Cigdem Kanbes-Dindar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Cigdem Kanbes-Dindar has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Bengi Uslu
Ankara University
8 shared publications - Burcin Bozal-Palabiyik
Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, 06560, Ankara, Turkey
2 shared publications - Melike Akan
ANKARA HACI BAYRAM VELİ ÜNİVERSİTESİ, POLATLI FEN-EDEBİYAT FAKÜLTESİ
2 shared publications - Nazife Aslan
Ankara Haci Bayram Veli Universitesi
2 shared publications Ali Onur Asap
UNAM─National Nanotechnology Research Center
1 shared publication- Arzu Karayel
Department of Physics, Faculty of Arts and Sciences Hitit University Corum Turkey
1 shared publication
Latest Publications
- Open Access
- 31 July 2026
- Published by Elsevier in SSRN Electronic Journal
Subject: Re-submission of Manuscript (EA26-2379)CuNWs-PEDOT:PSS Nanocomposite-Based Molecularly Imprinted Electrochemical Platform for the Trace-Level Detection of Famciclovir in Serum and Tablet Dosage Forms
This study describes the development of a novel, highly sensitive molecularly imprinted polymer (MIP) based electrochemical sensor for the rapid and selective detection of Famciclovir (FAM), an antiviral prodrug. The sensor fabrication involved modifying a glassy carbon electrode (GCE) with copper nanowires (CuNWs) and poly(3,4-ethylenedioxythiophene) (PEDOT:PSS) via physical adsorption, followed by the electropolymerization of o-phenylenediamine (o-PD) in the presence of FAM using cyclic voltammetry. The surface characterization of the CuNWs-PEDOT:PSS@P(o-PD)-FAM/GCE sensor was conducted using atomic force microscopy (AFM), fourier transform infrared spectrometry with attenuated total reflectance (FTIR-ATR), and field emission scanning electron microscopy (FESEM). Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were employed for electrochemical characterization with ferri/ferrocyanide ([Fe(CN)6]3−/4−) redox probe. Analytical evaluations using Differential Pulse Voltammetry (DPV) revealed exceptional sensitivity, featuring a linear range of 1.0×10⁻¹⁴ – 1.0×10⁻¹³ M and an ultra-low detection limit (LOD) of 2.44 × 10⁻¹⁵ M. The sensor's practical utility was validated in pharmaceutical formulations and human serum, yielding high recovery rates of 99.86% and 102.4% (average), respectively. Selectivity studies against common interferents confirmed the robust molecular recognition capability of the developed MIP platform for trace-level FAM analysis in complex matrices.
- 31 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSubject: Re-submission of Manuscript (EA26-2379)CuNWs-PEDOT:PSS Nanocomposite-Based Molecularly Imprinted Electrochemical Platform for the Trace-Level Detection of Famciclovir in Serum and Tablet Dosage Forms
This study describes the development of a novel, highly sensitive molecularly imprinted polymer (MIP) based electrochemical sensor for the rapid and selective detection of Famciclovir (FAM), an antiviral prodrug. The sensor fabrication involved modifying a glassy carbon electrode (GCE) with copper nanowires (CuNWs) and poly(3,4-ethylenedioxythiophene) (PEDOT:PSS) via physical adsorption, followed by the electropolymerization of o-phenylenediamine (o-PD) in the presence of FAM using cyclic voltammetry. The surface characterization of the CuNWs-PEDOT:PSS@P(o-PD)-FAM/GCE sensor was conducted using atomic force microscopy (AFM), fourier transform infrared spectrometry with attenuated total reflectance (FTIR-ATR), and field emission scanning electron microscopy (FESEM). Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were employed for electrochemical characterization with ferri/ferrocyanide ([Fe(CN)6]3−/4−) redox probe. Analytical evaluations using Differential Pulse Voltammetry (DPV) revealed exceptional sensitivity, featuring a linear range of 1.0×10⁻¹⁴ – 1.0×10⁻¹³ M and an ultra-low detection limit (LOD) of 2.44 × 10⁻¹⁵ M. The sensor's practical utility was validated in pharmaceutical formulations and human serum, yielding high recovery rates of 99.86% and 102.4% (average), respectively. Selectivity studies against common interferents confirmed the robust molecular recognition capability of the developed MIP platform for trace-level FAM analysis in complex matrices.
