A nonlinear and time-dependent leak current in the presence of calcium fluoride patch-clamp seal enhancer
Open Access
- 2 November 2021
- journal article
- research article
- Published by F1000 Research Ltd in Wellcome Open Research
- Vol. 5, 152
Abstract
Automated patch-clamp platforms are widely used and vital tools in both academia and industry to enable high-throughput studies such as drug screening. A leak current to ground occurs whenever the seal between a pipette and cell (or internal solution and cell in high-throughput machines) is not perfectly insulated from the bath (extracellular) solution. Over 1 GΩ seal resistance between pipette and bath solutions is commonly used as a quality standard for manual patch work. With automated platforms it can be difficult to obtain such a high seal resistance between the intra- and extra-cellular solutions. One suggested method to alleviate this problem is using an F− containing internal solution together with a Ca2+ containing external solution — so that a CaF2 crystal forms when the two solutions meet which ‘plugs the holes’ to enhance the seal resistance. However, we observed an unexpected nonlinear-in-voltage and time-dependent current using these solutions on an automated patch-clamp platform. We performed manual patch-clamp experiments with the automated patch-clamp solutions, but no biological cell, and observed the same nonlinear time-dependent leak current. The current could be completely removed by washing out F− ions to leave a conventional leak current that was linear and not time-dependent. We therefore conclude fluoride ions interacting with the CaF2 crystal are the origin of the nonlinear time-dependent leak current. The consequences of such a nonlinear and time-dependent leak current polluting measurements should be considered carefully if it cannot be isolated and subtracted.Keywords
Funding Information
- Biotechnology and Biological Sciences Research Council (BB/P010008/1)
- Engineering and Physical Sciences Research Council (EP/L016044/1)
- Australian Research Council (DP190101758)
- ZonMw (114021501, 114022502)
- Wellcome Trust (212203)
This publication has 31 references indexed in Scilit:
- Variability in high-throughput ion-channel screening data and consequences for cardiac safety assessmentJournal of Pharmacological and Toxicological Methods, 2013
- Development and Validation of HTS Flux Assay for Endogenously Expressed Chloride Channels in a CHO-K1 Cell LineASSAY and Drug Development Technologies, 2006
- Voltage‐dependent blockade of HERG channels expressed in Xenopus oocytes by external Ca2+ and Mg2+The Journal of Physiology, 1998
- Comparison of heterologously expressed human cardiac and skeletal muscle sodium channelsBiophysical Journal, 1996
- Strong voltage-dependent inward rectification of inward rectifier K+ channels is caused by intracellular spermineCell, 1995
- Gated, ion-selective channels observed with patch pipettes in the absence of membranes: novel properties of a gigasealBiophysical Journal, 1993
- Fluoride is a strong and specific inhibitor of (asymmetrical) Ap4A hydrolasesFEBS Letters, 1990
- Patch Clamp Techniques for Studying Ionic Channels in Excitable MembranesAnnual Review of Physiology, 1984
- Effect of internal fluoride and phosphate on membrane currents during intracellular dialysis of nerve cellsNature, 1975
- Divalent Ions and the Surface Potential of Charged Phospholipid MembranesJournal of General Physiology, 1971