Imaging Performance for Two Row–Column Arrays
- 1 May 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 66 (7) , 1209-1221
Abstract
This study evaluates the volumetric imaging performance of two prototyped 62+62 row–column-addressed (RCA) 2-D array transducer probes using three Synthetic Aperture Imaging (SAI) emission sequences and two different beamsformers. The probes are fabricated using capacitive micromachined ultrasonic transducer (CMUT), and piezoelectric transducer (PZT) technology. Both have integrated apodization to reduce ghost echoes and are designed with similar acoustical features i.e., 3MHz center frequency, l/2-pitch, and 24.8×24.8mm2 active footprint. Raw RF data are obtained using an experimental research ultrasound scanner, SARUS. The SAI sequences are designed for imaging down to 14 cm at a volume rate of 88 Hz. Two beamforming methods: Spatial matched filtering and rowcolumn adapted delay-and-sum are used for beamforming the RF data. The imaging quality is investigated through simulations and phantom measurements. Both probes on average have similar lateral full-width at half-maximum (FWHM) values, but the PZT probe has 20% smaller cystic resolution values and 70% larger contrast-to-noise ratio compared to the CMUT probe. The CMUT probe can penetrate down to 15 cm, and the PZT probe down to 30 cm. The CMUT probe has 17% smaller axial FWHM values. The matched filter focusing shows and improved B-mode image for measurements on a cyst phantom with an improved speckle pattern and better visualization of deeper lying cysts. The results of this study demonstrate the potentials of RCA 2-D arrays against fully addressed 2-D arrays, which are low channel count (e.g. 124 instead of 3,844), low acoustic intensity (MI ≤0.88 and Ispta ≤5.5mW/cm2), and high penetration depth (down to 30 cm), which makes 3-D imaging at high volume rates possible with equipment in the price range of conventional 2-D imaging.Keywords
Funding Information
- Højteknologifonden (82-2014-4)
- BK Ultrasound ApS, Herlev, Denmark
This publication has 41 references indexed in Scilit:
- 3-D imaging using row-column-addressed arrays with integrated apodization - part i: apodization design and line element beamformingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2015
- 3-D imaging using row–column-addressed arrays with integrated apodization— part ii: transducer fabrication and experimental resultsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2015
- Feasibility of modulation-encoded TOBE CMUTS for real-time 3-D imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2015
- Top orthogonal to bottom electrode (TOBE) 2-D CMUT arrays for 3-D photoacoustic imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2014
- 2-D tissue motion compensation of synthetic transmit aperture imagesIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2014
- Top-orthogonal-to-bottom-electrode (TOBE) CMUT arrays for 3-D ultrasound imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2014
- Beamforming of sound from two-dimensional arrays using spatial matched filtersThe Journal of the Acoustical Society of America, 2013
- SARUS: A synthetic aperture real-time ultrasound systemIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2013
- Synthetic aperture ultrasound imagingUltrasonics, 2006
- Efficient array beam forming by spatial filtering for ultrasound B-mode imagingThe Journal of the Acoustical Society of America, 2006