Separation of proteins by cation-exchange sequential injection chromatography using a polymeric monolithic column
- 16 December 2015
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 408 (5) , 1445-1452
Abstract
Since sequential injection chromatography (SIC) emerged in 2003, it has been used for separation of small molecules in diverse samples, but separations of high molar mass compounds such as proteins have not yet been described. In the present work a poly(glycidyl methacrylate-co-ethylene dimethacrylate) (GMA-co-EDMA) monolithic column was prepared by free radical polymerization inside a 2.1-mm-i.d. activated fused silica-lined stainless steel tubing and modified with iminodiacetic acid (IDA). The column was prepared from a mixture of 24 % GMA, 16 % EDMA, 20 % cyclohexanol, and 40 % 1-dodecanol (all % as w/w) containing 1 % of azobisisobutyronitrile (AIBN) (in relation to monomers). Polymerization was done at 60 °C for 24 h. The polymer was modified with 1.0 M IDA (in 2 M Na2CO3, pH 10.5) at 80 °C for 16 h. Separation of myoglobin, ribonuclease A, cytochrome C, and lysozyme was achieved at pH 7.0 (20 mM KH2PO4/K2HPO4) using a salt gradient (NaCl). Myoglobin was not retained, and the other proteins were separated by a gradient of NaCl created inside the holding coil (4 m of 0.8-mm-i.d. PTFE tubing) by sequential aspiration of 750 and 700 μL of 0.2 and 0.1 M NaCl, respectively. As the flow was reversed toward the column (5 μL s−1) the interdispersion of these solutions created a reproducible gradient which separated the proteins in 10 min, with the following order of retention: ribonuclease A < cytochrome C < lysozyme. The elution order was consistent with a cation-exchange mechanism as the retention increased with the isoelectric points.Keywords
This publication has 33 references indexed in Scilit:
- Sequential Injection Chromatography with post-column reaction/derivatization for the determination of transition metal cations in natural water samplesTalanta, 2015
- Evaluation of sequential injection chromatography for reversed phase separation of triazine herbicides exploiting monolithic and core–shell columnsTalanta, 2015
- The Second Five Years of Sequential Injection Chromatography: Significant Developments in the Technology and MethodologiesCritical Reviews in Analytical Chemistry, 2014
- Monolithic columns in plant proteomics and metabolomicsAnalytical and Bioanalytical Chemistry, 2012
- High-resolution monolithic columns—a new tool for effective and quick separationAnalytical and Bioanalytical Chemistry, 2012
- Enhanced capabilities of separation in Sequential Injection Chromatography – Fused-core particle column and its comparison with narrow-bore monolithic columnTalanta, 2011
- Contribution of multi-commuted flow analysis combined with monolithic columns to low-pressure, high-performance chromatographyTrAC Trends in Analytical Chemistry, 2009
- Development of a continuous protein and polysaccharide measurement method by Sequential Injection Analysis for application in membrane bioreactor systemsWater Science & Technology, 2007
- An overview of sequential injection chromatographyAnalytica Chimica Acta, 2007
- Coupling of monolithic columns with sequential injection techniqueAnalytica Chimica Acta, 2003