Yanli Bai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yanli Bai has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Haiying Gao
7 shared publicationsRongbin Yao
School of Information and Communication Guilin University of Electronic Technology 541004 Guilin Guangxi Province P. R. China
7 shared publicationsXun Wang
5 shared publicationsDajian Liu
Guilin Univ Elect Technol, Natl Demonstrat Ctr Expt Educ Mech & Elect Engn T, Guilin 541004, Peoples R China
4 shared publications- Yi Jiang
School of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin, China
4 shared publications - Guochun Huang
School of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin, China
3 shared publications
Latest Publications
- 11 October 2025
- Published by Elsevier in Optics Communications
- Vol. 596
Application of MIMO-UNET with homomorphic filtering technology in pulse-dilation framing camera
- 11 October 2025
- Published by Elsevier in Optics Communications
- Vol. 596
Application of MIMO-UNET with homomorphic filtering technology in pulse-dilation framing camera
- 13 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (6) , 1843-1848
Enhancing Temporal Uniformity in Pulse-Dilation Framing Camera Using Curved-Dilation-Pulse
The pulse-dilation framing camera (PDFC) is a two-dimensional ultrafast diagnostic device with high temporal resolution. In high-energy physics experiments, it can be used to investigate related transient processes and ultrafast dynamics. Nevertheless, the transmission of linear dilation pulse (DP) along photocathode (PC) may lead to temporal resolution non-uniformity in the PDFC, causing variations in the physical information captured at different time points and potentially resulting in distorted observations. To address issue, a curved dilation pulse (CDP) was designed using IGBT, transformer coils, and high-pass filters, and its application in improving temporal uniformity (TU) was investigated. The research findings indicate that the IGBT circuit can generate a CDP with non-linearly rising amplitude and a slope ranging from 0.132 to 3.39 V/ps. Under conditions of -3 kV PC voltage, an initial time width of 10 ps for the electron beam (EB), and a drift distance of 500 mm, when applied to an 80 mm long PC, the average relative error of EB dilation ratio (DR) along PC can be minimized to 0.63% (EBDR: 11.68× to 11.81×). This represents a significant enhancement in TU compared to the 7.20% (3.84× to 4.42×) achieved with the linear ones. Furthermore, when evaluated based on the maximum relative error of EBDR along PC, the CDP achieves 1.11%, compared with the multigroup high-precision time synchronization requirements of multipulse fusion (MPF, 9.14%, 9.52× to 10.39×) and V-shaped pulse superposition (VSPS, 26.15%, 11.28× to 14.23×), the CDP based on IGBT technology only requires a single group of time synchronization to effectively enhance TU. Meanwhile, the CDP can also be applied to one-dimensional streak camera for mitigating dynamic spatio-temporal distortion.
- 13 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (6) , 1843-1848
Enhancing Temporal Uniformity in Pulse-Dilation Framing Camera Using Curved-Dilation-Pulse
The pulse-dilation framing camera (PDFC) is a two-dimensional ultrafast diagnostic device with high temporal resolution. In high-energy physics experiments, it can be used to investigate related transient processes and ultrafast dynamics. Nevertheless, the transmission of linear dilation pulse (DP) along photocathode (PC) may lead to temporal resolution non-uniformity in the PDFC, causing variations in the physical information captured at different time points and potentially resulting in distorted observations. To address issue, a curved dilation pulse (CDP) was designed using IGBT, transformer coils, and high-pass filters, and its application in improving temporal uniformity (TU) was investigated. The research findings indicate that the IGBT circuit can generate a CDP with non-linearly rising amplitude and a slope ranging from 0.132 to 3.39 V/ps. Under conditions of -3 kV PC voltage, an initial time width of 10 ps for the electron beam (EB), and a drift distance of 500 mm, when applied to an 80 mm long PC, the average relative error of EB dilation ratio (DR) along PC can be minimized to 0.63% (EBDR: 11.68× to 11.81×). This represents a significant enhancement in TU compared to the 7.20% (3.84× to 4.42×) achieved with the linear ones. Furthermore, when evaluated based on the maximum relative error of EBDR along PC, the CDP achieves 1.11%, compared with the multigroup high-precision time synchronization requirements of multipulse fusion (MPF, 9.14%, 9.52× to 10.39×) and V-shaped pulse superposition (VSPS, 26.15%, 11.28× to 14.23×), the CDP based on IGBT technology only requires a single group of time synchronization to effectively enhance TU. Meanwhile, the CDP can also be applied to one-dimensional streak camera for mitigating dynamic spatio-temporal distortion.