- Open Access
- 31 March 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (14) , 21657-21670
Multianalytical and Theoretical Tendency for the Clarification of the Binding of Lansoprazole and Albumin Protein
Understanding the interaction between pharmaceutical agents and serum albumin is critical for assessing drug bioavailability, distribution, and pharmacokinetics. In this study, the binding mechanism of lansoprazole (LAN) to bovine serum albumin (BSA) was systematically investigated using spectroscopic, electrochemical, and computational approaches. Fluorescence quenching experiments showed that the interaction follows a dynamic quenching mechanism and a moderate affinity, revealing a binding constant of 1.25, 2.76, and 5.24 × 104 M-1 for 287, 298, and 307 K, respectively. Thermodynamic analysis revealed that the binding process is predominantly driven by hydrophobic interactions, as supported by positive enthalpy (ΔH) and entropy (ΔS) values. UV-vis absorption spectroscopy confirmed structural changes in BSA upon LAN binding, while three-dimensional fluorescence spectroscopy showed changes in the microenvironment of tryptophan and tyrosine residues. Electrochemical studies also supported the formation of a stable, nonelectroactive LAN-BSA complex, leading to decreased peak currents. Molecular docking and molecular dynamics simulations provided atomic-level information, showing that LAN preferentially binds to the I site of BSA, stabilized by hydrogen bonding and hydrophobic interactions. Circular dichroism spectral results indicated a secondary structural change in HSA upon LAN binding. The findings of this study contribute to a better understanding of the pharmacokinetic behavior of LAN, providing valuable information about its therapeutic efficacy and potential drug-protein interactions.
- 31 March 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (14) , 21657-21670
Open AccessMultianalytical and Theoretical Tendency for the Clarification of the Binding of Lansoprazole and Albumin Protein
Understanding the interaction between pharmaceutical agents and serum albumin is critical for assessing drug bioavailability, distribution, and pharmacokinetics. In this study, the binding mechanism of lansoprazole (LAN) to bovine serum albumin (BSA) was systematically investigated using spectroscopic, electrochemical, and computational approaches. Fluorescence quenching experiments showed that the interaction follows a dynamic quenching mechanism and a moderate affinity, revealing a binding constant of 1.25, 2.76, and 5.24 × 104 M-1 for 287, 298, and 307 K, respectively. Thermodynamic analysis revealed that the binding process is predominantly driven by hydrophobic interactions, as supported by positive enthalpy (ΔH) and entropy (ΔS) values. UV-vis absorption spectroscopy confirmed structural changes in BSA upon LAN binding, while three-dimensional fluorescence spectroscopy showed changes in the microenvironment of tryptophan and tyrosine residues. Electrochemical studies also supported the formation of a stable, nonelectroactive LAN-BSA complex, leading to decreased peak currents. Molecular docking and molecular dynamics simulations provided atomic-level information, showing that LAN preferentially binds to the I site of BSA, stabilized by hydrogen bonding and hydrophobic interactions. Circular dichroism spectral results indicated a secondary structural change in HSA upon LAN binding. The findings of this study contribute to a better understanding of the pharmacokinetic behavior of LAN, providing valuable information about its therapeutic efficacy and potential drug-protein interactions.
- Open Access
- 8 November 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (45) , 53897-53906
Molecularly Imprinted Polymer-Enhanced Electrochemical Sensor for Sensitive and Selective Captan Detection in Fruit Sample
In this study, a molecularly imprinted polymer (MIP) was designed for the selective, rapid, and sensitive electrochemical detection of Captan, a pesticide. The sensor was fabricated by electropolymerizing o-phenylenediamine (o-PD) onto a glassy carbon electrode (GCE) in the presence of Captan as the template molecule, using cyclic voltammetry (CV). Differential pulse voltammetry (DPV) was used to facilitate template removal and reattachment, optimize experimental conditions, and evaluate sensor performance. A ferrocyanide/ferricyanide redox indicator monitored each stage of the experiment via DPV. The MIP@o-PD/GCE sensor demonstrated a linear response to Captan within the concentration range of 1 × 10-14 to 9 × 10-14 M under optimal conditions, making it suitable for quantifying Captan in apples. To verify its applicability, the sensor was successfully tested on apple samples. Additionally, potential interference was evaluated by comparing its response to KCl, CaCl2, MgCl2, Na2SO4, Ascorbic acid, glucose, and KNO3. The imprinting factor was used to demonstrate the selectivity of the proposed sensors using structurally similar compounds to Captan.
