Impact of Cup Anteversion and Hip-Spine Relationship on Femoral Neck Notching in Dual Mobility Total Hip Arthroplasty
Authors:
- Yuto KawamuraYKYuto Kawamura
- Tomonori BabaTBTomonori Baba
- Masashi NagaoMNMasashi Nagao
- Ken TashiroKTKen Tashiro
- Ryuji OkunoRORyuji Okuno
- Eiji IwasakiEIEiji Iwasaki
- Fumihiro MukasaFMFumihiro Mukasa
- Koju HayashiKHKoju Hayashi
- Yasuhiro HommaYHYasuhiro Homma
- Taiji WatariTWTaiji Watari
- Kazuo KanekoKKKazuo Kaneko
- Muneaki IshijimaMIMuneaki Ishijima
Open Access
- 1 January 2026
- journal article
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 11 (1)
Abstract
Background: Dual-mobility cups (DMCs) are increasingly used in total hip arthroplasty (THA) because of their low dislocation rates. However, a unique complication associated with DMCs is femoral neck notching (FNN), which is believed to result from impingement between the metal liner and the femoral stem neck. The risk factors for FNN, however, remain poorly understood. This study aimed to identify the risk factors associated with FNN in patients undergoing THA with DMCs. Methods: This retrospective analysis included 766 patients who underwent THA with DMCs between 2013 and 2023. Patients with follow-up durations of less than 1 year and those with mixed-manufacturer components (i.e., an acetabular cup and a femoral stem from different manufacturers) were excluded. Cup positioning angles and the presence of FNN were assessed using standard radiographs. Spinopelvic alignment was evaluated in a subgroup of 204 patients using EOS imaging. Results: FNN was identified in 24 of 766 patients (3.1%). Among these, 14 patients underwent EOS imaging, compared with 190 patients without FNN. Patients with FNN demonstrated significantly higher cup anteversion (31.4° ± 6.1°) than those without FNN (15.2° ± 4.8°, p < 0.0001). Logistic regression analysis showed that increased cup anteversion was significantly associated with FNN, with an odds ratio of 1.62 (95% confidence interval: 1.32-2.27, p < 0.0001), identifying it as the primary risk factor for FNN formation. Conclusions: Cup anteversion was identified as a significant risk factor for FNN following THA with DMCs. These findings suggest that careful attention to cup positioning may help reduce the incidence of FNN in DMC-THA. Level of Evidence: Prognostic Level IV . See Instructions for Authors for a complete description of levels of evidence.Keywords
This publication has 32 references indexed in Scilit:
- Metal Ion Levels in Young, Active Patients Receiving a Modular, Dual Mobility Total Hip ArthroplastyThe Journal of Arthroplasty, 2017
- Low friction arthroplasty and dual mobility cup: a new gold standardInternational Orthopaedics, 2016
- Serum Metal Ion Levels Following Total Hip Arthroplasty With Modular Dual Mobility ComponentsThe Journal of Arthroplasty, 2016
- Cup Position Alone Does Not Predict Risk of Dislocation After Hip ArthroplastyThe Journal of Arthroplasty, 2015
- Notching of the Femoral Stem Neck in Metal-on-Metal Total Hip Replacement: A Case ReportJournal of Orthopaedic Surgery, 2013
- Corrosion at the Head-Neck Taper as a Cause for Adverse Local Tissue Reactions After Total Hip ArthroplastyJournal of Bone and Joint Surgery, 2012
- Catastrophic Failure of a Metal-on-Metal Total Hip Arthroplasty Secondary to Metal Inlay DissociationThe Journal of Arthroplasty, 2011
- Dislocation After Total Hip Arthroplasty Using Hueter Anterior ApproachThe Journal of Arthroplasty, 2008
- A New Tool for Measuring Cup Orientation in Total Hip Arthroplasties from Plain RadiographsClinical Orthopaedics and Related Research, 2006
- A simplified method to determine acetabular cup anteversion from plain radiographsThe Journal of Arthroplasty, 2004