- 21 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (5) , 1672-1679
Investigation of Dynamic Space Charge Effects in Pulse-Dilation Framing Camera Utilizing Dilation Pulses
The dilation pulse (DP) is a critical factor influencing temporal performance of magnetic focusing pulse-dilation framing camera (PDFC). As DP propagates along photocathode (PC), it not only induces variations in acceleration voltage but also results in different drift times, dilated ratios, and motion radii for electron pulse (EP) at various PC positions. This significantly affects spatiotemporal dispersion (STD) of the dynamic space charge effect (SCE) during EP drift process. To address issue, the drift step recovery diodes (DSRD) are employed to design DP. By establishing connection with the dynamic spatiotemporal characteristics of EP, the impact on dynamic SCE is analyzed. Research results indicate that the DSRD circuit can generate four DPs with peak voltages ranging from -3.508 kV to -1.819 kV, rise times between 236 ps and 288 ps, and average amplitude change rates from 22.36% to 35.0%, as well as slope change rates from 40.07% to 62.80%. When a specific DP is applied to the 50 mm PC, the transient temporal dispersion of SCE during EP drift process is inversely proportional to the electron density and drift velocity. Transient spatial dispersion is significantly influenced by EP’s radius and its ratio to the axial width, decreasing as both factors increase. When the four DPs are individually applied to PC, during EP drift process, the DP with the smallest amplitude change rate and the largest slope change rate reduces the average temporal dispersion along PC from 0.764 ps to 0.590 ps and decreases nonuniformity from 40.69% to 27.73%. The average spatial dispersion is reduced from 21.87 μm to 15.21 μm, and non-uniformity drops from 39.94% to 26.13%. These findings provide basis for analyzing and improving the STD and uniformity of dynamic SCE. Additionally, they offer research insights into integrating high-power pulse technology into ultrafast diagnostic applications.
- 21 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (5) , 1672-1679
Investigation of Dynamic Space Charge Effects in Pulse-Dilation Framing Camera Utilizing Dilation Pulses
The dilation pulse (DP) is a critical factor influencing temporal performance of magnetic focusing pulse-dilation framing camera (PDFC). As DP propagates along photocathode (PC), it not only induces variations in acceleration voltage but also results in different drift times, dilated ratios, and motion radii for electron pulse (EP) at various PC positions. This significantly affects spatiotemporal dispersion (STD) of the dynamic space charge effect (SCE) during EP drift process. To address issue, the drift step recovery diodes (DSRD) are employed to design DP. By establishing connection with the dynamic spatiotemporal characteristics of EP, the impact on dynamic SCE is analyzed. Research results indicate that the DSRD circuit can generate four DPs with peak voltages ranging from -3.508 kV to -1.819 kV, rise times between 236 ps and 288 ps, and average amplitude change rates from 22.36% to 35.0%, as well as slope change rates from 40.07% to 62.80%. When a specific DP is applied to the 50 mm PC, the transient temporal dispersion of SCE during EP drift process is inversely proportional to the electron density and drift velocity. Transient spatial dispersion is significantly influenced by EP’s radius and its ratio to the axial width, decreasing as both factors increase. When the four DPs are individually applied to PC, during EP drift process, the DP with the smallest amplitude change rate and the largest slope change rate reduces the average temporal dispersion along PC from 0.764 ps to 0.590 ps and decreases nonuniformity from 40.69% to 27.73%. The average spatial dispersion is reduced from 21.87 μm to 15.21 μm, and non-uniformity drops from 39.94% to 26.13%. These findings provide basis for analyzing and improving the STD and uniformity of dynamic SCE. Additionally, they offer research insights into integrating high-power pulse technology into ultrafast diagnostic applications.
