Improvement of the Spatial Resolution Performance of Miniaturized Streak Tube Using Dual-Focusing
- 24 May 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 52 (5) , 1721-1727
Abstract
In the context of imaging laser radar systems (ILRS), the miniaturized streak tube (MST) serves as a crucial ultrafast diagnostic equipment, enabling the acquisition of high-quality 3-D images. The evaluation of information acquisition largely hinges on the spatial resolution (SR) performance of the MST, making it a significant parameter of interest. To enhance the system’s performance, the imaging system was designed using the dual-electrode electrostatic focusing (DEEF) technique. In this study, the relationship between the focusing electric field and imaging quality was analyzed, while the static and dynamic pattern was constructed by the CST software. To quantify the SR, the Rayleigh criterion (RC) was employed. Furthermore, the feasibility of a larger detection area and higher SR were investigated. The experimental findings revealed that the dual-focusing MST 120-mm-long has better performance, its detection area is $\Phi $ 30 mm, the deflection sensitivity is 15.05 mm/kV, and the static SR is approximately 41.84 lp/mm. Besides, the model of the voltage discrete port and the matching resistance were established, and the dynamic pattern was implemented by introducing the time-varying scanning ramp pulses. Remarkably, when the gradient of the slope pulse was 1.65 kV/ns, the dynamic SR was approximately 23.70 lp/mm, surpassing the performance of single-focusing techniques. The research conclusions not only verify the feasibility of the dual-focusing MST but also provide theoretical support to the design of the MST with high spatial performance. Furthermore, it also provides a reference method for studying the dynamic characteristics of MST by the CST.Keywords
Funding Information
- National Natural Science Foundation of China (11865007)
- Guangxi Natural Science Foundation (2022GXNSFAA035561)
- Director’s Fund of Guangxi Key Laboratory of Automatic Testing Technology and Instruments (YQ22101)
This publication has 17 references indexed in Scilit:
- Development of a large-field streak tube for underwater imaging lidarApplied Optics, 2022
- A New Design of Large-format Streak Tube with Single-lens Focusing SystemMeasurement Science Review, 2021
- Small-size streak tube with high edge spatial resolutionOptik, 2021
- Differential optical-path approach to improving the performance of Multiple-Slit Streak Tube Imaging LiDARMeasurement, 2021
- Ground target extraction using airborne streak tube imaging LiDARJournal of Applied Remote Sensing, 2021
- Design of a large-format high-resolution streak camera with a planar photocathodeNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2020
- Research on streak tube imaging lidar based on photocathode range gating methodOptics Communications, 2019
- A compact large-format streak tube for imaging lidarReview of Scientific Instruments, 2018
- Range accuracy analysis of streak tube imaging lidar systemsOptics Communications, 2016
- Experiments of ocean surface waves and underwater target detection imaging using a slit Streak Tube Imaging LidarOptik, 2014