Kristof Pauwels
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Kristof Pauwels has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
- Stefan Gundacker
Marietta Blau Institute, Austrian Academy of Sciences, Vienna, Austria
5 shared publications E. Auffray
European Organization for Nuclear Research
4 shared publications- Etiennette Auffray
CERN
4 shared publications - Paul Lecoq
CERN
4 shared publications - Christophe Dujardin
Institut Lumière Matière Université Claude Bernard Lyon 1 CNRS Villeurbanne France
3 shared publications - Marco Pizzichemi
INFN Sezione di Milano-Bicocca
3 shared publications
Latest Publications
- 1 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Inorganic single crystalline fibers for dual-readout calorimetry
Étude de fibres inorganiques monocrystallines en calorimétrie à double lecture: L'amélioration de la résolution en énergie des calorimètres hadroniques est adressée dans cette thèse. L'approche envisagée se base sur la technique du dual-readout qui consiste à détecter simultanément les radiations Cherenkov et la scintillation. La comparaison de ces deux signaux permet en effet de compenser les fluctuations observées dans la détection de gerbes hadroniques. Les grenats d'Aluminium et de Lutetium (LuAG), qui sont d'efficaces scintillateurs une fois activés avec des terres rares, peuvent aussi jouer le rôle de radiateur Cherenkov sous leur forme non-dopée. Les deux types de matériaux peuvent alors être assemblés pour former un calorimètre dual-readout performant. Dans l'objectif d'étudier la faisabilité de ce concept, les effets de la concentration en dopant et de l'addition de divers codopants sur le rendement lumineux et les propriétés temporelles ont été étudiés. Nous avons montré le rôle important de la technique de croissance choisie sur la nature et la concentration des défauts structuraux. La géométrie optimale, qui se base sur des monocristaux en forme de fibres, donne l'avantage à la technique de micro-pulling down. Cette technologie ne montre pas de meilleurs résultats que les techniques de Bridgman et de Czochralski mais a été retenue pour des raisons de coût et d'adaptabilité pour une production à grande échelle. L'optimisation des paramètres de croissance a permis la production de fibres monocristallines de LuAG dopées avec du Cérium présentant un rendement lumineux de 8000 photons par MeV et un bon comportement en tant que guide de lumière grâce à une qualité optique bien maitrisée. Des tests avec des faisceaux d'électrons et de pions, en conditions de calorimétrie à haute énergie, permettent désormais d'envisager la production d'un prototype à plus grande échelle
- 1 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Inorganic single crystalline fibers for dual-readout calorimetry
Étude de fibres inorganiques monocrystallines en calorimétrie à double lecture: L'amélioration de la résolution en énergie des calorimètres hadroniques est adressée dans cette thèse. L'approche envisagée se base sur la technique du dual-readout qui consiste à détecter simultanément les radiations Cherenkov et la scintillation. La comparaison de ces deux signaux permet en effet de compenser les fluctuations observées dans la détection de gerbes hadroniques. Les grenats d'Aluminium et de Lutetium (LuAG), qui sont d'efficaces scintillateurs une fois activés avec des terres rares, peuvent aussi jouer le rôle de radiateur Cherenkov sous leur forme non-dopée. Les deux types de matériaux peuvent alors être assemblés pour former un calorimètre dual-readout performant. Dans l'objectif d'étudier la faisabilité de ce concept, les effets de la concentration en dopant et de l'addition de divers codopants sur le rendement lumineux et les propriétés temporelles ont été étudiés. Nous avons montré le rôle important de la technique de croissance choisie sur la nature et la concentration des défauts structuraux. La géométrie optimale, qui se base sur des monocristaux en forme de fibres, donne l'avantage à la technique de micro-pulling down. Cette technologie ne montre pas de meilleurs résultats que les techniques de Bridgman et de Czochralski mais a été retenue pour des raisons de coût et d'adaptabilité pour une production à grande échelle. L'optimisation des paramètres de croissance a permis la production de fibres monocristallines de LuAG dopées avec du Cérium présentant un rendement lumineux de 8000 photons par MeV et un bon comportement en tant que guide de lumière grâce à une qualité optique bien maitrisée. Des tests avec des faisceaux d'électrons et de pions, en conditions de calorimétrie à haute énergie, permettent désormais d'envisager la production d'un prototype à plus grande échelle