- 23 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-7
Reduction of Dynamic Spatial Distortion of Miniaturized Streak Tube Using Deflection Compensation Technique
In miniaturized streak tube (MST), the scanning electric field, while deflecting dynamic imaging, inevitably causes dynamic spatial distortion (DSD), declining dynamic spatial resolution (DSR) uniformity and hindering large-area applications. To mitigate these cases, a compensation system has been devised, aiming to reduce DSD and enhance DSR uniformity by the application of the falling edge of V-shaped high-voltage pulse (VHVP). The research results demonstrate that the VHVP, featuring a rising edge slope of 12.68 kV/ns and a falling edge slope of 15.22 kV/ns, which successfully generated by the Marx circuit combined with the LC filter. When the VHVP, in conjunction with the deflection compensation technique (DCT), was implemented in the MST, a notable reduction in DSD was achieved. Specifically, within a Φ30-mm detection area, the DSD ratio has been decreased from 35.61% to 12.09%, accompanied by 5.45% improvement in DSR uniformity at 15-mm off-axis. Furthermore, comparative analysis revealed that compared to a MST with Φ16-mm detection area, which utilized a curved cathode and spherical phosphor screen to achieve 2.31% improvement ratio, the proposed DCT demonstrated significant 17.36% improvement ratio at an 8-mm off-axis point. These findings present a universal and effective approach for the technical enhancement of MST performance.
- 23 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-7
Reduction of Dynamic Spatial Distortion of Miniaturized Streak Tube Using Deflection Compensation Technique
In miniaturized streak tube (MST), the scanning electric field, while deflecting dynamic imaging, inevitably causes dynamic spatial distortion (DSD), declining dynamic spatial resolution (DSR) uniformity and hindering large-area applications. To mitigate these cases, a compensation system has been devised, aiming to reduce DSD and enhance DSR uniformity by the application of the falling edge of V-shaped high-voltage pulse (VHVP). The research results demonstrate that the VHVP, featuring a rising edge slope of 12.68 kV/ns and a falling edge slope of 15.22 kV/ns, which successfully generated by the Marx circuit combined with the LC filter. When the VHVP, in conjunction with the deflection compensation technique (DCT), was implemented in the MST, a notable reduction in DSD was achieved. Specifically, within a Φ30-mm detection area, the DSD ratio has been decreased from 35.61% to 12.09%, accompanied by 5.45% improvement in DSR uniformity at 15-mm off-axis. Furthermore, comparative analysis revealed that compared to a MST with Φ16-mm detection area, which utilized a curved cathode and spherical phosphor screen to achieve 2.31% improvement ratio, the proposed DCT demonstrated significant 17.36% improvement ratio at an 8-mm off-axis point. These findings present a universal and effective approach for the technical enhancement of MST performance.
- Open Access
- 1 September 2024
- Published by China Science Publishing & Media Ltd. in JOURNAL OF SHENZHEN UNIVERSITY SCIENCE AND ENGINEERING
- Vol. 41 (5) , 556-562
Picosecond high voltage pulse of framing camera with synchronous trigger and cascade filter
The pulse-dilation framing camera (PDFC) is a composite of pulse-dilation technique and microchannel plate (MCP) framing camera. Its temporal resolution is a nonlinearly fluctuated relation with picoseconds high voltage pulse (PHVP). The PHVP is generated using the model of synchronous triggering and the cascade structure of the LC high-pass filter, which is combined with the cathode voltage and the drift distance that affect temporal resolution, and is applied to the study of time resolution of PDFC. The research results show that the synchronous triggering Marx circuit can generate high voltage pulse with the full width at half maximum (FWHM) better than 1 ns, and when the LC high-pass filter is increased from the first order to the seventh order, FWHM of the PHVP is reduced from 558 ps to 409 ps, the amplitude is decreased from kV to kV, the slop of the rising edge is nonlinearly fluctuated in the range between 5.03 V/ps and 10.25 V/ps. The temporal resolution of the MCP framing camera is reduced from 206 ps to 149 ps by loading the PHVP on the model of photoelectron multiplication in the channel of the MCP; while the PDFC is loaded by the PHVP, the temporal resolution is nonlinearly fluctuated in the range between 3.8 ps and 39.4 ps by increasing the cathode potential, and drift distance. The temporal resolution of the pulse-dilation framing camera can be optimized by carrying the data statistics and comparisons, when the synchronous trigger Marx circuit is combined with the 3rd order LC high-pass filter circuit.- 1 September 2024
- Published by China Science Publishing & Media Ltd. in JOURNAL OF SHENZHEN UNIVERSITY SCIENCE AND ENGINEERING
- Vol. 41 (5) , 556-562
Open AccessPicosecond high voltage pulse of framing camera with synchronous trigger and cascade filter
