The significance of coefficient of variation as a measure of hypoglycaemia risk and glycaemic control in real world users of the automated insulin delivery MiniMed 780G system
Open Access
- 29 May 2023
- journal article
- research article
- Published by Wiley in Diabetes, Obesity and Metabolism
- Vol. 25 (9) , 2545-2552
Abstract
Aim: Use of the MiniMed 780G system (MM780G) can result in a reduction in mean and standard deviation (SD) of sensor glucose (SG) values. We assessed the significance of the coefficient of variation (CV) as a measure of hypoglycaemia risk and glycaemic control. Materials and Methods: Data from 10 404 MM780G users were analysed using multivariable logistic regression to assess the contribution of CV to (a) hypoglycaemia risk, measured as not reaching target 70% and glucose management indicator <7%. CV was compared with SD and low blood glucose index. To assess the relevance of CV <36% as a therapeutic threshold, we identified the CV cut‐off point that optimally discriminated users at risk of hypoglycaemia. Results: The contribution of CV was the smallest in terms of risk of hypoglycaemia (vs. low blood glucose index and SD) and TIR and glucose management indicator targets (vs. SD). In all cases the models with SD showed the best fit. A CV <43.4% (95% CI: 42.9–43.9) was the optimal cut‐off point with a correct classification rate of 87.2% (vs. 72.9% for CV <36%). Conclusion: For MM780G users, CV is a poor marker for hypoglycaemia risk and glycaemic control. We recommend using, for the former, TBR and whether the TBR target is met (and not using CV <36% as a therapeutic threshold for hypoglycaemia); for the latter, TIR, time above range, whether targets are met and a discrete description of mean SG and SD of SG values.Keywords
Funding Information
- Medtronic
This publication has 26 references indexed in Scilit:
- Glycaemic variability in diabetes: clinical and therapeutic implicationsThe Lancet Diabetes & Endocrinology, 2019
- State of Type 1 Diabetes Management and Outcomes from the T1D Exchange in 2016–2018Diabetes Technology & Therapeutics, 2019
- Glucose Variability: A Review of Clinical Applications and Research DevelopmentsDiabetes Technology & Therapeutics, 2018
- Optimal Sampling Duration for Continuous Glucose Monitoring to Determine Long-Term Glycemic ControlDiabetes Technology & Therapeutics, 2018
- International Consensus on Use of Continuous Glucose MonitoringDiabetes Care, 2017
- Toward Defining the Threshold Between Low and High Glucose Variability in DiabetesDiabetes Care, 2016
- Measures of Glycemic Variability in Type 1 Diabetes and the Effect of Real-Time Continuous Glucose MonitoringDiabetes Technology & Therapeutics, 2016
- Glucose concentrations of less than 3.0 mmol/l (54 mg/dl) should be reported in clinical trials: a joint position statement of the American Diabetes Association and the Europian Association for the Study of DiabetesDiabetologia, 2016
- Long-term Glycemic Variability and Risk of Adverse Outcomes: A Systematic Review and Meta-analysisDiabetes Care, 2015
- Assessment of risk for severe hypoglycemia among adults with IDDM: validation of the low blood glucose index.Diabetes Care, 1998