Abstract
Externally bonded fiber-reinforced polymer (FRP) composites are becoming a method of choice for the repair/strengthening of civil structures, some of which are situated in environments detrimental to FRP-concrete bond durability. Based on analysis of an extensive database of durability test results from notched-beam three-point bending tests, a bond durability factor (BDF) of 0.60 was identified as an appropriate estimate of bond durability for wet-layup carbon fiber-reinforced polymer (CFRP). This factor was compared to a normalized database of durability data from the literature, and it was found that a 0.60 BDF agrees well with these data. A modified procedure for determining the ultimate design strain primarily in bond-critical applications (such as external flexural and shear FRP reinforcement), is proposed. This procedure makes a distinction between durability properties associated with the FRP rupture and debonding failure modes. When used for practically feasible strengthening ratios and i...