TWTaiji Watari

Taiji Watari

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Taiji Watari has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Intraoperative six-axis loads during direct anterior approach total hip arthroplasty using a leg positioner: quantitative patterns across manoeuvres

    by Eiji Iwasaki, Tomonori Baba, Ken Tashiro, Koju Hayashi, Taiji Watari, Risa Shoji, Akihiko Hanafusa, Muneaki Ishijima

    Purpose The direct anterior approach (DAA) for total hip arthroplasty (THA) commonly uses leg positioners to facilitate femoral exposure, but intraoperative lower-limb loading during these manoeuvres remains poorly understood. This study quantitatively assessed six-axis loads during femoral preparation in leg positioner-assisted DAA-THA. Methods This prospective observational biomechanical study included 95 hips undergoing primary DAA-THA using a leg positioner. A six-axis force sensor mounted on the operative boot recorded forces (Fx, Fy, Fz) and moments (Mx, My, Mz) at baseline and at two predefined static endpoint measurement points: the extension endpoint and the final stem position after adduction. Values were expressed relative to baseline and represented static endpoint measurements rather than peak values during dynamic manoeuvres. Measurements were standardised to a right-sided coordinate system. Repeated-measures analysis of variance with Bonferroni-corrected post hoc paired comparisons was used. Results At the extension endpoint, distal traction force was greatest (Fz; 170.6 ± 51.9 N). At the final stem position after adduction, distal traction force decreased compared with the extension endpoint but remained elevated relative to baseline (126.9 ± 45.7 N), and Mx showed the greatest magnitude among the moment components. The maximum endpoint Fz relative to baseline was recorded at the extension endpoint (322.8 N). No significant associations were found between final-position Fz and age, sex, height, weight, body mass index, or diagnosis. Mean stem rasping time was 10 min 48 s ± 4 min 28 s (648 ± 268 s). Conclusion During leg positioner-assisted DAA-THA, the extension endpoint generated the highest distal traction force, whereas the final stem position after adduction was associated with residual distal traction force and a greater magnitude of Mx.

  • Open Access

    Impact of Cup Anteversion and Hip-Spine Relationship on Femoral Neck Notching in Dual Mobility Total Hip Arthroplasty

    by Yuto Kawamura, Tomonori Baba, Masashi Nagao, Ken Tashiro, Ryuji Okuno, Eiji Iwasaki, Fumihiro Mukasa, Koju Hayashi, Yasuhiro Homma, Taiji Watari, et al.

    Background: Dual-mobility cups (DMCs) are increasingly used in total hip arthroplasty (THA) because of their low dislocation rates. However, a unique complication associated with DMCs is femoral neck notching (FNN), which is believed to result from impingement between the metal liner and the femoral stem neck. The risk factors for FNN, however, remain poorly understood. This study aimed to identify the risk factors associated with FNN in patients undergoing THA with DMCs. Methods: This retrospective analysis included 766 patients who underwent THA with DMCs between 2013 and 2023. Patients with follow-up durations of less than 1 year and those with mixed-manufacturer components (i.e., an acetabular cup and a femoral stem from different manufacturers) were excluded. Cup positioning angles and the presence of FNN were assessed using standard radiographs. Spinopelvic alignment was evaluated in a subgroup of 204 patients using EOS imaging. Results: FNN was identified in 24 of 766 patients (3.1%). Among these, 14 patients underwent EOS imaging, compared with 190 patients without FNN. Patients with FNN demonstrated significantly higher cup anteversion (31.4° ± 6.1°) than those without FNN (15.2° ± 4.8°, p < 0.0001). Logistic regression analysis showed that increased cup anteversion was significantly associated with FNN, with an odds ratio of 1.62 (95% confidence interval: 1.32-2.27, p < 0.0001), identifying it as the primary risk factor for FNN formation. Conclusions: Cup anteversion was identified as a significant risk factor for FNN following THA with DMCs. These findings suggest that careful attention to cup positioning may help reduce the incidence of FNN in DMC-THA. Level of Evidence: Prognostic Level IV . See Instructions for Authors for a complete description of levels of evidence.

  • Weak hammering sounds are associated with postoperative subsidence in cementless total hip arthroplasty

    by Yasuhiro Homma, Ken Tashiro, Ryuji Okuno, Masashi Unoki, Yuki Murakami, Taiji Watari, Tomonori Baba, Muneaki Ishijima

    Purpose The aim of this study was to investigate the relationship between the hammering sound level and the presence of postoperative subsidence. Methods The last five hammering sounds during the final-size broaching procedure and during the real stem insertion were recorded and analysed in 95 patients who were operated on by one of seven surgeons using two implants (Trident cup, Accolade II, Stryker; G7 cup, Taperloc Complete Microplasty Stem, Zimmer Biomet). The maximum peak was semi-automatically identified and analysed to determine the maximum C-weighted sound pressure level (LCpeak) of each of the five hammering sounds and the equivalent continuous A-weighted sound pressure (LAeq) of the entire five-sound hammering procedure. Results Among the 95 hips, 25 (26.3%) had ≥ 3 mm of postoperative subsidence. Therefore, 125 of 475 hammering sounds (LCpeak) and 25 of 95 hammering procedures (LAeq) in both the broaching procedure and stem insertion procedure were associated with postoperative subsidence. The hammering sound level in both the broaching and stem insertion procedures were significantly weaker in patients with postoperative subsidence than in those without subsidence. Among the seven surgeons, there was intra-surgeon and inter-surgeon heterogeneity with large variance regarding the sound levels. With univariate and multivariate analyses, the hammering sound level was independently associated with postoperative subsidence in the two models. Conclusion A weak hammering sound level was associated with postoperative subsidence in THA with a cementless stem. An objective evaluation of the hammering procedure might be useful to decrease the incidence of postoperative subsidence.


  • Open Access

    Differences in acoustic parameters of hammering sounds between successful and unsuccessful initial cementless cup press-fit fixation in total hip arthroplasty

    by Yasuhiro Homma, Xu Zhuang, Taiji Watari, Koju Hayashi, Tomonori Baba, Atul Kamath, Muneaki Ishijima

    Differences in acoustic parameters of hammering sounds between successful and unsuccessful initial cementless cup press-fit fixation in total hip arthroplasty