- 8 November 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (45) , 53897-53906
Open AccessMolecularly Imprinted Polymer-Enhanced Electrochemical Sensor for Sensitive and Selective Captan Detection in Fruit Sample
In this study, a molecularly imprinted polymer (MIP) was designed for the selective, rapid, and sensitive electrochemical detection of Captan, a pesticide. The sensor was fabricated by electropolymerizing o-phenylenediamine (o-PD) onto a glassy carbon electrode (GCE) in the presence of Captan as the template molecule, using cyclic voltammetry (CV). Differential pulse voltammetry (DPV) was used to facilitate template removal and reattachment, optimize experimental conditions, and evaluate sensor performance. A ferrocyanide/ferricyanide redox indicator monitored each stage of the experiment via DPV. The MIP@o-PD/GCE sensor demonstrated a linear response to Captan within the concentration range of 1 × 10-14 to 9 × 10-14 M under optimal conditions, making it suitable for quantifying Captan in apples. To verify its applicability, the sensor was successfully tested on apple samples. Additionally, potential interference was evaluated by comparing its response to KCl, CaCl2, MgCl2, Na2SO4, Ascorbic acid, glucose, and KNO3. The imprinting factor was used to demonstrate the selectivity of the proposed sensors using structurally similar compounds to Captan.
- 16 July 2024
- Published by Elsevier in Analytical Biochemistry
- Vol. 694, 115622
Spectroscopic, electrochemical, and molecular docking studies of the interaction between the antihistamine drug desloratadine and dsDNA
- 16 July 2024
- Published by Elsevier in Analytical Biochemistry
- Vol. 694, 115622
Spectroscopic, electrochemical, and molecular docking studies of the interaction between the antihistamine drug desloratadine and dsDNA
- 5 February 2024
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 48 (8) , 3729-3740
Green electrochemical nanosensor platform design for mexiletine detection based on Citrus reticulata peel-mediated iron nanoparticles and quantum dots and investigation of the adsorption mechanism by the DFT-D3 method
Green nanoparticle production is widespread, dependable, affordable, and ecologically beneficial. Citrus reticulata shells were used to synthesize FeNPs and CQDs. Using a simple procedure, the nanosensor platform was formed by modifying the synthesized FeNPs and CQDs onto the surface of a glassy carbon electrode (GCE). Scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR) were all used to evaluate the nanomaterials in detail. Also, differential pulse voltammetry (DPV) and chronocoulometry methods were used to investigate the modified electrodes. AdSDPV was used to analyze mexiletine using the modified electrode of CQDs/FeNPs/GCE. Green nanomaterials in electrochemical nanosensors improve electron transport and electrocatalytic activity towards mexiletine oxidation. The CQDs/FeNPs/GCE increased the electro-oxidation peak current of mexiletine by 18 times compared to the bare GCE. Both standard and serum samples respond linearly to mexiletine at concentrations between 1.0 × 10−7 M and 1.0 × 10−6 M under optimum circumstances. 8.19 × 10−8 and 6.14 × 10−8 M were the detection limits. The sensor identified mexiletine in serum with 99% accuracy. It exhibits excellent repeatability and long-term stability. Furthermore, the mechanism of physical adsorption of mexiletine onto the Fe2O3 NP@CQD electrode surface was studied using Dispersion-Corrected Density Functional Theory (DFT-D3). Negative adsorption energy with the value of −5.51 eV indicates stable adsorption of mexiletine on the electrode surface.
