Yiying Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yiying Liu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Jinru Sun
State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China
1 shared publication - Lin Chen
Hunan University of Science and Technology
1 shared publication Linjie Wang
1 shared publication- Na Wang
Chaotic Matter Science Research Center, Department of Materials, Metallurgy and Chemistry, Jiangxi University of Science and Technology, Ganzhou 341000, P. R. China
1 shared publication Penghao Yu
Jiaxing Electric Power Supply Company, State Grid Zhejiang Electric Power Co., Ltd., Jiaxing, People’s Republic of China
1 shared publication- Penghui Yang
West China Second University Hospital, Sichuan University
1 shared publication
Latest Publications
- Open Access
- 29 August 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (17) , 9784
Investigation of Impulse Aging of Energy-Absorption Elements for Hybrid DC Circuit Breakers
The state of the energy-absorption branch MOV in the hybrid DC circuit breaker (DCCB) has a very important impact on the short fault breaking operation of the circuit breaker. Therefore, it is necessary to evaluate the state of the MOV, which is also called the “sleep component”. Due to DCCB being placed indoors, the aging is mainly caused by short-circuit impulse current. Therefore, this paper mainly focuses on the study of the short-circuit impulse aging characteristics of the energy-absorption branch MOV. The dynamic simulation system of a hybrid DCCB was built to investigate the impulse of short-circuit current on the MOV of the energy-absorption branch during the circuit breaking process. Then, an accelerated impulse aging test platform was built and the accelerated impulse aging tests of the MOV were conducted. The aging characteristics of the MOV were analyzed in detail and detailed analysis was conducted of the macroscopic parameters and microstructure changes. The results indicate that the nonlinear coefficient α could be emphasized as a basis for judging the “sleeping” component states and aging degree of the hybrid DC circuit breaker, and can be expected to be applicable to MOV condition monitoring of BCCB in the future.
- 29 August 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (17) , 9784
Open AccessInvestigation of Impulse Aging of Energy-Absorption Elements for Hybrid DC Circuit Breakers
The state of the energy-absorption branch MOV in the hybrid DC circuit breaker (DCCB) has a very important impact on the short fault breaking operation of the circuit breaker. Therefore, it is necessary to evaluate the state of the MOV, which is also called the “sleep component”. Due to DCCB being placed indoors, the aging is mainly caused by short-circuit impulse current. Therefore, this paper mainly focuses on the study of the short-circuit impulse aging characteristics of the energy-absorption branch MOV. The dynamic simulation system of a hybrid DCCB was built to investigate the impulse of short-circuit current on the MOV of the energy-absorption branch during the circuit breaking process. Then, an accelerated impulse aging test platform was built and the accelerated impulse aging tests of the MOV were conducted. The aging characteristics of the MOV were analyzed in detail and detailed analysis was conducted of the macroscopic parameters and microstructure changes. The results indicate that the nonlinear coefficient α could be emphasized as a basis for judging the “sleeping” component states and aging degree of the hybrid DC circuit breaker, and can be expected to be applicable to MOV condition monitoring of BCCB in the future.
- 10 August 2023
- Published by Elsevier in Measurement
- Vol. 220
Minimum Squared Error Method based on Modal Analysis for Acoustic Emission Source Location using Microfiber Coupler Sensor
- 10 August 2023
- Published by Elsevier in Measurement
- Vol. 220
Minimum Squared Error Method based on Modal Analysis for Acoustic Emission Source Location using Microfiber Coupler Sensor
- 6 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 363-366
Design Method and Mechanical Analysis of Fabricated L-shaped Steel Lattice Columns
The current prefabricated steel structure residences had the problems of complex structure and inflexible layout, which limited the development of prefabricated steel structure. In order to solve the problem of exposed columns in prefabricated steel structure residence, a new L-shaped Steel Lattice Column (L-SSLC) was proposed. A simplified formula for ultimate bearing capacity of L-SSLC was produced by double coefficient multiplication method. The nonlinear finite element analysis of L-SSLC was performed using ABAQUS software, in which the compression performance was analysed. Theoretical results calculated by simplified formula were compared to that of the finite element analysis. The results indicate that the stress at the connection between batten plates and steel pipes is relatively large. Compared to axial compression columns, eccentric compression columns have better ductility and lower bearing capacity. The simplified formula is feasible and the redundancy factor is 1.12-1.41.
- 6 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 363-366
Design Method and Mechanical Analysis of Fabricated L-shaped Steel Lattice Columns
The current prefabricated steel structure residences had the problems of complex structure and inflexible layout, which limited the development of prefabricated steel structure. In order to solve the problem of exposed columns in prefabricated steel structure residence, a new L-shaped Steel Lattice Column (L-SSLC) was proposed. A simplified formula for ultimate bearing capacity of L-SSLC was produced by double coefficient multiplication method. The nonlinear finite element analysis of L-SSLC was performed using ABAQUS software, in which the compression performance was analysed. Theoretical results calculated by simplified formula were compared to that of the finite element analysis. The results indicate that the stress at the connection between batten plates and steel pipes is relatively large. Compared to axial compression columns, eccentric compression columns have better ductility and lower bearing capacity. The simplified formula is feasible and the redundancy factor is 1.12-1.41.
- 21 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
The Study of Partial Discharge Localization in Transformer Oil Based on Coupling Optical Fiber Ultrasonic Sensor
Due to the initial defects, partial discharge (PD) will occur in the transformer, which will further deteriorate the internal insulation of the transformer and even the breakdown of the insulation system. Therefore, it is of great significance to accurately locate the PD in the transformer. At present, The piezoelectric sensor is widely used in PD ultrasonic localization. However, coupling optical fiber ultrasonic sensor (COFUS) is a good alternative for its strong anti-electromagnetic interference ability, low material cost and small structure. In this paper, an experimental system based on COFUS is proposed, and the localization algorithm is determined. Finally, the experiments of acoustic-acoustic localization and electro-acoustic localization are carried out. The results show that the average geometric errors are 54.14 mm and 45.14 mm respectively. That is, the localization results have high localization accuracy. Therefore, the COFUS has a broad application prospect in PD localization of transformer.
- 21 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
The Study of Partial Discharge Localization in Transformer Oil Based on Coupling Optical Fiber Ultrasonic Sensor
Due to the initial defects, partial discharge (PD) will occur in the transformer, which will further deteriorate the internal insulation of the transformer and even the breakdown of the insulation system. Therefore, it is of great significance to accurately locate the PD in the transformer. At present, The piezoelectric sensor is widely used in PD ultrasonic localization. However, coupling optical fiber ultrasonic sensor (COFUS) is a good alternative for its strong anti-electromagnetic interference ability, low material cost and small structure. In this paper, an experimental system based on COFUS is proposed, and the localization algorithm is determined. Finally, the experiments of acoustic-acoustic localization and electro-acoustic localization are carried out. The results show that the average geometric errors are 54.14 mm and 45.14 mm respectively. That is, the localization results have high localization accuracy. Therefore, the COFUS has a broad application prospect in PD localization of transformer.