with a passivity-based argument that furnishes a coherent large-signal stability guarantee beyond small-signal limits. Analytical insights are developed via the Krylov-Bogoliubov-Mitropolsky averaging method, which reveals an intrinsic resistive droop characteristic; these closed-form relations both explain the observed dynamics and yield simple, decentralized tuning rules. The methodology is validated on a controller-hardware-in-the-loop platform and exercised in real time across balanced, unbalanced, and nonlinear loads, as well as during parallel operation. Across these scenarios, the inverter maintains balanced three-phase voltages, limits harmonic content, settles quickly with well-damped transients, and remains resilient when multiple units operate in parallel. The contributions are a self-excited-machine–inspired GFM controller with enhanced dynamic performance and robustness, a single stability rationale grounded in passivity, closed-form expressions that guide tuning, and comprehensive hardware-in-the-loop validations demonstrating effectiveness and superiority under challenging operating conditions.
- 12 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (4) , 5022-5047
Analysis of Transformer Magnetizing Reactance Using Describing Function in Direct Power Control of Back-to-Back Modular Multilevel Converter with Advanced Grid Support
This paper presents a Port Controlled Hamiltonian based direct power control architecture for a back-to-back modular multilevel converter system connecting two ac sources at different frequencies. The system features advanced grid support functionalities based on IEEE 1547-2018, implemented on the inverter side. The rectifier side controller ensures reference following for active and/or reactive powers and maintains the commanded dc bus voltage. The inverter side controller ensures power command following for active and reactive powers.The proposed control architecture is designed to suppress second harmonic oscillations in powers during unbalanced grid voltage sags by dynamically adjusting the currents on each ac side. This also ensures effective elimination of any second harmonic oscillations in the equivalent dc bus voltage. Validation is performed on an OPAL-RT real-time platform with case studies on unbalanced and balanced sags, demonstrating the controller’s effectiveness during real time implementation. A reduced-scale laboratory prototype further verifies these case studies, with experimental results for balanced sags due to grid simulator limitations. The results confirm the robustness and efficiency of the proposed control strategy in ensuring stable and reliable operation under various grid conditions.
- 12 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (4) , 5022-5047
Analysis of Transformer Magnetizing Reactance Using Describing Function in Direct Power Control of Back-to-Back Modular Multilevel Converter with Advanced Grid Support
This paper presents a Port Controlled Hamiltonian based direct power control architecture for a back-to-back modular multilevel converter system connecting two ac sources at different frequencies. The system features advanced grid support functionalities based on IEEE 1547-2018, implemented on the inverter side. The rectifier side controller ensures reference following for active and/or reactive powers and maintains the commanded dc bus voltage. The inverter side controller ensures power command following for active and reactive powers.The proposed control architecture is designed to suppress second harmonic oscillations in powers during unbalanced grid voltage sags by dynamically adjusting the currents on each ac side. This also ensures effective elimination of any second harmonic oscillations in the equivalent dc bus voltage. Validation is performed on an OPAL-RT real-time platform with case studies on unbalanced and balanced sags, demonstrating the controller’s effectiveness during real time implementation. A reduced-scale laboratory prototype further verifies these case studies, with experimental results for balanced sags due to grid simulator limitations. The results confirm the robustness and efficiency of the proposed control strategy in ensuring stable and reliable operation under various grid conditions.
- 27 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (10) , 12177-12182
Autonomous Grid Support Functionality in Variable-Speed Drive-Based End-Use Loads
High penetration of inverter-based resources into power systems causes lower inertia, and it becomes more challenging to maintain grid stability during contingency events. While conventional demand response and shedding at the load side suffer from slow response, impact by unavailability, and issues from communication, variable-speed drives (VSDs) are becoming strong candidates for fast frequency response (FFR) thanks to their fast response and reduced user impact from variable power adjustment capability. In this letter, we propose an autonomous frequency support control method for a residential refrigerator with a VSD, a promising target small end-use load for FFR. We analyze the effect of the proposed controller on grid stability, and we verify the performance through laboratory experiments with a commercially available refrigerator.
- 27 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (10) , 12177-12182
Autonomous Grid Support Functionality in Variable-Speed Drive-Based End-Use Loads
High penetration of inverter-based resources into power systems causes lower inertia, and it becomes more challenging to maintain grid stability during contingency events. While conventional demand response and shedding at the load side suffer from slow response, impact by unavailability, and issues from communication, variable-speed drives (VSDs) are becoming strong candidates for fast frequency response (FFR) thanks to their fast response and reduced user impact from variable power adjustment capability. In this letter, we propose an autonomous frequency support control method for a residential refrigerator with a VSD, a promising target small end-use load for FFR. We analyze the effect of the proposed controller on grid stability, and we verify the performance through laboratory experiments with a commercially available refrigerator.