- 5 February 2024
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 48 (8) , 3729-3740
Green electrochemical nanosensor platform design for mexiletine detection based on Citrus reticulata peel-mediated iron nanoparticles and quantum dots and investigation of the adsorption mechanism by the DFT-D3 method
Green nanoparticle production is widespread, dependable, affordable, and ecologically beneficial. Citrus reticulata shells were used to synthesize FeNPs and CQDs. Using a simple procedure, the nanosensor platform was formed by modifying the synthesized FeNPs and CQDs onto the surface of a glassy carbon electrode (GCE). Scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR) were all used to evaluate the nanomaterials in detail. Also, differential pulse voltammetry (DPV) and chronocoulometry methods were used to investigate the modified electrodes. AdSDPV was used to analyze mexiletine using the modified electrode of CQDs/FeNPs/GCE. Green nanomaterials in electrochemical nanosensors improve electron transport and electrocatalytic activity towards mexiletine oxidation. The CQDs/FeNPs/GCE increased the electro-oxidation peak current of mexiletine by 18 times compared to the bare GCE. Both standard and serum samples respond linearly to mexiletine at concentrations between 1.0 × 10−7 M and 1.0 × 10−6 M under optimum circumstances. 8.19 × 10−8 and 6.14 × 10−8 M were the detection limits. The sensor identified mexiletine in serum with 99% accuracy. It exhibits excellent repeatability and long-term stability. Furthermore, the mechanism of physical adsorption of mexiletine onto the Fe2O3 NP@CQD electrode surface was studied using Dispersion-Corrected Density Functional Theory (DFT-D3). Negative adsorption energy with the value of −5.51 eV indicates stable adsorption of mexiletine on the electrode surface.
- Open Access
- 1 January 2024
- Published by Ankara Universitesi Eczacilik Fakultesi Dergisi in Ankara Universitesi Eczacilik Fakultesi Dergisi
- Vol. 48 (3) , 30
DETERMINATION OF ANTIVIRAL-DRUG FAVIPIRAVIR FROM BIOLOGICAL SAMPLES BY USING MOLECULAR IMPRINTED POLYMER-BASED ELECTROCHEMICAL SENSOR
Objective: The molecularly imprinted polymer (MIP) technique was applied in this study for selective, fast, and sensitive electrochemical determination of antiviral drug favipiravir (FAVI). Material and Method: By electropolymerizing the functional monomer o-phenylenediamine (o-PD) on a glassy carbon electrode (GCE) in the presence of a template molecule FAVI, the new MIP-based sensor (MIP@o-PD/GCE) was constructed using cyclic voltammetry (CV). For the removal and rebinding procedures, as well as the optimization of conditions and performance measurement of MIP@o-PD/GCE, differential pulse voltammetry (DPV) was used. The ferrocyanide/ferricyanide redox marker was used to monitor each step of the experimental procedure using DPV. Result and Discussion: MIP@o-PD/GCE has a linear response to FAVI in the range from 10 pM to 90 pM under optimal experimental conditions for human serum samples. The detection limit of MIP@o-PD/GCE was obtained to be 1.80 pM, whereas the quantification limit was found to be 6.23 pM. The designed sensor was successfully applied to a synthetic human serum sample to verify its applicability and validity. Electrochemical sensor selectivity was evaluated by comparing the binding of paracetamol and tenofovir, which are similar to favipiravir, and also oseltamivir and famciclovir, which are other drugs used in the treatment of COVID-19.
- 1 January 2024
- Published by Ankara Universitesi Eczacilik Fakultesi Dergisi in Ankara Universitesi Eczacilik Fakultesi Dergisi
- Vol. 48 (3) , 30
Open AccessDETERMINATION OF ANTIVIRAL-DRUG FAVIPIRAVIR FROM BIOLOGICAL SAMPLES BY USING MOLECULAR IMPRINTED POLYMER-BASED ELECTROCHEMICAL SENSOR
Objective: The molecularly imprinted polymer (MIP) technique was applied in this study for selective, fast, and sensitive electrochemical determination of antiviral drug favipiravir (FAVI). Material and Method: By electropolymerizing the functional monomer o-phenylenediamine (o-PD) on a glassy carbon electrode (GCE) in the presence of a template molecule FAVI, the new MIP-based sensor (MIP@o-PD/GCE) was constructed using cyclic voltammetry (CV). For the removal and rebinding procedures, as well as the optimization of conditions and performance measurement of MIP@o-PD/GCE, differential pulse voltammetry (DPV) was used. The ferrocyanide/ferricyanide redox marker was used to monitor each step of the experimental procedure using DPV. Result and Discussion: MIP@o-PD/GCE has a linear response to FAVI in the range from 10 pM to 90 pM under optimal experimental conditions for human serum samples. The detection limit of MIP@o-PD/GCE was obtained to be 1.80 pM, whereas the quantification limit was found to be 6.23 pM. The designed sensor was successfully applied to a synthetic human serum sample to verify its applicability and validity. Electrochemical sensor selectivity was evaluated by comparing the binding of paracetamol and tenofovir, which are similar to favipiravir, and also oseltamivir and famciclovir, which are other drugs used in the treatment of COVID-19.
