Subject: Re-submission of Manuscript (EA26-2379)CuNWs-PEDOT:PSS Nanocomposite-Based Molecularly Imprinted Electrochemical Platform for the Trace-Level Detection of Famciclovir in Serum and Tablet Dosage Forms
Preprint
- 31 July 2026
- preprint
- Published by Elsevier in SSRN Electronic Journal
Abstract
This study describes the development of a novel, highly sensitive molecularly imprinted polymer (MIP) based electrochemical sensor for the rapid and selective detection of Famciclovir (FAM), an antiviral prodrug. The sensor fabrication involved modifying a glassy carbon electrode (GCE) with copper nanowires (CuNWs) and poly(3,4-ethylenedioxythiophene) (PEDOT:PSS) via physical adsorption, followed by the electropolymerization of o-phenylenediamine (o-PD) in the presence of FAM using cyclic voltammetry. The surface characterization of the CuNWs-PEDOT:PSS@P(o-PD)-FAM/GCE sensor was conducted using atomic force microscopy (AFM), fourier transform infrared spectrometry with attenuated total reflectance (FTIR-ATR), and field emission scanning electron microscopy (FESEM). Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were employed for electrochemical characterization with ferri/ferrocyanide ([Fe(CN)6]3−/4−) redox probe. Analytical evaluations using Differential Pulse Voltammetry (DPV) revealed exceptional sensitivity, featuring a linear range of 1.0×10⁻¹⁴ – 1.0×10⁻¹³ M and an ultra-low detection limit (LOD) of 2.44 × 10⁻¹⁵ M. The sensor's practical utility was validated in pharmaceutical formulations and human serum, yielding high recovery rates of 99.86% and 102.4% (average), respectively. Selectivity studies against common interferents confirmed the robust molecular recognition capability of the developed MIP platform for trace-level FAM analysis in complex matrices.Keywords
This publication has 37 references indexed in Scilit:
- A novel electrochemical sensor based on MIP technology for sensitive determination of cinacalcet hydrochloride in tablet dosage form and serum samplesMicrochimica Acta, 2025
- Investigation of electrochemical behaviour and determination of Riociguat with bare GCE and molecularly imprinted polymer-based electrochemical sensorElectrochimica Acta, 2024
- An electrochemical molecularly imprinted sensor based on CuBi2O4/rGO@MoS2 nanocomposite and its utilization for highly selective and sensitive for linagliptin assayChemosphere, 2022
- Treatment and Prevention of Pandemic H1N1 InfluenzaAnnals of Global Health, 2016
- Synthesis and application of a molecularly imprinted polymer for the voltammetric determination of famciclovirBiosensors and Bioelectronics, 2015
- An Electrochemical Sensor for Reducing Sugars Based on a Glassy Carbon Electrode Modified with Electropolymerized Molecularly Imprinted Poly‐o‐phenylenediamine FilmElectroanalysis, 2014
- Thin-film electrochemical sensor for diphenylamine detection using molecularly imprinted polymersAnalytica Chimica Acta, 2014
- A one-pot ‘green’ synthesis of Pd-decorated PEDOT nanospheres for nonenzymatic hydrogen peroxide sensingBiosensors and Bioelectronics, 2013
- Molecularly imprinted polyaniline-polyvinyl sulphonic acid composite based sensor for para-nitrophenol detectionAnalytica Chimica Acta, 2013
- Detection of nicotine based on molecularly imprinted TiO2-modified electrodesAnalytica Chimica Acta, 2009