The pulse-dilation framing camera (PDFC) is a composite of pulse-dilation technique and microchannel plate (MCP) framing camera. Its temporal resolution is a nonlinearly fluctuated relation with picoseconds high voltage pulse (PHVP). The PHVP is generated using the model of synchronous triggering and the cascade structure of the LC high-pass filter, which is combined with the cathode voltage and the drift distance that affect temporal resolution, and is applied to the study of time resolution of PDFC. The research results show that the synchronous triggering Marx circuit can generate high voltage pulse with the full width at half maximum (FWHM) better than 1 ns, and when the LC high-pass filter is increased from the first order to the seventh order, FWHM of the PHVP is reduced from 558 ps to 409 ps, the amplitude is decreased from kV to kV, the slop of the rising edge is nonlinearly fluctuated in the range between 5.03 V/ps and 10.25 V/ps. The temporal resolution of the MCP framing camera is reduced from 206 ps to 149 ps by loading the PHVP on the model of photoelectron multiplication in the channel of the MCP; while the PDFC is loaded by the PHVP, the temporal resolution is nonlinearly fluctuated in the range between 3.8 ps and 39.4 ps by increasing the cathode potential, and drift distance. The temporal resolution of the pulse-dilation framing camera can be optimized by carrying the data statistics and comparisons, when the synchronous trigger Marx circuit is combined with the 3rd order LC high-pass filter circuit. - 24 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 52 (5) , 1721-1727
Improvement of the Spatial Resolution Performance of Miniaturized Streak Tube Using Dual-Focusing
In the context of imaging laser radar systems (ILRS), the miniaturized streak tube (MST) serves as a crucial ultrafast diagnostic equipment, enabling the acquisition of high-quality 3-D images. The evaluation of information acquisition largely hinges on the spatial resolution (SR) performance of the MST, making it a significant parameter of interest. To enhance the system’s performance, the imaging system was designed using the dual-electrode electrostatic focusing (DEEF) technique. In this study, the relationship between the focusing electric field and imaging quality was analyzed, while the static and dynamic pattern was constructed by the CST software. To quantify the SR, the Rayleigh criterion (RC) was employed. Furthermore, the feasibility of a larger detection area and higher SR were investigated. The experimental findings revealed that the dual-focusing MST 120-mm-long has better performance, its detection area is $\Phi $ 30 mm, the deflection sensitivity is 15.05 mm/kV, and the static SR is approximately 41.84 lp/mm. Besides, the model of the voltage discrete port and the matching resistance were established, and the dynamic pattern was implemented by introducing the time-varying scanning ramp pulses. Remarkably, when the gradient of the slope pulse was 1.65 kV/ns, the dynamic SR was approximately 23.70 lp/mm, surpassing the performance of single-focusing techniques. The research conclusions not only verify the feasibility of the dual-focusing MST but also provide theoretical support to the design of the MST with high spatial performance. Furthermore, it also provides a reference method for studying the dynamic characteristics of MST by the CST.
- 24 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 52 (5) , 1721-1727
Improvement of the Spatial Resolution Performance of Miniaturized Streak Tube Using Dual-Focusing
In the context of imaging laser radar systems (ILRS), the miniaturized streak tube (MST) serves as a crucial ultrafast diagnostic equipment, enabling the acquisition of high-quality 3-D images. The evaluation of information acquisition largely hinges on the spatial resolution (SR) performance of the MST, making it a significant parameter of interest. To enhance the system’s performance, the imaging system was designed using the dual-electrode electrostatic focusing (DEEF) technique. In this study, the relationship between the focusing electric field and imaging quality was analyzed, while the static and dynamic pattern was constructed by the CST software. To quantify the SR, the Rayleigh criterion (RC) was employed. Furthermore, the feasibility of a larger detection area and higher SR were investigated. The experimental findings revealed that the dual-focusing MST 120-mm-long has better performance, its detection area is $\Phi $ 30 mm, the deflection sensitivity is 15.05 mm/kV, and the static SR is approximately 41.84 lp/mm. Besides, the model of the voltage discrete port and the matching resistance were established, and the dynamic pattern was implemented by introducing the time-varying scanning ramp pulses. Remarkably, when the gradient of the slope pulse was 1.65 kV/ns, the dynamic SR was approximately 23.70 lp/mm, surpassing the performance of single-focusing techniques. The research conclusions not only verify the feasibility of the dual-focusing MST but also provide theoretical support to the design of the MST with high spatial performance. Furthermore, it also provides a reference method for studying the dynamic characteristics of MST by the CST.