MWMonique J. Windley

Monique J. Windley

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Monique J. Windley has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Molecular basis for state-dependent drug block of Kv11.1 (human ether-à-go-go-related gene) potassium channels

    by Claire Jinmeng Zhou, Joanne G. Ma, Chai-Ann Ng, Mark J. Hunter, Matthew D. Perry, Monique Windley, Adam P. Hill, Jamie I. Vandenberg

  • Open Access

    A range of voltage-clamp protocol designs for rapid capture of hERG kinetics

    by Chon Lok Lei, Dominic J Whittaker, Monique J Windley, Matthew D Perry, Adam P Hill, Gary R Mirams

    We provide details of a series of short voltage-clamp protocols designed for gathering a large amount of information on hERG (K v 11.1) ion channel gating. The protocols have a limited number of steps and consist only of steps and ramps, making them easy to implement on any patch clamp setup, including automated platforms. The primary objective is to assist with parameterisation, selection and refinement of mathematical models of hERG gating. We detail a series of manual and automated model-driven designs, together with an explanation of their rationale and design criteria. Experimental data under all these protocols is available in a partner publication. Although the protocols are intended to study hERG1a currents, the approaches could be easily extended and generalised to other ion channel currents.

  • Open Access

    Evaluating the predictive accuracy of ion-channel models using data from multiple experimental designs

    by Joseph G. Shuttleworth, Chon Lok Lei, Monique J. Windley, Adam P. Hill, Simon P. Preston, Gary R. Mirams

    Mathematical models are increasingly being relied upon to provide quantitatively accurate predictions of cardiac electrophysiology. Many such models concern the behaviour of particular subcellular components (namely, ion channels) which, together, allow the propagation of electrical signals through heart-muscle tissue; that is, the firing of action potentials. In particular, I Kr , a voltage-sensitive potassium ion-channel current, is of interest owing to the central pore of its primary protein having a propensity to blockage by various small molecules. We use newly collected data obtained from an ensemble of voltage-clamp experiment designs (protocols) to validate the predictive accuracy of various dynamical models of I Kr . To do this, we fit models to each protocol individually and quantify the error in the resultant model predictions for other protocols. This allows the comparison of predictive accuracy for I Kr models under a diverse collection of previously unexplored dynamics. Our results highlight heterogeneity between parameter estimates obtained from different cells, suggesting the presence of latent effects not yet accounted for in our models. This heterogeneity has a significant effect on our parameter estimates and suggests routes for model improvement. This article is part of the theme issue ‘Uncertainty quantification for healthcare and biological systems (Part 1)’.


  • Open Access

    A range of voltage-clamp protocol designs for rapid capture of hERG kinetics

    by Chon Lok Lei, Dominic J Whittaker, Monique J Windley, Matthew D Perry, Adam P Hill, Gary R Mirams

    We provide details of a series of short voltage-clamp protocols designed for gathering a large amount of information on hERG (Kv11.1) ion channel gating. The protocols have a limited number of steps and consist only of steps and ramps, making them easy to implement on any patch clamp setup, including automated platforms. The primary objective is to assist with parameterisation, selection and refinement of mathematical models of hERG gating. We detail a series of manual and automated model-driven designs, together with an explanation of their rationale and design criteria. Although the protocols are intended to study hERG1a currents, the approaches could be easily extended and generalised to other ion channel currents.

  • Open Access

    Evaluating the predictive accuracy of ion channel models using data from multiple experimental designs

    by Joseph G. Shuttleworth, Chon Lok Lei, Monique J. Windley, Adam P. Hill, Simon P. Preston, Gary R. Mirams

    Mathematical models are increasingly being relied upon to provide quantitatively accurate predictions of cardiac electrophysiology. Many such models concern the behaviour of particular subcellular components (namely, ion channels) which, together, allow the propagation of electrical signals through heart-muscle tissue - namely, the firing of action potentials. In particular, I Kr , a voltage-sensitive potassium ion-channel current, is of interest owing to its central pore's propensity for blockage by various small molecules. We use newly collected data obtained from an ensemble of voltage-clamp experiments to validate the predictive accuracy of various dynamical models of I Kr . To do this, we fit models to each protocol individually, and quantify the error in the resultant model predictions. This allows the comparison of predictive accuracy for I Kr models under a diverse collection of previously unexplored dynamics. Our results highlight heterogeneity between parameter estimates obtained from different cells, suggesting the presence of latent effects not yet accounted for in our models. This heterogeneity has a significant impact on our parameter estimates and suggests routes for model improvement.


