The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children
- 20 September 2016
- journal article
- research article
- Published by Springer Nature in Child's Nervous System
- Vol. 32 (10) , 1769-1778
Abstract
Purpose The aim of this study was to investigate the relationship between optic nerve sheath diameter (ONSD) measurement and invasively measured intracranial pressure (ICP) in children. Methods ONSD measurement was performed prior to invasive measurement of ICP. The mean binocular ONSD measurement was compared to the ICP reading. Physiological variables including systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), pulse rate, temperature, respiratory rate and end tidal carbon dioxide (ETCO2) level were recorded at the time of ONSD measurement. Diagnostic accuracy analysis was performed at various ICP thresholds and repeatability, intra- and inter-observer variability, correlation between measurements in different imaging planes as well the relationship over the entire patient cohort were examined in part I of this study. Results Data from 174 patients were analysed. Repeatability and intra-observer variability were excellent (α = 0.97–0.99). Testing for inter-observer variability revealed good correlation (r = 0.89, p < 0.001). Imaging in the sagittal plane demonstrated a slightly better correlation with ICP (r = 0.66, p < 0.001). The ONSD measurement with the best diagnostic accuracy for detecting an ICP ≥ 20 mmHg over the entire patient cohort was 5.5 mm, sensitivity 93.2 %, specificity 74 % and odds ratio (OR) of 39.3. Conclusion Transorbital ultrasound measurement of the OSND is a reliable and reproducible technique, demonstrating a good relationship with ICP and high diagnostic accuracy for detecting raised ICP.Keywords
This publication has 47 references indexed in Scilit:
- Reproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imagingBMC Neurology, 2013
- Estimation of optic nerve sheath diameter on an initial brain computed tomography scan can contribute prognostic information in traumatic brain injury patientsCritical Care, 2013
- Ultrasonography of the optic nerve in neurocritically ill patientsActa Anaesthesiologica Scandinavica, 2011
- High Resolution Ultrasound and Magnetic Resonance Imaging of the Optic Nerve and the Optic Nerve Sheath: Anatomic Correlation and Clinical ImportanceUltraschall in der Medizin - European Journal of Ultrasound, 2010
- Optic nerve sonography in the diagnostic evaluation of adult brain injuryCritical Care, 2008
- Correlation of Optic Nerve Sheath Diameter with Direct Measurement of Intracranial PressureAcademic Emergency Medicine, 2008
- Ocular sonography in patients with raised intracranial pressure: the papilloedema revisitedCritical Care, 2008
- DiscussionEuropean Journal of Ultrasound, 1998
- Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertensionPediatric Radiology, 1996
- PATHOGENESIS OF OEDEMA OF THE OPTIC DISC (PAPILLOEDEMA): A PRELIMINARY REPORTBritish Journal of Ophthalmology, 1964