Abstract
The current prefabricated steel structure residences had the problems of complex structure and inflexible layout, which limited the development of prefabricated steel structure. In order to solve the problem of exposed columns in prefabricated steel structure residence, a new L-shaped Steel Lattice Column (L-SSLC) was proposed. A simplified formula for ultimate bearing capacity of L-SSLC was produced by double coefficient multiplication method. The nonlinear finite element analysis of L-SSLC was performed using ABAQUS software, in which the compression performance was analysed. Theoretical results calculated by simplified formula were compared to that of the finite element analysis. The results indicate that the stress at the connection between batten plates and steel pipes is relatively large. Compared to axial compression columns, eccentric compression columns have better ductility and lower bearing capacity. The simplified formula is feasible and the redundancy factor is 1.12-1.41.
Funding Information
  • Natural Science Foundation of Shandong Province
  • Ministry of Education