Andrej Kapjor
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Andrej Kapjor has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Martin Vantúch
Department of Power Engineering, Faculty of Mechanical Engineering, University of Zilina, Univerzitna 8215/1, 010 26 Zilina, Slovakia
6 shared publications - Michal Holubčík
Department of Power Engineering, Faculty of Mechanical Engineering, University of Zilina, Zilina, Slovakia
4 shared publications - Lidia Dąbek
Kielce University of Technology, Kielce, Poland
3 shared publications - Marcel Novomestský
University of Žilina, Faculty of mechanical engineering, Department of power engineering, Univerzitná 1, 010 26 Žilina, Slovakia
3 shared publications - Peter Durcansky
Department of Power Engineering, Faculty of Mechanical Engineering, University of Zilina, 010 26 Zilina, Slovakia
3 shared publications - Łukasz Jan Orman
Kielce University of Technology, Kielce, Poland
3 shared publications
Latest Publications
- Open Access
- 14 March 2026
- Published by Elsevier in SSRN Electronic Journal
Theoretical Analysis of Wastewater Heat Recovery Using a Transcritical CO₂ Heat Pump with an Adjustable-Needle Ejector
This study presents a theoretical analysis of wastewater's potential as a renewable thermal energy source for preparing domestic hot water (DHW) using a small-scale transcritical R744 heat pump equipped with an adjustable-needle ejector. A stochastic model of wastewater temperature and flow was developed based on measured residential water consumption data and was integrated with detailed thermodynamic models of individual heat pump components to predict system performance under varying operating conditions. The mathematical model was implemented in MATLAB its performance was evaluated through a physical system model implemented in the Simscape environment, which replicated a residential building accommodating 12 occupants, with an average daily wastewater generation of 107 L per person per day at 35.82 °C. Two operating strategies were analyzed: one optimized for maximum coefficient of performance (COP) and the other aimed at minimal electrical input. The "Best COP" configuration achieved a COP of 3.17 with a heating capacity of 6.06 kW, while the low-power variant attained a COP of 2.99 with a heating capacity of 3.50 kW. In both cases, the DHW demand was fully met without the need for auxiliary heating, and surplus thermal energy was supplied to space heating storage. Simulation results indicated that the heat content of wastewater exceeded daily DHW requirements, confirming its viability as a continuous low-grade heat source.
- 14 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessTheoretical Analysis of Wastewater Heat Recovery Using a Transcritical CO₂ Heat Pump with an Adjustable-Needle Ejector
This study presents a theoretical analysis of wastewater's potential as a renewable thermal energy source for preparing domestic hot water (DHW) using a small-scale transcritical R744 heat pump equipped with an adjustable-needle ejector. A stochastic model of wastewater temperature and flow was developed based on measured residential water consumption data and was integrated with detailed thermodynamic models of individual heat pump components to predict system performance under varying operating conditions. The mathematical model was implemented in MATLAB its performance was evaluated through a physical system model implemented in the Simscape environment, which replicated a residential building accommodating 12 occupants, with an average daily wastewater generation of 107 L per person per day at 35.82 °C. Two operating strategies were analyzed: one optimized for maximum coefficient of performance (COP) and the other aimed at minimal electrical input. The "Best COP" configuration achieved a COP of 3.17 with a heating capacity of 6.06 kW, while the low-power variant attained a COP of 2.99 with a heating capacity of 3.50 kW. In both cases, the DHW demand was fully met without the need for auxiliary heating, and surplus thermal energy was supplied to space heating storage. Simulation results indicated that the heat content of wastewater exceeded daily DHW requirements, confirming its viability as a continuous low-grade heat source.
- Open Access
- 1 December 2024
- Published by Walter de Gruyter GmbH in System Safety: Human - Technical Facility - Environment
- Vol. 6 (1) , 289-298
Reducing the Energy Consumption of the Air Conditioning System in Clean Rooms Using the Idle Mode
Cleanrooms, essential in various industries, demand strictly controlled environmental conditions, which significantly impact building energy consumption. High-efficiency air handling systems are crucial in these environments to ensure a continuous supply of clean air and removal of contaminants. However, the substantial energy requirements of these systems pose a significant challenge to sustainable operations. This study focuses on an innovative approach to reduce the energy consumption of air handling systems in cleanrooms through the optimization of laminar airflow. Laminar flow, renowned for its high particle capture efficiency, is commonly employed in cleanrooms. Nevertheless, its operation is energy-intensive. It was proposed a novel concept involving the segmentation of the laminar flow field and the variable adjustment of airflow velocity within individual segments. This approach enables more flexible adaptation of airflow to specific operational requirements while reducing the overall volume of air that needs to be filtered and conditioned. Experimental results demonstrate that the proposed system can significantly reduce the energy consumption of the air handling system without compromising cleanliness. Compared to conventional systems, energy consumption was reduced by up to 60% in winter and 56% in summer, while simultaneously improving air quality in the critical area above the operating table.