- Open Access
- 1 January 2024
- Published by Ankara Universitesi Eczacilik Fakultesi Dergisi in Ankara Universitesi Eczacilik Fakultesi Dergisi
- Vol. 48 (3) , 27
DETERMINATION OF ANTI-CANCER DRUG PALBOCICLIB FROM HUMAN BIOLOGICAL FLUIDS BY USING DIFFERENTIAL PULSE VOLTAMMETRIC METHOD AT BORON DOPED DIAMOND ELECTRODE
Objective: A very efficient and sensitive electrochemical technique utilizing differential pulse voltammetry (DPV) at a boron-doped diamond electrode (BDDE) was devised to measure Palbociclib in this study. Material and Method: All experiments employed typical three-electrode cell of 10 ml capacity in conjunction with boron-doped diamond electrode, a platinum wire counter electrode, and an Ag/AgCl reference electrode. During electrochemical measurements, DPV and cyclic voltammetry (CV) methods was utilized at BDDE. Result and Discussion: Based on experimental findings from electrochemical characterization investigations, it was determined that oxidation behavior of Palbociclib in BDDE is irreversible and regulated by diffusion. Anodic peak current exhibited a linear relationship within concentration range of 0.01–1 µM, 0.02–0.8 µM, and 0.02–0.8 µM in pH 2.0 phosphate buffer solution (PBS) for reference substance solution, human serum, and urine samples, respectively. Limits of detection were found as 2.28 nM, 2.93 nM, and 1.31 nM for standard drug solution, human serum and urine samples, respectively. In order to validate the developed method, its repeatability, reproducibility, selectivity, precision and accuracy in all environments were investigated and calculated. This method was successfully applied for the analysis of Palbociclib in human serum and urine samples .
- 1 January 2024
- Published by Ankara Universitesi Eczacilik Fakultesi Dergisi in Ankara Universitesi Eczacilik Fakultesi Dergisi
- Vol. 48 (3) , 27
Open AccessDETERMINATION OF ANTI-CANCER DRUG PALBOCICLIB FROM HUMAN BIOLOGICAL FLUIDS BY USING DIFFERENTIAL PULSE VOLTAMMETRIC METHOD AT BORON DOPED DIAMOND ELECTRODE
Objective: A very efficient and sensitive electrochemical technique utilizing differential pulse voltammetry (DPV) at a boron-doped diamond electrode (BDDE) was devised to measure Palbociclib in this study. Material and Method: All experiments employed typical three-electrode cell of 10 ml capacity in conjunction with boron-doped diamond electrode, a platinum wire counter electrode, and an Ag/AgCl reference electrode. During electrochemical measurements, DPV and cyclic voltammetry (CV) methods was utilized at BDDE. Result and Discussion: Based on experimental findings from electrochemical characterization investigations, it was determined that oxidation behavior of Palbociclib in BDDE is irreversible and regulated by diffusion. Anodic peak current exhibited a linear relationship within concentration range of 0.01–1 µM, 0.02–0.8 µM, and 0.02–0.8 µM in pH 2.0 phosphate buffer solution (PBS) for reference substance solution, human serum, and urine samples, respectively. Limits of detection were found as 2.28 nM, 2.93 nM, and 1.31 nM for standard drug solution, human serum and urine samples, respectively. In order to validate the developed method, its repeatability, reproducibility, selectivity, precision and accuracy in all environments were investigated and calculated. This method was successfully applied for the analysis of Palbociclib in human serum and urine samples .
