System overview of the fully implantable destination therapy—ReinHeart-total artificial heart
Open Access
- 18 September 2014
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 47 (1) , 80-86
Abstract
Owing to the lack of suitable allografts, the demand for long-term mechanical circulatory support in patients with biventricular end-stage heart failure is rising. Currently available Total Artificial Heart (TAH) systems consist of pump units with only limited durability, percutaneous tubes and bulky external equipment that limit the quality of life. Therefore we are focusing on the development of a fully implantable, highly durable destination therapy total artificial heart. The ReinHeart-TAH system consists of a passively filling pump unit driven by a low-wear linear drive between two artificial ventricles, an implantable control unit and a compliance chamber. The TAH is powered by a transcutaneous energy transmission system. The flow distribution inside the ventricles was analysed by fluid structure interaction simulation and particle image velocimetry measurements. Along with durability tests, the hydrodynamic performance and flow balance capability were evaluated in a mock circulation loop. Animal trials are ongoing. Based on fluid structure interaction simulation and particle image velocimetry, blood stagnation areas have been significantly reduced. In the mock circulation loop the ReinHeart-TAH generated a cardiac output of 5 l/min at an operating frequency of 120 bpm and an aortic pressure of 120/80 mmHg. The highly effective preload sensitivity of the passively filling ventricles allowed the sensorless integration of the Frank Starling mechanism. The ReinHeart-TAH effectively replaced the native heart's function in animals for up to 2 days. In vitro and in vivo testing showed a safe and effective function of the ReinHeart-TAH system. This has the potential to become an alternative to transplantation. However, before a first-in-man implant, chronic animal trials still have to be completed.Keywords
This publication has 10 references indexed in Scilit:
- Paving the way for destination therapy of end-stage biventricular heart failure: the ReinHeart total artificial heart conceptEuropean Journal of Cardio-Thoracic Surgery, 2014
- Numerical Washout Study of a Pulsatile Total Artificial HeartThe International Journal of Artificial Organs, 2014
- Design and Evaluation of a Hybrid Mock Circulatory Loop for total Artificial Heart TestingThe International Journal of Artificial Organs, 2014
- Simulation of a pulsatile total artificial heart: Development of a partitioned Fluid Structure Interaction modelJournal of Fluids and Structures, 2013
- Fifth INTERMACS annual report: Risk factor analysis from more than 6,000 mechanical circulatory support patientsThe Journal of Heart and Lung Transplantation, 2013
- Image based evaluation of mediastinal constraints for the development of a pulsatile total artificial heartBioMedical Engineering OnLine, 2013
- Continuous-flow devices and percutaneous site infections: Clinical outcomesThe Journal of Heart and Lung Transplantation, 2012
- Experimental study on the wake behind tapered circular cylindersJournal of Fluids and Structures, 2011
- Total artificial heart-implantation technique using the CardioWest or the Thoratec systemMultimedia Manual of Cardio-Thoracic Surgery, 2007
- Durability Testing of a Completely Implantable Electric Total Artificial HeartASAIO Journal, 2005