  • Open Access

    A range of voltage-clamp protocol designs for rapid capture of hERG kinetics

    by Chon Lok Lei, Dominic G Whittaker, Monique J Windley, Matthew D Perry, Adam P Hill, Gary R Mirams

    We provide details of a series of short voltage-clamp protocols designed for gathering a large amount of information on hERG (K v 11.1) ion channel gating. The protocols have a limited number of steps and consist only of steps and ramps, making them easy to implement on any patch clamp setup, including automated platforms. The primary objective is to assist with parameterisation, selection and refinement of mathematical models of hERG gating. We detail a series of manual and automated model-driven designs, together with an explanation of their rationale and design criteria. Although the protocols are intended to study hERG1a currents, the approaches could be easily extended and generalised to other ion channel currents.

  • Open Access

    Empirical Quantification of Predictive Uncertainty Due to Model Discrepancy by Training with an Ensemble of Experimental Designs: An Application to Ion Channel Kinetics

    by Joseph G. Shuttleworth, Chon Lok Lei, Dominic G. Whittaker, Monique J. Windley, Adam P. Hill, Simon P. Preston, Gary R. Mirams

    When using mathematical models to make quantitative predictions for clinical or industrial use, it is important that predictions come with a reliable estimate of their accuracy (uncertainty quantification). Because models of complex biological systems are always large simplifications, model discrepancy arises—models fail to perfectly recapitulate the true data generating process. This presents a particular challenge for making accurate predictions, and especially for accurately quantifying uncertainty in these predictions. Experimentalists and modellers must choose which experimental procedures (protocols) are used to produce data used to train models. We propose to characterise uncertainty owing to model discrepancy with an ensemble of parameter sets, each of which results from training to data from a different protocol. The variability in predictions from this ensemble provides an empirical estimate of predictive uncertainty owing to model discrepancy, even for unseen protocols. We use the example of electrophysiology experiments that investigate the properties of hERG potassium channels. Here, ‘information-rich’ protocols allow mathematical models to be trained using numerous short experiments performed on the same cell. In this case, we simulate data with one model and fit it with a different (discrepant) one. For any individual experimental protocol, parameter estimates vary little under repeated samples from the assumed additive independent Gaussian noise model. Yet parameter sets arising from the same model applied to different experiments conflict—highlighting model discrepancy. Our methods will help select more suitable ion channel models for future studies, and will be widely applicable to a range of biological modelling problems.


  • High throughput measurement of hERG drug block kinetics using the CiPA dynamic protocol

    by Monique J. Windley, Jessica Farr, Clifford TeBay, Jamie I. Vandenberg, Adam P. Hill


  • Open Access

    Metabolic and electrolyte abnormalities as risk factors in drug-induced long QT syndrome

    by Clifford TeBay, Adam P. Hill, Monique J. Windley

    Drug-induced long QT syndrome (diLQTS) is the phenomenon by which the administration of drugs causes prolongation of cardiac repolarisation and leads to an increased risk of the ventricular tachycardia known as torsades de pointes (TdP). In most cases of diLQTS, the primary molecular target is the human ether-à-go-go-related gene protein (hERG) potassium channel, which carries the rapid delayed rectifier current (IKr) in the heart. However, the proarrhythmic risk associated with drugs that block hERG can be modified in patients by a range of environmental- and disease-related factors, such as febrile temperatures, alterations in pH, dyselectrolytaemias such as hypokalaemia and hypomagnesemia and coadministration with other drugs. In this review, we will discuss the clinical occurrence of drug-induced LQTS in the context of these modifying factors as well as the mechanisms by which they contribute to altered hERG potency and proarrhythmic risk.


  • Open Access

    A nonlinear and time-dependent leak current in the presence of calcium fluoride patch-clamp seal enhancer

    by Chon Lok Lei, Alan Fabbri, Dominic G. Whittaker, Michael Clerx, Monique J. Windley, Adam P. Hill, Gary R. Mirams, Teun P. de Boer

    Automated patch-clamp platforms are widely used and vital tools in both academia and industry to enable high-throughput studies such as drug screening. A leak current to ground occurs whenever the seal between a pipette and cell (or internal solution and cell in high-throughput machines) is not perfectly insulated from the bath (extracellular) solution. Over 1 GΩ seal resistance between pipette and bath solutions is commonly used as a quality standard for manual patch work. With automated platforms it can be difficult to obtain such a high seal resistance between the intra- and extra-cellular solutions. One suggested method to alleviate this problem is using an F− containing internal solution together with a Ca2+ containing external solution — so that a CaF2 crystal forms when the two solutions meet which ‘plugs the holes’ to enhance the seal resistance. However, we observed an unexpected nonlinear-in-voltage and time-dependent current using these solutions on an automated patch-clamp platform. We performed manual patch-clamp experiments with the automated patch-clamp solutions, but no biological cell, and observed the same nonlinear time-dependent leak current. The current could be completely removed by washing out F− ions to leave a conventional leak current that was linear and not time-dependent. We therefore conclude fluoride ions interacting with the CaF2 crystal are the origin of the nonlinear time-dependent leak current. The consequences of such a nonlinear and time-dependent leak current polluting measurements should be considered carefully if it cannot be isolated and subtracted.