Design and In Vivo Verification of a CMOS Bone-Guided Cochlear Implant Microsystem
Authors:
- Xin-Hong QianXQXin-Hong Qian
- Yu-Chi LeeYLYu-Chi Lee
- Jia-Heng ChangJCJia-Heng Chang
- Shih-Ting LinSLShih-Ting Lin
- Shang-Hsuan LiSLShang-Hsuan Li
- Tsung-Chen WuTWTsung-Chen Wu
- Chien-Chang HuangCHChien-Chang Huang
- Sung-Hao WangSWSung-Hao Wang
- Chia-Fone LeeCLChia-Fone Lee
- Chia-Hsiang YangCYChia-Hsiang Yang
- Chung-Chih HungChung-Chih Hung
- Yi-Chung WuYWYi-Chung Wu
- 25 February 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (11) , 3156-3167
Abstract
Objective: To develop and verify a CMOS bone-guided cochlear implant (BGCI) microsystem with electrodes placed on the bone surface of the cochlea and the outside of round window for treating high-frequency hearing loss. Methods: The BGCI microsystem consists of an external unit and an implanted unit. The external system-on-chip (SOC) is designed to process acoustic signals through an acquisition circuit and an acoustic DSP processor to generate stimulation patterns and commands that are transmitted to the implanted unit through a 13.56 MHz wireless power and bidirectional data telemetry. In the wireless power te-lemetry, a voltage doubler/tripler (2X/3X) active rectifier is used to enhance the power conversion efficiency and generate 2 V and 3 V output voltages. In the wireless data telemetry, phase-locked loop (PLL) based binary phase-shift keying (BPSK) and load-shift keying (LSK) modulators/demodulators are adopted for the down-link and uplink data through high-Q coils, respectively. The im-planted chip with 4-channel high-voltage-tolerant stimulator gen-erates biphasic stimulation currents up to 800 μA. Results: Electri-cal tests on the fabricated BGCI microsystem has been performed to verify the chip functions. The in-vivo animal tests in guinea pigs have shown the evoked third wave (Wave eIII) of electrically evoked auditory brainstem response (EABR) waveforms. It is ver-ified that auditory nerves can be successfully stimulated and acoustic hearing can be partially preserved. Conclusion and Significance: Different from traditional cochlear implants, the pro-posed BGCI microsystem is less invasive, preserves partially acoustic hearing, and provides an effective alternative to treating high-frequency hearing loss.Keywords
Funding Information
- Center for Neuromodulation Medical Electronics Systems
- Ministry of Education in Taiwan
- Ministry of Science and Technology, Taiwan (MOST-106-2221-E-009-160-MY2)
This publication has 25 references indexed in Scilit:
- Effect of enhancement of spectral changes on speech intelligibility and clarity preferences for the hearing impairedThe Journal of the Acoustical Society of America, 2012
- Registration of Micro-Computed Tomography and Histological Images of the Guinea Pig Cochlea to Construct an Ear Model Using an Iterative Closest Point AlgorithmAnnals of Biomedical Engineering, 2010
- The Electrochemistry of Charge Injection at the Electrode/Tissue Interface2010
- Cochlear implantation in rats: A new surgical approachHearing Research, 2005
- Analog-to-digital converter survey and analysisIEEE Journal on Selected Areas in Communications, 1999
- Temporal information in speech: acoustic, auditory and linguistic aspectsPhilosophical Transactions of the Royal Society B: Biological Sciences, 1992
- Better speech recognition with cochlear implantsNature, 1991
- Class E Power Amplifiers and Frequency Multipliers with finite DC-Feed InductanceIEEE Transactions on Circuits and Systems, 1987
- Characterization of the electrically evoked auditory brainstem response (ABR) in cats and humansHearing Research, 1986
- Suggested formulae for calculating auditory-filter bandwidths and excitation patternsThe Journal of the Acoustical Society of America, 1983