Structural and nonstructural performance of a seismically isolated building using stable unbonded fiber‐reinforced elastomeric isolators
- 19 October 2015
- journal article
- research article
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 45 (3) , 421-439
Abstract
Summary: Stable unbonded fiber‐reinforced elastomeric isolators (SU‐FREIs) exhibit a characteristic horizontal softening and stiffening response, similar to other adaptive devices such as the triple friction pendulum and sliding systems with variable curvature. The transition between the softening and stiffening occurs at a displacement corresponding to a unique deformation known as full rollover. In this paper, the full rollover displacement of SU‐FREIs is altered by using modified support geometry (MSG), a geometric modification of the upper and lower supports applied to tailor the hysteresis loops of the isolator. Experimental results are used to calibrate a numerical model of a base‐isolated structure. The model demonstrates that the stiffening regime provides minimal restraint against displacements during events that meet or exceed the maximum considered earthquake. A parametric study revealed that the level of stiffening required to restrain displacements during large events is significant. This increase in stiffness is reflected in an increase in the response of the structure and light nonstructural components. Full rollover and MSG is considered advantageous to maintain horizontal stability and provide control over the stiffening of SU‐FREIs. Copyright © 2015 John Wiley & Sons, Ltd.Keywords
Funding Information
- McMaster University Centre for Effective Design of Structures (CEDS)
This publication has 34 references indexed in Scilit:
- Full‐scale shaking table test of a base‐isolated medical facility subjected to vertical motionsEarthquake Engineering & Structural Dynamics, 2013
- Approximating peak responses in seismically isolated buildings using generalized modal analysisEarthquake Engineering & Structural Dynamics, 2013
- Experimental simulation of base‐isolated buildings pounding against moat wall and effects on superstructure responseEarthquake Engineering & Structural Dynamics, 2012
- Bonded versus unbonded strip fiber reinforced elastomeric isolators: Finite element analysisComposite Structures, 2011
- Simplified analysis of a low-rise building seismically isolated with stable unbonded fiber reinforced elastomeric isolatorsCanadian Journal of Civil Engineering, 2009
- Parametric Study on the Response of Stable Unbonded-Fiber Reinforced Elastomeric Isolators (SU-FREIs)Journal of Composite Materials, 2009
- Simulation of the earthquake-induced pounding of seismically isolated buildingsComputers & Structures, 2008
- A review of adverse effects of damping in seismic isolationEarthquake Engineering & Structural Dynamics, 2007
- Testing and modeling of square carbon fiber-reinforced elastomeric seismic isolatorsStructural Control and Health Monitoring, 2007
- Spherical sliding isolation bearings with adaptive behavior: TheoryEarthquake Engineering & Structural Dynamics, 2007