- 5 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 4 (2) , 589-602
Enhanced Operation of a Virtual Synchronous Machine Under Unbalanced Grid Voltage Condition Based on Lyapunov Energy Function
Three-phase grid connected inverters integrated with renewable energy sources like photo-voltaic systems require to provide inertia to damp out oscillations in the frequency. However, during grid voltage sag or unbalance classical virtual synchronous machines cannot maintain oscillation free power supplied to the grid. Therefore, the maximum power point tracking of the photo-voltaic system cannot be maintained, and optimal usage of the available photovoltaic power cannot be accomplished. To cater this problem, in this paper a Lyapunov energy function based augmented controller architecture has been proposed alongside a virtual synchronous machine during unbalanced grid voltage to effectively suppress these double frequency oscillations in the power. Identifying the dynamics of these oscillations followed by detailed stability analyses for the proposed architecture have been presented. In comparison to classical virtual synchronous machines, the augmented system provides better transient response as well as double frequency power oscillation damping during grid voltage sag or unbalance. To verify the efficacy and understand the challenges of practical implementation of the proposed architecture, experimental verification on a reduced scale laboratory prototype is performed and various important case study results are obtained and presented in this paper.
- 5 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 4 (2) , 589-602
Enhanced Operation of a Virtual Synchronous Machine Under Unbalanced Grid Voltage Condition Based on Lyapunov Energy Function
Three-phase grid connected inverters integrated with renewable energy sources like photo-voltaic systems require to provide inertia to damp out oscillations in the frequency. However, during grid voltage sag or unbalance classical virtual synchronous machines cannot maintain oscillation free power supplied to the grid. Therefore, the maximum power point tracking of the photo-voltaic system cannot be maintained, and optimal usage of the available photovoltaic power cannot be accomplished. To cater this problem, in this paper a Lyapunov energy function based augmented controller architecture has been proposed alongside a virtual synchronous machine during unbalanced grid voltage to effectively suppress these double frequency oscillations in the power. Identifying the dynamics of these oscillations followed by detailed stability analyses for the proposed architecture have been presented. In comparison to classical virtual synchronous machines, the augmented system provides better transient response as well as double frequency power oscillation damping during grid voltage sag or unbalance. To verify the efficacy and understand the challenges of practical implementation of the proposed architecture, experimental verification on a reduced scale laboratory prototype is performed and various important case study results are obtained and presented in this paper.
- 9 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 01-07
Control and Grid Support Function Evaluation for a Three-Phase Back-to-Back Modular Multilevel Converter System
This paper focuses on the evaluation of advanced inverter controls for a 500kW back-to-back (B2B), silicon carbide, multilevel modular converter (MMC) used as a direct-connected medium-voltage grid intertie. A decentralized hierarchical controller architecture for the MMC system is presented, which uses the main controller to implement higher level grid interconnection functions per the IEEE 1547–2018 standards and the local controllers to execute lower level closed-loop functionality of the MMC stages. This paper presents and elaborates on the grid functionalities are elaborated and presented. The back-to-back converter system is equipped with local controllers and their corresponding functionalities are presented. Case study results for the corresponding functionalities presented show the effectiveness of the proposed architecture. To enhance the operation capabilities of the system, a parameter update scheme has been implemented and utilized in unison with the controller.
- 9 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 01-07
Control and Grid Support Function Evaluation for a Three-Phase Back-to-Back Modular Multilevel Converter System
This paper focuses on the evaluation of advanced inverter controls for a 500kW back-to-back (B2B), silicon carbide, multilevel modular converter (MMC) used as a direct-connected medium-voltage grid intertie. A decentralized hierarchical controller architecture for the MMC system is presented, which uses the main controller to implement higher level grid interconnection functions per the IEEE 1547–2018 standards and the local controllers to execute lower level closed-loop functionality of the MMC stages. This paper presents and elaborates on the grid functionalities are elaborated and presented. The back-to-back converter system is equipped with local controllers and their corresponding functionalities are presented. Case study results for the corresponding functionalities presented show the effectiveness of the proposed architecture. To enhance the operation capabilities of the system, a parameter update scheme has been implemented and utilized in unison with the controller.