- 1 December 2024
- Published by Walter de Gruyter GmbH in System Safety: Human - Technical Facility - Environment
- Vol. 6 (1) , 289-298
Open AccessReducing the Energy Consumption of the Air Conditioning System in Clean Rooms Using the Idle Mode
Cleanrooms, essential in various industries, demand strictly controlled environmental conditions, which significantly impact building energy consumption. High-efficiency air handling systems are crucial in these environments to ensure a continuous supply of clean air and removal of contaminants. However, the substantial energy requirements of these systems pose a significant challenge to sustainable operations. This study focuses on an innovative approach to reduce the energy consumption of air handling systems in cleanrooms through the optimization of laminar airflow. Laminar flow, renowned for its high particle capture efficiency, is commonly employed in cleanrooms. Nevertheless, its operation is energy-intensive. It was proposed a novel concept involving the segmentation of the laminar flow field and the variable adjustment of airflow velocity within individual segments. This approach enables more flexible adaptation of airflow to specific operational requirements while reducing the overall volume of air that needs to be filtered and conditioned. Experimental results demonstrate that the proposed system can significantly reduce the energy consumption of the air handling system without compromising cleanliness. Compared to conventional systems, energy consumption was reduced by up to 60% in winter and 56% in summer, while simultaneously improving air quality in the critical area above the operating table.
- Open Access
- 1 January 2023
- Published by Energeticka konzultacna agentura n.o. in Advances in Thermal Processes and Energy Transformation
- Vol. 6 (1) , 8-12
Investigating the Dependence of the Transmitted Heat Output on the Position and Diameter of the Gravity Heat Pipe
- 1 January 2023
- Published by Energeticka konzultacna agentura n.o. in Advances in Thermal Processes and Energy Transformation
- Vol. 6 (1) , 8-12
Open AccessInvestigating the Dependence of the Transmitted Heat Output on the Position and Diameter of the Gravity Heat Pipe
- Open Access
Polymer Membranes for Enthalpy Exchangers
A membrane-based enthalpy exchanger is a device used for heat and humidity recovery in ventilated buildings. The energy-saving potential of such a device is dependent on the parameters responsible for heat and moisture recovery. The trend is toward composite membranes, which are custom produced, and their parameters can be adjusted for a given application; therefore, the diffusion and sorption characteristics of such membranes are unknown. In order to obtain the values of the water vapor diffusivity of three investigated handmade membranes, a serial resistance model using a Field and Laboratory Emission Cell (FLEC) is proposed. Experiments were conducted to identify the resistance in each step of the moisture transfer process to extract the moisture diffusivity in the membranes. The calculated moisture diffusivities in the membranes were 8.99 × 10−12 (m2/s) for the membranes from cellulose acetate, 1.9 × 10−10 (m2/s) for the microporous PE/PUR membranes, and 1.53 × 10−11 (m2/s) for the PET/PUR microfibrous membranes. The obtained membrane diffusivities were then used in the proposed effectiveness-NTU-based model of an exchanger with a cross-flow arrangement to predict performance under various operating conditions. The results show that the highest latent effectiveness was found for the exchanger core made from the PE/PUR membrane and the lowest was for the one with the PE/PUR membrane core.
Open AccessPolymer Membranes for Enthalpy Exchangers
A membrane-based enthalpy exchanger is a device used for heat and humidity recovery in ventilated buildings. The energy-saving potential of such a device is dependent on the parameters responsible for heat and moisture recovery. The trend is toward composite membranes, which are custom produced, and their parameters can be adjusted for a given application; therefore, the diffusion and sorption characteristics of such membranes are unknown. In order to obtain the values of the water vapor diffusivity of three investigated handmade membranes, a serial resistance model using a Field and Laboratory Emission Cell (FLEC) is proposed. Experiments were conducted to identify the resistance in each step of the moisture transfer process to extract the moisture diffusivity in the membranes. The calculated moisture diffusivities in the membranes were 8.99 × 10−12 (m2/s) for the membranes from cellulose acetate, 1.9 × 10−10 (m2/s) for the microporous PE/PUR membranes, and 1.53 × 10−11 (m2/s) for the PET/PUR microfibrous membranes. The obtained membrane diffusivities were then used in the proposed effectiveness-NTU-based model of an exchanger with a cross-flow arrangement to predict performance under various operating conditions. The results show that the highest latent effectiveness was found for the exchanger core made from the PE/PUR membrane and the lowest was for the one with the PE/PUR membrane core.
