Hydraulic- and Microprocessor-Controlled Ankle-Foot Prostheses for Limited Community Ambulators with Unilateral Transtibial Amputation: Pilot Study
Authors:
- 20 April 2021
- journal article
- research article
- Published by Wolters Kluwer Health in JPO Journal of Prosthetics and Orthotics
- Vol. 33 (4) , 294-303
Abstract
Introduction: In the United States, access to microprocessor-controlled prosthetic ankles is limited to patients with lower-limb loss classified as unlimited community ambulators or greater. However, the potential benefits of these devices have not been evaluated among patients classified as household or limited community ambulators. This study examined the benefit of hydraulic- and microprocessor-controlled prosthetic ankles for patients classified as limited community ambulators. Materials and Methods: Four different treatment configurations were evaluated using a randomized crossover study design. These four configurations included the participant's current flexible keel (FK) prosthetic foot, an energy-storage-and-return foot (ESAR), a hydraulic ankle (HA), and a microprocessor ankle (MPA). After a 2-week accommodation period, both patient-reported and performance-based outcome measures were recorded for each ankle foot system. A StepWatch activity monitor and two-dimensional video motion analysis were also used to evaluate each system. Results: A single participant meeting the inclusion criteria was recruited. The patient-reported mobility and socket fit instruments were greatest with the HA system. When assessed on slopes and stairs, the MPA demonstrated benefits on hill ascent and stair descent. In considering the walking speed and perceived exertion jointly, the HA system allowed similar walking speed but lower exertion compared with fixed-ankle systems. The patient-reported low back pain and balance confidence instruments did not provide useful data for interpretation. Two-dimensional video motion analysis showed that the HA and MPA contributed to improved ankle and knee postures when ascending and descending a slope. The step activity data showed the greatest activity with the HA. Discussion: The results from the outcome measures showed a varying level of benefit across all four of the treatment configurations. Both the HA and MPA had favorable scores in varying performance-based outcome measures, but the HA scored the most favorable in a majority of the patient-reported outcome measures. Conclusion: The results show varying benefits of the microprocessor- and hydraulic-controlled prosthetic components over fixed-ankle ESAR and FK feet, based on both performance-based and patient-reported outcome measures. Further studies are needed to fully evaluate these benefits in larger sample sizes.Keywords
This publication has 42 references indexed in Scilit:
- Walking speed related joint kinetic alterations in trans-tibial amputees: impact of hydraulic 'ankle’ dampingJournal of NeuroEngineering and Rehabilitation, 2013
- The use of the 6-min walk test as a proxy for the assessment of energy expenditure during gait in individuals with lower-limb amputationInternational Journal of Rehabilitation Research, 2011
- Reliability of Outcome Measures for People With Lower-Limb Amputations: Distinguishing True Change From Statistical ErrorPhysical Therapy, 2011
- Pressure characteristics at the stump/socket interface in transtibial amputees using an adaptive prosthetic footClinical Biomechanics, 2009
- Kinematics and kinetics with an adaptive ankle foot system during stair ambulation of transtibial amputeesGait & Posture, 2009
- Comparison of nonmicroprocessor knee mechanism versus C-Leg on Prosthesis Evaluation Questionnaire, stumbles, falls, walking tests, stair descent, and knee preferenceJournal of Rehabilitation Research and Development, 2008
- Activity Levels Among Lower-Limb Amputees: Self-Report Versus Step Activity MonitorArchives of Physical Medicine and Rehabilitation, 2007
- Meaningful Change and Responsiveness in Common Physical Performance Measures in Older AdultsJournal of the American Geriatrics Society, 2006
- Prosthetic socket fit comfort scoreDisability and Rehabilitation, 2003
- A 30-s Chair-Stand Test as a Measure of Lower Body Strength in Community-Residing Older AdultsResearch Quarterly for Exercise and Sport, 1999