Indirect X-ray detectors with single-photon sensitivity
Open Access
- 25 October 2022
- journal article
- research article
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (6) , 1394-1406
Abstract
The new generation of synchrotron light sources are pushing X-ray detectors to their limits. Very demanding conditions with unprecedented flux and higher operating energies now require high-performance X-ray detectors combining sensitivity, efficiency and scalability. Over the years, hybrid pixel detectors have supplemented indirect detectors based on scintillation, with undeniable advantages. Such detectors based on silicon are, however, rather expensive to produce and are no more satisfying in terms of X-ray stopping power when targeting energies above 20 keV. An indirect detector with single X-ray photon sensitivity therefore offers promising opportunities for applications operating over a wide range of energies and fluxes. In this work, the performances of such an approach are investigated with state-of-the-art elements: a commercial sCMOS camera with fiber-optics plate coupling and a Gd2O2S:Tb powder-based scintillator. A simple method is presented for evaluation of the single X-ray photon detection limit and single X-ray sensitivity is demonstrated with the studied detector above 20 keV. Geant4 simulations also provide insight to better define the limiting factors. Finally, guidelines are provided for future R&D in the design and assembly of an innovative detector combining advantages of direct and indirect detection schemes.Keywords
Funding Information
- European Synchrotron Radiation Facility
This publication has 33 references indexed in Scilit:
- EMVA 1288 Standard for Machine VisionOptik & Photonik, 2010
- X-rays2006
- Synthesis and characterisation of rare earth oxysulphide phosphors. I. Studies on the preparation of Gd2O2S:Tb phosphor by the flux methodOptical Materials, 2004
- Quantitative X‐ray projection microscopy: phase‐contrast and multi‐spectral imagingJournal of Microscopy, 2002
- Quantitative In-Line Phase-Contrast Imaging with Multienergy X RaysPhysical Review Letters, 2001
- A method for measuring the presampled MTF of digital radiographic systems using an edge test deviceMedical Physics, 1998
- Modulation transfer function evaluation of linear solid-state x-ray-sensitive detectors using edge techniquesApplied Optics, 1995
- Absorption and noise in x-ray phosphorsJournal of Applied Physics, 1973
- X-Ray Efficiency of Powder PhosphorsJournal of the Electrochemical Society, 1971
- Random Noise Produced by X-Ray Fluorescent Screens*Journal of the Optical Society of America, 1968