- Open Access
- 26 February 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (5) , 2466
Impact of the Speed of Airflow in a Cleanroom on the Degree of Air Pollution
The high-energy requirements of cleanrooms are the main motivation for optimizing their operational conditions. The ventilation system consumes the most energy in order to ensure the precise air conditioning of the room (filtration, temperature, and humidity adjustment). The main function of the ventilation system is to keep particle concentration to a minimum. This work deals with the optimization of an experimental operating room via the optimization of air supply through the distribution element (laminar airflow ceiling) in the range of 0.15–0.25 m·s−1. The laminar airflow between the distribution element and the patient is influenced by the operating light and different airflow velocities. These factors affect changes in particle concentration. Ansys Fluent software was used to investigate the nature of the flow, velocity profiles, and particle trajectories. The results of our numerical simulation demonstrate that a suitable flow rate setting increases the efficiency of particle reduction in the operating table area by up to 54%, which can, in turn, reduce operating costs. The simulated air velocity profile was subsequently verified using the particle image velocimetry (PIV) method. The typical size of particles monitored for in cleanrooms is 0.5 μm according to ISO EN 7. Therefore, the results of this study should be helpful in correctly designing distribution elements for clean rooms.
- 26 February 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (5) , 2466
Open AccessImpact of the Speed of Airflow in a Cleanroom on the Degree of Air Pollution
The high-energy requirements of cleanrooms are the main motivation for optimizing their operational conditions. The ventilation system consumes the most energy in order to ensure the precise air conditioning of the room (filtration, temperature, and humidity adjustment). The main function of the ventilation system is to keep particle concentration to a minimum. This work deals with the optimization of an experimental operating room via the optimization of air supply through the distribution element (laminar airflow ceiling) in the range of 0.15–0.25 m·s−1. The laminar airflow between the distribution element and the patient is influenced by the operating light and different airflow velocities. These factors affect changes in particle concentration. Ansys Fluent software was used to investigate the nature of the flow, velocity profiles, and particle trajectories. The results of our numerical simulation demonstrate that a suitable flow rate setting increases the efficiency of particle reduction in the operating table area by up to 54%, which can, in turn, reduce operating costs. The simulated air velocity profile was subsequently verified using the particle image velocimetry (PIV) method. The typical size of particles monitored for in cleanrooms is 0.5 μm according to ISO EN 7. Therefore, the results of this study should be helpful in correctly designing distribution elements for clean rooms.
- Open Access
Experimental Simulation of Hydrate Formation Process in a Circulating Device
This paper focuses on the model of gas hydrate formation in an experimental device, which allows the circulation of the resulting mixture (water and gas) and significantly accelerates the process of hydrate formation in the laboratory. A 3D model was developed to better imagine the placement of individual parts of the device. The kinetics of hydrate formation were predicted from equilibrium values of chemical potentials. The aim of solving the equations of state gases in the mathematical model was to optimize the parameters involved in the formation of hydrates. The prediction of the mathematical model was verified by numerical simulation. The mathematical model and numerical simulation predict the chemical reaction evolving over time and determine the amount of crystallized water in the reactor. A remarkable finding is that the deviation of the model and simulation at the initiation the calculation of crystallized water starts at 76% and decreases over time to 2%. Subsequently, the number of moles of bound gas in the hydrate acquires the same percentage deviations. The amount of water supplied to the reactor is expressed by both methods identically with a maximum deviation of 0.10%. The different character is shown by the number of moles of gas remaining in the reactor. At the beginning of the calculation, the deviation of both methods is 0%, but over time the deviation slowly increases, and at the end it expresses the number of moles in the reactor with a deviation of 0.14%. By previous detection, we can confirm that the model successfully determines the amount of methane hydrate formed in the reactor of the experimental equipment. With the attached pictures from the realized experiment, we confirmed that the proposed method of hydrate production is tested and takes minutes. The article calculates the energy efficiency of natural gas hydrate in the proposed experimental device.
