Abstract
This study presents a theoretical analysis of wastewater's potential as a renewable thermal energy source for preparing domestic hot water (DHW) using a small-scale transcritical R744 heat pump equipped with an adjustable-needle ejector. A stochastic model of wastewater temperature and flow was developed based on measured residential water consumption data and was integrated with detailed thermodynamic models of individual heat pump components to predict system performance under varying operating conditions. The mathematical model was implemented in MATLAB its performance was evaluated through a physical system model implemented in the Simscape environment, which replicated a residential building accommodating 12 occupants, with an average daily wastewater generation of 107 L per person per day at 35.82 °C. Two operating strategies were analyzed: one optimized for maximum coefficient of performance (COP) and the other aimed at minimal electrical input. The "Best COP" configuration achieved a COP of 3.17 with a heating capacity of 6.06 kW, while the low-power variant attained a COP of 2.99 with a heating capacity of 3.50 kW. In both cases, the DHW demand was fully met without the need for auxiliary heating, and surplus thermal energy was supplied to space heating storage. Simulation results indicated that the heat content of wastewater exceeded daily DHW requirements, confirming its viability as a continuous low-grade heat source.