- 21 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (11) , 13808-13823
A Tri-Port Current-Source Soft-Switching Medium-Voltage String Inverter for Large-Scale Solar-Plus-Storage Farms
This article presents a tri-port current-source soft-switching medium-voltage string inverter (TMVSI) to reduce the Levelized cost of energy (LCOE) of large-scale solar-plus-storage (SPS) farms. Throughout this work, the topology, operating principle, circuit simulation, control, and hardware design of the TMVSI are introduced. In addition, three key challenges compromising the performance of the TMVSI are addressed in this article. First, a new feed-forward compensation for model predictive control of the TMVSI is proposed to compensate for sampling and computational delay and high dc-link ripple with low computational cost and high scalability. Second, the use of laminated permanent magnets is proposed to reduce the losses of the MV medium-frequency transformer (MFT) in the TMVSI while increasing its saturation current. Finally, an improved U-shape winding pattern is proposed to decrease the leakage inductance of the MV MFT and reduce the voltage stress across semiconductor switches without adding cost or complexity. The effectiveness of the TMVSI is validated by experiments at up to $20\,\mathrm{kW/500\,V}$ in different test cases with custom-built prototypes. The contributions of this work make the TMVSI a viable solution to SPS farms and unleash its potential for LCOE reduction.
- 21 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (11) , 13808-13823
A Tri-Port Current-Source Soft-Switching Medium-Voltage String Inverter for Large-Scale Solar-Plus-Storage Farms
This article presents a tri-port current-source soft-switching medium-voltage string inverter (TMVSI) to reduce the Levelized cost of energy (LCOE) of large-scale solar-plus-storage (SPS) farms. Throughout this work, the topology, operating principle, circuit simulation, control, and hardware design of the TMVSI are introduced. In addition, three key challenges compromising the performance of the TMVSI are addressed in this article. First, a new feed-forward compensation for model predictive control of the TMVSI is proposed to compensate for sampling and computational delay and high dc-link ripple with low computational cost and high scalability. Second, the use of laminated permanent magnets is proposed to reduce the losses of the MV medium-frequency transformer (MFT) in the TMVSI while increasing its saturation current. Finally, an improved U-shape winding pattern is proposed to decrease the leakage inductance of the MV MFT and reduce the voltage stress across semiconductor switches without adding cost or complexity. The effectiveness of the TMVSI is validated by experiments at up to $20\,\mathrm{kW/500\,V}$ in different test cases with custom-built prototypes. The contributions of this work make the TMVSI a viable solution to SPS farms and unleash its potential for LCOE reduction.
- 13 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36 (4) , 3568-3577
Internal Model Based Grid Voltage Estimation and Control of a Three-Phase Grid Connected Inverter for $PV$ ApplicationGrid connected inverters for its successful operation require the magnitude and phase of the point of common coupling voltage for the generation of unit vectors from an architecture popularly known as phase locked loops. However, during weak grid conditions or when the grid voltage sensor fails, it might become immensely challenging to operate the inverter due to unknown grid impedance which causes instability in the phase locked loop. In this paper, an internal model based grid voltage estimation architecture has been presented. The proposed control architecture relies on the current measurements along with nominal values of filter parameters for the point of common coupling voltage estimation and generates the unit vectors. Detailed stiffness and robustness analyses are presented to show that the proposed control come estimation architecture is nearly insensitive to parameter variations. In comparison to conventional current control with both voltage and current sensors, the proposed current control scheme provides better transient response during both ideal and non-ideal grid voltage conditions. Experimental results on a reduced scale laboratory prototype validate the efficacy of the proposed architecture.
- 13 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36 (4) , 3568-3577
Internal Model Based Grid Voltage Estimation and Control of a Three-Phase Grid Connected Inverter for $PV$ ApplicationGrid connected inverters for its successful operation require the magnitude and phase of the point of common coupling voltage for the generation of unit vectors from an architecture popularly known as phase locked loops. However, during weak grid conditions or when the grid voltage sensor fails, it might become immensely challenging to operate the inverter due to unknown grid impedance which causes instability in the phase locked loop. In this paper, an internal model based grid voltage estimation architecture has been presented. The proposed control architecture relies on the current measurements along with nominal values of filter parameters for the point of common coupling voltage estimation and generates the unit vectors. Detailed stiffness and robustness analyses are presented to show that the proposed control come estimation architecture is nearly insensitive to parameter variations. In comparison to conventional current control with both voltage and current sensors, the proposed current control scheme provides better transient response during both ideal and non-ideal grid voltage conditions. Experimental results on a reduced scale laboratory prototype validate the efficacy of the proposed architecture.
- Open Access
- 1 October 2020
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 13 (15) , 3496-3504
Virtual charge‐based synchronisation and feedback linearisation‐based current control of a three‐phase grid‐connected inverter without grid voltage sensors
A conventional synchronous (rotating) reference frame control requires small‐signal models and introduces cross‐coupling terms. In this study, a virtual charge‐based scheme for grid synchronisation with only current measurements has been proposed for a three‐phase grid‐connected inverter with a first‐order filter. The methodology described in this study curbs the dependency of the inverter on the information of the grid voltage to generate unit vectors from the phase‐locked loop. This kind of estimation is especially important during grid voltage sensor failures or a distant point common coupling or weak grid conditions. In the proposed estimation scheme, no noisy differentiation is involved and only the nominal values of the interfacing filter parameters are utilised, making the implementation easier in digital microcontrollers. Also, a current control architecture based on feedback linearisation concept has been explored and embedded with the proposed grid voltage estimation technique, and the corresponding performance has been evaluated via simulation and experimental studies.