- 3 February 2024
- Published by Elsevier in Optical Materials
- Vol. 149
Micro-patterning of scintillating films by Liquid Phase Epitaxy: A proof of concept
- 3 February 2024
- Published by Elsevier in Optical Materials
- Vol. 149
Micro-patterning of scintillating films by Liquid Phase Epitaxy: A proof of concept
- Open Access
- 28 August 2023
- Published by American Chemical Society (ACS) in ACS Energy Letters
- Vol. 8 (9) , 3883-3894
Ultrafast and Radiation-Hard Lead Halide Perovskite Nanocomposite Scintillators
The use of scintillators for the detection of ionizing radiation is a critical aspect in many fields, including medicine, nuclear monitoring, and homeland security. Recently, lead halide perovskite nanocrystals (LHP-NCs) have emerged as promising scintillator materials. However, the difficulty of affordably upscaling synthesis to the multigram level and embedding NCs in optical-grade nanocomposites without compromising their optical properties still limits their widespread use. In addition, fundamental aspects of the scintillation mechanisms are not fully understood, leaving the scientific community without suitable fabrication protocols and rational guidelines for the full exploitation of their potential. In this work, we realize large polyacrylate nanocomposite scintillators based on CsPbBr3 NCs, which are synthesized via a novel room temperature, low waste turbo-emulsification approach, followed by their in situ transformation during the mass polymerization process. The interaction between NCs and polymer chains strengthens the scintillator structure, homogenizes the particle size distribution and passivates NC defects, resulting in nanocomposite prototypes with luminescence efficiency >90%, exceptional radiation hardness, 4800 ph/MeV scintillation yield even at low NC loading, and ultrafast response time, with over 30% of scintillation occurring in the first 80 ps, promising for fast-time applications in precision medicine and high-energy physics. Ultrafast radioluminescence and optical spectroscopy experiments using pulsed synchrotron light further disambiguate the origin of the scintillation kinetics as the result of charged-exciton and multiexciton recombination formed under ionizing excitation. This highlights the role of nonradiative Auger decay, whose potential impact on fast timing applications we anticipate via a kinetic model.
- 28 August 2023
- Published by American Chemical Society (ACS) in ACS Energy Letters
- Vol. 8 (9) , 3883-3894
Open AccessUltrafast and Radiation-Hard Lead Halide Perovskite Nanocomposite Scintillators
The use of scintillators for the detection of ionizing radiation is a critical aspect in many fields, including medicine, nuclear monitoring, and homeland security. Recently, lead halide perovskite nanocrystals (LHP-NCs) have emerged as promising scintillator materials. However, the difficulty of affordably upscaling synthesis to the multigram level and embedding NCs in optical-grade nanocomposites without compromising their optical properties still limits their widespread use. In addition, fundamental aspects of the scintillation mechanisms are not fully understood, leaving the scientific community without suitable fabrication protocols and rational guidelines for the full exploitation of their potential. In this work, we realize large polyacrylate nanocomposite scintillators based on CsPbBr3 NCs, which are synthesized via a novel room temperature, low waste turbo-emulsification approach, followed by their in situ transformation during the mass polymerization process. The interaction between NCs and polymer chains strengthens the scintillator structure, homogenizes the particle size distribution and passivates NC defects, resulting in nanocomposite prototypes with luminescence efficiency >90%, exceptional radiation hardness, 4800 ph/MeV scintillation yield even at low NC loading, and ultrafast response time, with over 30% of scintillation occurring in the first 80 ps, promising for fast-time applications in precision medicine and high-energy physics. Ultrafast radioluminescence and optical spectroscopy experiments using pulsed synchrotron light further disambiguate the origin of the scintillation kinetics as the result of charged-exciton and multiexciton recombination formed under ionizing excitation. This highlights the role of nonradiative Auger decay, whose potential impact on fast timing applications we anticipate via a kinetic model.
