Electrical performance of composite insulators under icing conditions
Authors:
- 1 December 2014
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 21 (6) , 2584-2593
Abstract
Due to the substantial advantage compared to porcelain and glass insulators, Composite insulators have been widely accepted in electric power utilities worldwide. Compared with porcelain and glass insulators, the flashover performance of composite insulators is superior under the contaminated condition, whereas their icing flashover performance should be investigated further. As shown in previous studies, many factors influence the flashover performance of composite insulators under icing conditions. In order to figure out the factors that influence the flashover performance of insulators, experiments were carried out on icecovered energized and de-energized composite insulators under icing condition. The results show that the flashover performances of composite insulators are superior under energized condition compared with de-energized condition. Under energized condition, when icing is light, the flashover performance of different shed configurations is decided by creepage distance. When icing is moderate, the flashover performance of insulator is influenced by water freezing conductivity, shed configuration, creepage factor, and so on. When icing is heavy, most of the sheds are bridged and the configuration of the last few sheds near the high voltage end have important effect on the flashover performance.Keywords
This publication has 17 references indexed in Scilit:
- Mechanism of salt migration in icicles during phase transition and its impact on ice flashoverIEEE Transactions on Dielectrics and Electrical Insulation, 2012
- Influence of air gaps on the DC withstand voltage of ice-covered UHV insulators2012
- Effects of shed configuration on AC flashover performance of ice-covered composite long-rod insulatorsIEEE Transactions on Dielectrics and Electrical Insulation, 2012
- Equivalence of Influence of Pollution Simulating Methods on DC Flashover Stress of Ice-Covered InsulatorsIEEE Transactions on Power Delivery, 2009
- Role of air gaps on AC withstand voltage of an ice-covered insulator stringIEEE Transactions on Dielectrics and Electrical Insulation, 2006
- Effect of insulator diameter on AC flashover voltage of an ice-covered insulator stringIEEE Transactions on Dielectrics and Electrical Insulation, 2006
- AC flashover performance and voltage of long polluted and iced XP-70 suspension insulator string2004
- An experimental study of flashover performance of various post insulators under icing conditions2002
- AC flashover performance of insulators covered with artificial iceIEEE Transactions on Power Delivery, 1995
- Flashover test of Artificially iced InsualtorsIEEE Transactions on Power Apparatus and Systems, 1982