Open AccessExperimental Simulation of Hydrate Formation Process in a Circulating Device
This paper focuses on the model of gas hydrate formation in an experimental device, which allows the circulation of the resulting mixture (water and gas) and significantly accelerates the process of hydrate formation in the laboratory. A 3D model was developed to better imagine the placement of individual parts of the device. The kinetics of hydrate formation were predicted from equilibrium values of chemical potentials. The aim of solving the equations of state gases in the mathematical model was to optimize the parameters involved in the formation of hydrates. The prediction of the mathematical model was verified by numerical simulation. The mathematical model and numerical simulation predict the chemical reaction evolving over time and determine the amount of crystallized water in the reactor. A remarkable finding is that the deviation of the model and simulation at the initiation the calculation of crystallized water starts at 76% and decreases over time to 2%. Subsequently, the number of moles of bound gas in the hydrate acquires the same percentage deviations. The amount of water supplied to the reactor is expressed by both methods identically with a maximum deviation of 0.10%. The different character is shown by the number of moles of gas remaining in the reactor. At the beginning of the calculation, the deviation of both methods is 0%, but over time the deviation slowly increases, and at the end it expresses the number of moles in the reactor with a deviation of 0.14%. By previous detection, we can confirm that the model successfully determines the amount of methane hydrate formed in the reactor of the experimental equipment. With the attached pictures from the realized experiment, we confirmed that the proposed method of hydrate production is tested and takes minutes. The article calculates the energy efficiency of natural gas hydrate in the proposed experimental device.
- Open Access
Experimental Verification of CFD Simulation When Evaluating the Operative Temperature and Mean Radiation Temperature for Radiator Heating and Floor Heating
The assessment of heating systems is not only interested in the efficiency of the heating system itself, but also in the quality of the environment that the heating system creates. The quality of the environment and the heat-humidity microclimate is closely related to thermal comfort. A suitable environment has a positive effect, for example, on the efficiency of work at the workplace. The range of temperatures, humidity and operating temperatures in workplaces is often also legally prescribed in such a way that there is no thermal discomfort for users in the heated space. In terms of savings, it is therefore best to use heating systems that can create a comfortable environment with the lowest possible energy costs. During their development, variations are possible with temperature gradients, the size of the heat exchange area, or the ratio of the radiant and convective components of heat transfer. When developing such systems, it is appropriate to consider CFD simulations. The comparison of the results of CFD simulation and experimental measurement is also in the following article, where the comparison of the operating temperature and the mean radiation temperature of two different heating systems in the model office is monitored.
Open AccessExperimental Verification of CFD Simulation When Evaluating the Operative Temperature and Mean Radiation Temperature for Radiator Heating and Floor Heating
The assessment of heating systems is not only interested in the efficiency of the heating system itself, but also in the quality of the environment that the heating system creates. The quality of the environment and the heat-humidity microclimate is closely related to thermal comfort. A suitable environment has a positive effect, for example, on the efficiency of work at the workplace. The range of temperatures, humidity and operating temperatures in workplaces is often also legally prescribed in such a way that there is no thermal discomfort for users in the heated space. In terms of savings, it is therefore best to use heating systems that can create a comfortable environment with the lowest possible energy costs. During their development, variations are possible with temperature gradients, the size of the heat exchange area, or the ratio of the radiant and convective components of heat transfer. When developing such systems, it is appropriate to consider CFD simulations. The comparison of the results of CFD simulation and experimental measurement is also in the following article, where the comparison of the operating temperature and the mean radiation temperature of two different heating systems in the model office is monitored.
- Open Access
- 4 June 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (11) , 5239
Small Heat Source Used for Combustion of Wheat-Straw Pellets
Wheat straw, as a secondary waste agricultural product, presents a potential renewable source of energy. It is necessary to design simple heat sources to achieve better usage. As part of an analysis of heat sources, a tubular type of heat exchanger was reviewed. The design of the exchanger was focused on the smallest possible dimensional requirements, low costs, high reliability and easy maintenance. We chose a tubular type of heat exchanger. In our case, flue gas flows through the tubes, and water flows outside of the tubes. This type of exchanger allows for continuous cleaning, but also simple maintenance, even in case of equipment failure. It is possible to replace individual parts (pipes) of equipment that are exposed to the adverse corrosive effects of biomass flue gases. A mathematical model was composed to compute the construction of a heat source. The model was verified by CFD simulation. The main idea of this design is modularity. The composed model can be used to design a series of similar heat sources with different levels of power, and which, as it is of maximal availability for this type of construction, increase use of waste straw as fuel by small farms.
