Considerations in high‐resolution skeletal muscle diffusion tensor imaging using single‐shot echo planar imaging with stimulated‐echo preparation and sensitivity encoding
- 11 November 2011
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 25 (5) , 766-778
Abstract
Previous studies have shown that skeletal muscle diffusion tensor imaging (DTI) can noninvasively probe changes in the muscle fiber architecture and microstructure in diseased and damaged muscles. However, DTI fiber reconstruction in small muscles and in muscle regions close to aponeuroses and tendons remains challenging because of partial volume effects. Increasing the spatial resolution of skeletal muscle single‐shot diffusion‐weighted echo planar imaging (DW‐EPI) can be hindered by the inherently low signal‐to‐noise ratio (SNR) of muscle DW‐EPI because of the short muscle T2 and the high sensitivity of single‐shot EPI to off‐resonance effects and T2* blurring. In this article, eddy current‐compensated diffusion‐weighted stimulated‐echo preparation is combined with sensitivity encoding (SENSE) to maintain good SNR properties and to reduce the sensitivity to distortions and T2* blurring in high‐resolution skeletal muscle single‐shot DW‐EPI. An analytical framework is developed to optimize the reduction factor and diffusion weighting time to achieve maximum SNR. Arguments for the selection of the experimental parameters are then presented considering the compromise between SNR, B0‐induced distortions, T2* blurring effects and tissue incoherent motion effects. On the basis of the selected parameters in a high‐resolution skeletal muscle single‐shot DW‐EPI protocol, imaging protocols at lower acquisition matrix sizes are defined with matched bandwidth in the phase‐encoding direction and SNR. In vivo results show that high‐resolution skeletal muscle DTI with minimized sensitivity to geometric distortions and T2* blurring is feasible using the proposed methodology. In particular, a significant benefit is demonstrated from a reduction in partial volume effects for resolving multi‐pennate muscles and muscles with small cross‐sections in calf muscle DTI. Copyright © 2011 John Wiley & Sons, Ltd.Keywords
This publication has 61 references indexed in Scilit:
- Human soleus muscle architecture at different ankle joint angles from magnetic resonance diffusion tensor imagingJournal of Applied Physiology, 2011
- Removal of olefinic fat chemical shift artifact in diffusion MRIMagnetic Resonance in Medicine, 2010
- Repeatability of DTI‐based skeletal muscle fiber trackingNMR in Biomedicine, 2010
- Robust GRAPPA‐accelerated diffusion‐weighted readout‐segmented (RS)‐EPIMagnetic Resonance in Medicine, 2009
- DTI‐based muscle fiber tracking of the quadriceps mechanism in lateral patellar dislocationJournal of Magnetic Resonance Imaging, 2009
- Quantitative assessment of DTI‐based muscle fiber tracking and optimal tracking parametersMagnetic Resonance in Medicine, 2009
- Effects of image noise in muscle diffusion tensor (DT)‐MRI assessed using numerical simulationsMagnetic Resonance in Medicine, 2008
- Magnetic resonance imaging of mouse skeletal muscle to measure denervation atrophyExperimental Neurology, 2008
- Compartmental relaxation and diffusion tensor imaging measurements in vivo in λ‐carrageenan‐induced edema in rat skeletal muscleNMR in Biomedicine, 2007
- Iterative decomposition of water and fat with echo asymmetry and least‐squares estimation (IDEAL): Application with fast spin‐echo imagingMagnetic Resonance in Medicine, 2005