- 1 December 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (12) , 127510
Voltammetric Analysis of Thiram with Bimetallic Nanosensor and Investigation of Adsorption Mechanism by DFT-D3 Method
In this study, to detect thiram electrochemically, a simple nanosensor based on a glassy carbon electrode (GCE) modified with green-synthesized Ag and Au nanoparticles was designed. AuNPs@AgNPs/GCE nanosensor gave considerably greater signal for 5 ppm thiram in pH 3.0 phosphate buffer solution using adsorptive stripping differential pulse voltammetry compared to bare GCE. Under ideal conditions, the nanosensor produced a linear concentration calibration curve extending from 0.2 to 1.4 ppm for thiram, with limits of detection and quantification of 0.033 ppm and 0.100 ppm, respectively. The developed electrochemical bimetallic nanosensor demonstrated high sensitivity and stability, showing that it is a novel and promising platform for thiram determination. Furthermore, the nanosensor was used to assess thiram in human serum and recovery was obtained as 103.6%. DFT-D3 results showed that covalent modification of GCE with AuNPs/AgNPs occurs with the electron transfer between the electrode surface and thiram by bonding sulfur atoms of thiram to AgNPs and AuNPs. Both experimental and theoretical analyses showed that the modification with Ag and Au, GCE appeared to be a key property to improve the electronic activity at the surface and increase the charge transfer that facilitates the adsorption of the selected guest.
- 1 December 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (12) , 127510
Voltammetric Analysis of Thiram with Bimetallic Nanosensor and Investigation of Adsorption Mechanism by DFT-D3 Method
In this study, to detect thiram electrochemically, a simple nanosensor based on a glassy carbon electrode (GCE) modified with green-synthesized Ag and Au nanoparticles was designed. AuNPs@AgNPs/GCE nanosensor gave considerably greater signal for 5 ppm thiram in pH 3.0 phosphate buffer solution using adsorptive stripping differential pulse voltammetry compared to bare GCE. Under ideal conditions, the nanosensor produced a linear concentration calibration curve extending from 0.2 to 1.4 ppm for thiram, with limits of detection and quantification of 0.033 ppm and 0.100 ppm, respectively. The developed electrochemical bimetallic nanosensor demonstrated high sensitivity and stability, showing that it is a novel and promising platform for thiram determination. Furthermore, the nanosensor was used to assess thiram in human serum and recovery was obtained as 103.6%. DFT-D3 results showed that covalent modification of GCE with AuNPs/AgNPs occurs with the electron transfer between the electrode surface and thiram by bonding sulfur atoms of thiram to AgNPs and AuNPs. Both experimental and theoretical analyses showed that the modification with Ag and Au, GCE appeared to be a key property to improve the electronic activity at the surface and increase the charge transfer that facilitates the adsorption of the selected guest.
- 29 June 2022
- Published by Turkish Journal of Analytical Chemistry in Turkish Journal of Analytical Chemistry
- Vol. 4 (1) , 37-43
Electrochemical determination of antiviral drug Famciclovir in human serum samples at boron-doped diamond electrode
The electrochemical oxidation of famciclovir was investigated in pH range 2.0-10.0 using differential pulse voltammetry at boron-doped diamond electrode. The experimental results from pH and scan rate studies showed that the oxidation behavior of famciclovir at boron doped diamond electrode was irreversible and diffusion-controlled. Also, by using differential pulse technique at electrode, the anodic peak current is obtained to be linear over the range of concentration 0.5 µM - 12 µM and 6 µM - 100 µM in pH 4.7 acetate buffer solution (ABS) for standard drug solution and human serum, respectively. Limits of detection were 0.022 µM and 0.42 µM for standard drug solution and human serum, respectively. The repeatability, reproducibility, selectivity, precision and accuracy of developed method in all media were investigated and calculated. This method was successfully applied for the analysis of famciclovir human serum samples.
- 29 June 2022
- Published by Turkish Journal of Analytical Chemistry in Turkish Journal of Analytical Chemistry
- Vol. 4 (1) , 37-43
Electrochemical determination of antiviral drug Famciclovir in human serum samples at boron-doped diamond electrode
The electrochemical oxidation of famciclovir was investigated in pH range 2.0-10.0 using differential pulse voltammetry at boron-doped diamond electrode. The experimental results from pH and scan rate studies showed that the oxidation behavior of famciclovir at boron doped diamond electrode was irreversible and diffusion-controlled. Also, by using differential pulse technique at electrode, the anodic peak current is obtained to be linear over the range of concentration 0.5 µM - 12 µM and 6 µM - 100 µM in pH 4.7 acetate buffer solution (ABS) for standard drug solution and human serum, respectively. Limits of detection were 0.022 µM and 0.42 µM for standard drug solution and human serum, respectively. The repeatability, reproducibility, selectivity, precision and accuracy of developed method in all media were investigated and calculated. This method was successfully applied for the analysis of famciclovir human serum samples.