- Open Access
- 12 June 2023
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 56 (4) , 1032-1037
Bragg coherent diffraction imaging with the CITIUS charge-integrating detector
The CITIUS detector is a next-generation high-speed X-ray imaging detector. It has integrating-type pixels and is designed to show a consistent linear response at a frame rate of 17.4 kHz, which results in a saturation count rate of over 30 Mcps pixel−1 when operating at an acquisition duty cycle close to 100%, and up to 20 times higher with special extended acquisition modes. Here, its application for Bragg coherent diffraction imaging is demonstrated by taking advantage of the fourth-generation Extremely Brilliant Source of the European Synchrotron (ESRF-EBS, Grenoble, France). The CITIUS detector outperformed a photon-counting detector, similar spatial resolution being achieved (20 ± 6 nm versus 22 ± 9 nm) with greatly reduced acquisition times (23 s versus 200 s). It is also shown how the CITIUS detector can be expected to perform during dynamic Bragg coherent diffraction imaging measurements. Finally, the current limitations of the CITIUS detector and further optimizations for coherent imaging techniques are discussed.
- 12 June 2023
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 56 (4) , 1032-1037
Open AccessBragg coherent diffraction imaging with the CITIUS charge-integrating detector
The CITIUS detector is a next-generation high-speed X-ray imaging detector. It has integrating-type pixels and is designed to show a consistent linear response at a frame rate of 17.4 kHz, which results in a saturation count rate of over 30 Mcps pixel−1 when operating at an acquisition duty cycle close to 100%, and up to 20 times higher with special extended acquisition modes. Here, its application for Bragg coherent diffraction imaging is demonstrated by taking advantage of the fourth-generation Extremely Brilliant Source of the European Synchrotron (ESRF-EBS, Grenoble, France). The CITIUS detector outperformed a photon-counting detector, similar spatial resolution being achieved (20 ± 6 nm versus 22 ± 9 nm) with greatly reduced acquisition times (23 s versus 200 s). It is also shown how the CITIUS detector can be expected to perform during dynamic Bragg coherent diffraction imaging measurements. Finally, the current limitations of the CITIUS detector and further optimizations for coherent imaging techniques are discussed.
- Open Access
- 25 October 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (6) , 1394-1406
Indirect X-ray detectors with single-photon sensitivity
The new generation of synchrotron light sources are pushing X-ray detectors to their limits. Very demanding conditions with unprecedented flux and higher operating energies now require high-performance X-ray detectors combining sensitivity, efficiency and scalability. Over the years, hybrid pixel detectors have supplemented indirect detectors based on scintillation, with undeniable advantages. Such detectors based on silicon are, however, rather expensive to produce and are no more satisfying in terms of X-ray stopping power when targeting energies above 20 keV. An indirect detector with single X-ray photon sensitivity therefore offers promising opportunities for applications operating over a wide range of energies and fluxes. In this work, the performances of such an approach are investigated with state-of-the-art elements: a commercial sCMOS camera with fiber-optics plate coupling and a Gd2O2S:Tb powder-based scintillator. A simple method is presented for evaluation of the single X-ray photon detection limit and single X-ray sensitivity is demonstrated with the studied detector above 20 keV. Geant4 simulations also provide insight to better define the limiting factors. Finally, guidelines are provided for future R&D in the design and assembly of an innovative detector combining advantages of direct and indirect detection schemes.
- 25 October 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (6) , 1394-1406
Open AccessIndirect X-ray detectors with single-photon sensitivity
The new generation of synchrotron light sources are pushing X-ray detectors to their limits. Very demanding conditions with unprecedented flux and higher operating energies now require high-performance X-ray detectors combining sensitivity, efficiency and scalability. Over the years, hybrid pixel detectors have supplemented indirect detectors based on scintillation, with undeniable advantages. Such detectors based on silicon are, however, rather expensive to produce and are no more satisfying in terms of X-ray stopping power when targeting energies above 20 keV. An indirect detector with single X-ray photon sensitivity therefore offers promising opportunities for applications operating over a wide range of energies and fluxes. In this work, the performances of such an approach are investigated with state-of-the-art elements: a commercial sCMOS camera with fiber-optics plate coupling and a Gd2O2S:Tb powder-based scintillator. A simple method is presented for evaluation of the single X-ray photon detection limit and single X-ray sensitivity is demonstrated with the studied detector above 20 keV. Geant4 simulations also provide insight to better define the limiting factors. Finally, guidelines are provided for future R&D in the design and assembly of an innovative detector combining advantages of direct and indirect detection schemes.
