Llewellyn C. Padayachy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Llewellyn C. Padayachy has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
A. Graham Fieggen
University of Cape Town
4 shared publicationsUshma Galal
Department of Statistical Sciences, University of Cape Town, Cape Town, South Africa
2 shared publicationsVaishali Padayachy
Trauma Unit, Red Cross War Memorial Children's Hospital, University of Cape Town, Cape Town, South Africa
2 shared publications- Anthony Figaji
Neuroscience Institute, University of Cape Town, Cape Town, South Africa
1 shared publication - Anthony Graham Fieggen
Division of Neurosurgery, Department of Surgery, Groote Schuur Hospital and University of Cape Town, Cape Town, South Africa
1 shared publication Eugene Zwane
University of Swaziland
1 shared publication
Latest Publications
- 24 June 2020
- Published by Springer Nature
- p. 1285-1296
Birth-Related Head Traumas
- 28 June 2017
- Published by Springer Nature
- p. 1-17
Birth-Related Head Traumas
- 20 September 2016
- Published by Springer Nature in Child's Nervous System
- Vol. 32 (10) , 1779-1785
The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children.
Purpose To analyse the diagnostic accuracy of age-related optic nerve sheath diameter (ONSD) cut-off values in children for detecting raised intracranial pressure (ICP) and to assess the benefit of using patency of the anterior fontanelle in describing a different set of cut-off values. Methods The ONSD measurement was performed prior to invasive ICP measurement in children under general anesthesia. The diagnostic accuracy of the ONSD measurement was compared to ICP at thresholds of 20, 15, 10, and 5 mmHg. This was further analysed in children above and below the age of 1 year, with a subgroup analysis of age at 4 years, and assessment of the anterior fontanelle (AF) as a reliable physiological marker in part II of this study. Results Data from 174 children were analysed. In children ≤1 year old, the ONSD measurement with the best diagnostic accuracy for detecting ICP ≥ 20 mmHg was 5.16 mm, compared to 5.75 mm in children >1 year old (p < 0.001). In addition, patency of the anterior fontanelle (AF) was found to be a useful clinical marker for defining different ONSD cut-off values at ICP thresholds of 20, 15, 10 and 5 mmHg. Conclusion Transorbital ultrasound measurement of the ONSD is a reliable non-invasive marker of ICP particularly at higher thresholds of 20 and 15 mmHg. Patency of the AF is a useful clinical marker for defining different ONSD cut-off values in children.
- 20 September 2016
- Published by Springer Nature in Child's Nervous System
- Vol. 32 (10) , 1779-1785
The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children.
Purpose To analyse the diagnostic accuracy of age-related optic nerve sheath diameter (ONSD) cut-off values in children for detecting raised intracranial pressure (ICP) and to assess the benefit of using patency of the anterior fontanelle in describing a different set of cut-off values. Methods The ONSD measurement was performed prior to invasive ICP measurement in children under general anesthesia. The diagnostic accuracy of the ONSD measurement was compared to ICP at thresholds of 20, 15, 10, and 5 mmHg. This was further analysed in children above and below the age of 1 year, with a subgroup analysis of age at 4 years, and assessment of the anterior fontanelle (AF) as a reliable physiological marker in part II of this study. Results Data from 174 children were analysed. In children ≤1 year old, the ONSD measurement with the best diagnostic accuracy for detecting ICP ≥ 20 mmHg was 5.16 mm, compared to 5.75 mm in children >1 year old (p < 0.001). In addition, patency of the anterior fontanelle (AF) was found to be a useful clinical marker for defining different ONSD cut-off values at ICP thresholds of 20, 15, 10 and 5 mmHg. Conclusion Transorbital ultrasound measurement of the ONSD is a reliable non-invasive marker of ICP particularly at higher thresholds of 20 and 15 mmHg. Patency of the AF is a useful clinical marker for defining different ONSD cut-off values in children.
- 20 September 2016
- Published by Springer Nature in Child's Nervous System
- Vol. 32 (10) , 1769-1778
The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children
Purpose The aim of this study was to investigate the relationship between optic nerve sheath diameter (ONSD) measurement and invasively measured intracranial pressure (ICP) in children. Methods ONSD measurement was performed prior to invasive measurement of ICP. The mean binocular ONSD measurement was compared to the ICP reading. Physiological variables including systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), pulse rate, temperature, respiratory rate and end tidal carbon dioxide (ETCO2) level were recorded at the time of ONSD measurement. Diagnostic accuracy analysis was performed at various ICP thresholds and repeatability, intra- and inter-observer variability, correlation between measurements in different imaging planes as well the relationship over the entire patient cohort were examined in part I of this study. Results Data from 174 patients were analysed. Repeatability and intra-observer variability were excellent (α = 0.97–0.99). Testing for inter-observer variability revealed good correlation (r = 0.89, p < 0.001). Imaging in the sagittal plane demonstrated a slightly better correlation with ICP (r = 0.66, p < 0.001). The ONSD measurement with the best diagnostic accuracy for detecting an ICP ≥ 20 mmHg over the entire patient cohort was 5.5 mm, sensitivity 93.2 %, specificity 74 % and odds ratio (OR) of 39.3. Conclusion Transorbital ultrasound measurement of the OSND is a reliable and reproducible technique, demonstrating a good relationship with ICP and high diagnostic accuracy for detecting raised ICP.
- 20 September 2016
- Published by Springer Nature in Child's Nervous System
- Vol. 32 (10) , 1769-1778
The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children
Purpose The aim of this study was to investigate the relationship between optic nerve sheath diameter (ONSD) measurement and invasively measured intracranial pressure (ICP) in children. Methods ONSD measurement was performed prior to invasive measurement of ICP. The mean binocular ONSD measurement was compared to the ICP reading. Physiological variables including systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), pulse rate, temperature, respiratory rate and end tidal carbon dioxide (ETCO2) level were recorded at the time of ONSD measurement. Diagnostic accuracy analysis was performed at various ICP thresholds and repeatability, intra- and inter-observer variability, correlation between measurements in different imaging planes as well the relationship over the entire patient cohort were examined in part I of this study. Results Data from 174 patients were analysed. Repeatability and intra-observer variability were excellent (α = 0.97–0.99). Testing for inter-observer variability revealed good correlation (r = 0.89, p < 0.001). Imaging in the sagittal plane demonstrated a slightly better correlation with ICP (r = 0.66, p < 0.001). The ONSD measurement with the best diagnostic accuracy for detecting an ICP ≥ 20 mmHg over the entire patient cohort was 5.5 mm, sensitivity 93.2 %, specificity 74 % and odds ratio (OR) of 39.3. Conclusion Transorbital ultrasound measurement of the OSND is a reliable and reproducible technique, demonstrating a good relationship with ICP and high diagnostic accuracy for detecting raised ICP.
- 17 June 2012
- Published by Springer Nature in Child's Nervous System
- Vol. 28 (11) , 1911-1918
The frequency of cerebral ischemia/hypoxia in pediatric severe traumatic brain injury
The frequency of adverse events, such as cerebral ischemia, following traumatic brain injury (TBI) is often debated. Point-in-time monitoring modalities provide important information, but have limited temporal resolution.
- 17 June 2012
- Published by Springer Nature in Child's Nervous System
- Vol. 28 (11) , 1911-1918
The frequency of cerebral ischemia/hypoxia in pediatric severe traumatic brain injury
The frequency of adverse events, such as cerebral ischemia, following traumatic brain injury (TBI) is often debated. Point-in-time monitoring modalities provide important information, but have limited temporal resolution.