Numerical Analysis of the Behavior of an IPM Bridge According to Super-Structure and Sub-Structure Properties
Open Access
- 15 March 2018
- journal article
- research article
- Published by MDPI AG in Sustainability
- Vol. 10 (3) , 833
Abstract
A bridge with an integrated and pile-bent abutment with a mechanically stabilized earth-wall (IPM) was developed by separating earth pressure from the abutment to overcome the problems typically faced by integral abutment bridges. Also, the IPM bridge removes expansion joints and bearing by integrating the super-structure and the abutment and does not need many piles because it separates the earth pressure from backfills. Therefore, it is superior in cost, durability, and maintainability to traditional bridges and is sustainable due to using less material. A numerical analysis was conducted to ascertain the behavior of the IPM bridge according to its super-structural and sub-structural characteristics. Based on the analysis results, the behaviors of the IPM bridge are as follows: The bending moments
of the pre-stressed concrete (PSC) girder and the steel-plate girder of the bridge were influenced by the presence of the time-dependent loads. The contraction behavior in the PSC girder is largely due to the time-dependent loads, whereas the expansion behavior in the steel-plate girder is large due to its greater thermal expansion coefficient and temperature range compared with those of the PSC girder. In general, the suggested bridge length limit for PSC girders in both the integral abutment bridge and the IPM bridge is larger than that in a steel bridge. This needs to be reviewed again with consideration of the long-term and seasonal behaviors.
Keywords
This publication has 29 references indexed in Scilit:
- Numerical Simulations of Steel Integral Abutment Bridges under Thermal LoadingJournal of Bridge Engineering, 2016
- Seismic Response and Performance Evaluation of Self-Centering LRB Isolators Installed on the CBF Building under NF Ground MotionsSustainability, 2016
- Response of Seismically Isolated Steel Frame Buildings with Sustainable Lead-Rubber Bearing (LRB) Isolator Devices Subjected to Near-Fault (NF) Ground MotionsSustainability, 2014
- Integral abutment bridge response under thermal loadingEngineering Structures, 2010
- Effect of Soil and Substructure Properties on Live-Load Distribution in Integral Abutment BridgesJournal of Bridge Engineering, 2008
- Evaluation of Seasonal and Yearly Behavior of an Integral Abutment BridgeJournal of Bridge Engineering, 2007
- Integral Abutment Bridge Behavior: Parametric Analysis of a Massachusetts BridgeJournal of Bridge Engineering, 2007
- Predicted and Measured Response of an Integral Abutment BridgeJournal of Bridge Engineering, 2005
- Effect of cyclic thermal loading on the performance of steel H-piles in integral bridges with stub-abutmentsJournal of Constructional Steel Research, 2004