- Open Access
- 23 November 2017
- Published by Springer Nature
- p. 231-241
Calorimeter Designs Based on Fibre-Shaped Scintillators
- 23 November 2017
- Published by Springer Nature
- p. 231-241
Open AccessCalorimeter Designs Based on Fibre-Shaped Scintillators
- 1 April 2014
- Published by Elsevier in Acta Materialia
- Vol. 67, 232-238
Ce-doped LuAG single-crystal fibers grown from the melt for high-energy physics
- 1 April 2014
- Published by Elsevier in Acta Materialia
- Vol. 67, 232-238
Ce-doped LuAG single-crystal fibers grown from the melt for high-energy physics
- 17 October 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 61 (1) , 456-461
Study of the Angular Distribution of Scintillation Photons
This paper presents a characterization method to experimentally determine the angular distribution of scintillation light. By exciting LYSO crystals with a radioactive source, we measured the light angular profiles obtained with samples of different geometries in different conditions of wrapping. We also measured the angular distribution of light emitting in glue and compared it with the one emitting in air. Angular distribution of light output of photonic crystals is also provided. Consistency of the measurements is verified with conventional light output measurements.
- 17 October 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 61 (1) , 456-461
Study of the Angular Distribution of Scintillation Photons
This paper presents a characterization method to experimentally determine the angular distribution of scintillation light. By exciting LYSO crystals with a radioactive source, we measured the light angular profiles obtained with samples of different geometries in different conditions of wrapping. We also measured the angular distribution of light emitting in glue and compared it with the one emitting in air. Angular distribution of light output of photonic crystals is also provided. Consistency of the measurements is verified with conventional light output measurements.
- 17 October 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 61 (1) , 472-478
Response of Inorganic Scintillators to Neutrons of 3 and 15 MeV Energy
In the perspective of the development of future high energy physics experiments, homogeneous calorimeters based on inorganic scintillators can be considered for the detection of hadrons (e.g., calorimeter based on dual-readout technique). Although of high importance in the high energy physics framework as well as for homeland security applications, the response of these inorganic scintillators to neutrons has been only scarcely investigated. This paper presents results obtained using five common scintillating crystals (of size around 2×2×2 cm 3 ), namely lead tungstate (PbWO 4 ), bismuth germanate (BGO), cerium fluoride (CeF ), Ce-doped lutetium-yttrium orthosilicate (LYSO:Ce) and lutetium aluminum garnet (LuAG:Ce) in a pulsed flux of almost mono-energetic (~3 MeV and ~15 MeV) neutrons provided by the Van de Graff accelerator SAMES of CEA Valduc. Energy spectra have been recorded, calibrated and compared with Geant4 simulations computed with different physics models. The neutron detection efficiency for these crystals has been estimated and compared with simulation.
- 17 October 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 61 (1) , 472-478
Response of Inorganic Scintillators to Neutrons of 3 and 15 MeV Energy
In the perspective of the development of future high energy physics experiments, homogeneous calorimeters based on inorganic scintillators can be considered for the detection of hadrons (e.g., calorimeter based on dual-readout technique). Although of high importance in the high energy physics framework as well as for homeland security applications, the response of these inorganic scintillators to neutrons has been only scarcely investigated. This paper presents results obtained using five common scintillating crystals (of size around 2×2×2 cm 3 ), namely lead tungstate (PbWO 4 ), bismuth germanate (BGO), cerium fluoride (CeF ), Ce-doped lutetium-yttrium orthosilicate (LYSO:Ce) and lutetium aluminum garnet (LuAG:Ce) in a pulsed flux of almost mono-energetic (~3 MeV and ~15 MeV) neutrons provided by the Van de Graff accelerator SAMES of CEA Valduc. Energy spectra have been recorded, calibrated and compared with Geant4 simulations computed with different physics models. The neutron detection efficiency for these crystals has been estimated and compared with simulation.