- 1 October 2020
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 13 (15) , 3496-3504
Open AccessVirtual charge‐based synchronisation and feedback linearisation‐based current control of a three‐phase grid‐connected inverter without grid voltage sensors
A conventional synchronous (rotating) reference frame control requires small‐signal models and introduces cross‐coupling terms. In this study, a virtual charge‐based scheme for grid synchronisation with only current measurements has been proposed for a three‐phase grid‐connected inverter with a first‐order filter. The methodology described in this study curbs the dependency of the inverter on the information of the grid voltage to generate unit vectors from the phase‐locked loop. This kind of estimation is especially important during grid voltage sensor failures or a distant point common coupling or weak grid conditions. In the proposed estimation scheme, no noisy differentiation is involved and only the nominal values of the interfacing filter parameters are utilised, making the implementation easier in digital microcontrollers. Also, a current control architecture based on feedback linearisation concept has been explored and embedded with the proposed grid voltage estimation technique, and the corresponding performance has been evaluated via simulation and experimental studies.
- 6 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (9) , 8253-8264
Robust Control Scheme for a Three Phase Grid-Tied Inverter With $LCL$ Filter During Sensor FailuresThis article discusses the operation of a three phase grid-connected inverter with $LCL$ filter under an unbalanced/distorted grid voltage condition. Two case studies are considered in this article that relate to the operation during grid side current and voltage sensor failure. First, a case study showing the operation of the inverter during a grid side current sensor failure is discussed. Second, a case study showing a grid voltage sensor failure is discussed. For the grid side current sensor failure methodology is developed and discussed to estimate the grid current from the sensed inverter current and the capacitor voltage reference. For the grid side voltage sensor failure, an internal model based grid voltage estimation architecture is proposed, and both its local and global stability analyses are presented. The controller design is based on the Lyapunov energy function, and its derivation during the two types of sensors failure have been discussed and presented along with a detailed mathematical analysis. The proposed architecture is verified on a reduced-scale laboratory prototype, and various case study results are presented.
- 6 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (9) , 8253-8264
Robust Control Scheme for a Three Phase Grid-Tied Inverter With $LCL$ Filter During Sensor FailuresThis article discusses the operation of a three phase grid-connected inverter with $LCL$ filter under an unbalanced/distorted grid voltage condition. Two case studies are considered in this article that relate to the operation during grid side current and voltage sensor failure. First, a case study showing the operation of the inverter during a grid side current sensor failure is discussed. Second, a case study showing a grid voltage sensor failure is discussed. For the grid side current sensor failure methodology is developed and discussed to estimate the grid current from the sensed inverter current and the capacitor voltage reference. For the grid side voltage sensor failure, an internal model based grid voltage estimation architecture is proposed, and both its local and global stability analyses are presented. The controller design is based on the Lyapunov energy function, and its derivation during the two types of sensors failure have been discussed and presented along with a detailed mathematical analysis. The proposed architecture is verified on a reduced-scale laboratory prototype, and various case study results are presented.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2979-2984
Grid Voltage Estimation and Feedback Linearization based Control of a Three phase Grid Connected Inverter under Unbalanced Grid Conditions with LCL Filter
Voltage sensing in a three phase grid connected inverter is expensive and introduces vulnerability in the presence of faulty components. A feedback linearization based current control strategy independent of grid voltage sensor information is presented in this paper. Initially the current controller is tuned with the assumption of known grid voltage. Next, an internal model based grid voltage estimation technique is proposed to estimate the grid voltage by using the error of the grid current and known filter parameters. The estimated grid voltage from the proposed technique was utilized in feedback linearization based current control to achieve successful current control. The proposed method has been verified via computer simulations based on MATLAB R/Simulink R and PLECS R and the efficacy of the system was checked with various case studies.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2979-2984
Grid Voltage Estimation and Feedback Linearization based Control of a Three phase Grid Connected Inverter under Unbalanced Grid Conditions with LCL Filter
Voltage sensing in a three phase grid connected inverter is expensive and introduces vulnerability in the presence of faulty components. A feedback linearization based current control strategy independent of grid voltage sensor information is presented in this paper. Initially the current controller is tuned with the assumption of known grid voltage. Next, an internal model based grid voltage estimation technique is proposed to estimate the grid voltage by using the error of the grid current and known filter parameters. The estimated grid voltage from the proposed technique was utilized in feedback linearization based current control to achieve successful current control. The proposed method has been verified via computer simulations based on MATLAB R/Simulink R and PLECS R and the efficacy of the system was checked with various case studies.