The role of polymer surface degradation and barium sulphate release in the pathogenesis of catheter-related infection
Open Access
- 23 November 2009
- journal article
- research article
- Published by Oxford University Press (OUP) in Nephrology Dialysis Transplantation
- Vol. 25 (4) , 1207-1213
Abstract
Background. Susceptibility to infection and thrombosis of intravascular catheters is increased by surface irregularities, which might be prevented by coating. Methods. BaSO4 release from conventional haemodialysis catheters (CC) and modified catheters (MC) which had been coated with a surface-modifying additive (SMA) was assessed in vivo and in vitro. For the in vivo part, patients were randomized to receive a temporary CC or MC, with crossover after 1 week. After retrieval, catheters were examined using scanning electron microscopy to assess surface integrity, and an in vitro model of catheter exposure to the bloodstream was used to evaluate surface morphology and susceptibility to bacterial adhesion and proliferation. Results. BaSO4 moieties covered 14.7 ± 3.7% of the surface of unused CC. After in vivo use in 16 patients, 62.7 ± 32.9 × 103 holes/mm2 were detected, indicating BaSO4 detachment from 3.3 ± 1.7% of the catheter surface. No defects were observed in unused CC and in MC, whether used or unused. After incubation of four catheters (two of each type) with Staphylococcusepidermidis, the two degraded CC showed an immediate and strong bacterial growth as indicated by an increase in medium impedance of 0.512%/10 min compared to −0.021%/10 min in MC (P < 0.001). Conclusions. Short-term exposure of CC to the bloodstream causes BaSO4 particle release, resulting in surface irregularities predisposing to bacterial proliferation. BaSO4 release can be prevented by SMA coating.Keywords
This publication has 20 references indexed in Scilit:
- Infections Associated with Medical DevicesDrugs, 2005
- Biofilms: Survival Mechanisms of Clinically Relevant MicroorganismsClinical Microbiology Reviews, 2002
- Effect of radiographic contrast agents on leukocyte metabolic responsePediatric Radiology, 2000
- The hemodialysis catheter conundrum: Hate living with them, but can’t live without themKidney International, 1999
- Transient adhesion of platelets in pump-oxygenator systems: influence of SMA and nitric oxide treatmentsJournal of Biomaterials Science, Polymer Edition, 1999
- Effect of microstructure of poly(propylene‐oxide)‐segmented polyamides on platelet adhesionJournal of Biomedical Materials Research, 1986
- Hydrophilic‐hydrophobic microdomain surfaces having an ability to suppress platelet aggregation and their in vitro antithrombogenicityJournal of Biomedical Materials Research, 1986
- Roughness and thrombogenicity of the outer surfaces of intravascular cathetersJournal of Biomedical Materials Research, 1985
- Thrombogenic properties of arterial catheters: A scanning electron microscopic examination of the surface structureCatheterization and Cardiovascular Diagnosis, 1977
- Scanning electron microscopy of surface irregularities and thrombogenesis of polyurethane and polyethylene coronary catheters.Circulation, 1976