- 4 June 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (11) , 5239
Open AccessSmall Heat Source Used for Combustion of Wheat-Straw Pellets
Wheat straw, as a secondary waste agricultural product, presents a potential renewable source of energy. It is necessary to design simple heat sources to achieve better usage. As part of an analysis of heat sources, a tubular type of heat exchanger was reviewed. The design of the exchanger was focused on the smallest possible dimensional requirements, low costs, high reliability and easy maintenance. We chose a tubular type of heat exchanger. In our case, flue gas flows through the tubes, and water flows outside of the tubes. This type of exchanger allows for continuous cleaning, but also simple maintenance, even in case of equipment failure. It is possible to replace individual parts (pipes) of equipment that are exposed to the adverse corrosive effects of biomass flue gases. A mathematical model was composed to compute the construction of a heat source. The model was verified by CFD simulation. The main idea of this design is modularity. The composed model can be used to design a series of similar heat sources with different levels of power, and which, as it is of maximal availability for this type of construction, increase use of waste straw as fuel by small farms.
- Open Access
Effect of Heat Source Placement on Natural Convection from Cylindrical Surfaces
Placement of heat source can play a significant role in final heat output, or heat source effectivity. Because of this, there is a need to analyze thermal fields of the heat exchange system by natural convection, where the description by criterion equations is desired, as the net heat output from tubes can be quantified. Based on known theoretical models, numerical methods were adapted to calculate the heat output with natural air flow around tubes, where mathematical models were used to describe the heat transfer more precisely. After validation of heat transfer coefficients, the effect of wall and heat source placement was studied, and the Coanda effect was also observed. The heat source placement also has an effect at the boundary layer, which can change and therefore affect the overall heat transfer process. The optimal wall-to-cylinder distance for an array of horizontal cylinders near a wall was also expressed as a function of the Rayleigh number and number of cylinders in the array.
Open AccessEffect of Heat Source Placement on Natural Convection from Cylindrical Surfaces
Placement of heat source can play a significant role in final heat output, or heat source effectivity. Because of this, there is a need to analyze thermal fields of the heat exchange system by natural convection, where the description by criterion equations is desired, as the net heat output from tubes can be quantified. Based on known theoretical models, numerical methods were adapted to calculate the heat output with natural air flow around tubes, where mathematical models were used to describe the heat transfer more precisely. After validation of heat transfer coefficients, the effect of wall and heat source placement was studied, and the Coanda effect was also observed. The heat source placement also has an effect at the boundary layer, which can change and therefore affect the overall heat transfer process. The optimal wall-to-cylinder distance for an array of horizontal cylinders near a wall was also expressed as a function of the Rayleigh number and number of cylinders in the array.
- Open Access
- 13 November 2019
- Published by EDP Sciences in Mechanics & Industry
- Vol. 20 (7) , 701
Distilled water and ethyl alcohol boiling heat transfer on selected meshed surfaces
The article deals with the problem of pool boiling heat transfer enhancement on metal wire mesh coatings made of copper and phosphor bronze at nucleate boiling of distilled water and high purity ethyl alcohol under ambient pressure. The tests have been performed on horizontal samples containing different microstructures produced with the sintering technology. The samples were attached to the heating block with soldering. As a result of the experiments, boiling curves were obtained, describing the relationship between the dissipated heat flux and the superheat values for each specimen. A considerable augmentation of heat flux has been recorded for the meshed surfaces in relation to the smooth reference surface without any coating. Generally, the highest enhancement was recorded for the low superheat values. The presented test results have been discussed and then compared with selected correlations available in literature for nucleate boiling heat transfer on microstructure coated surfaces.
- 13 November 2019
- Published by EDP Sciences in Mechanics & Industry
- Vol. 20 (7) , 701
Open AccessDistilled water and ethyl alcohol boiling heat transfer on selected meshed surfaces
The article deals with the problem of pool boiling heat transfer enhancement on metal wire mesh coatings made of copper and phosphor bronze at nucleate boiling of distilled water and high purity ethyl alcohol under ambient pressure. The tests have been performed on horizontal samples containing different microstructures produced with the sintering technology. The samples were attached to the heating block with soldering. As a result of the experiments, boiling curves were obtained, describing the relationship between the dissipated heat flux and the superheat values for each specimen. A considerable augmentation of heat flux has been recorded for the meshed surfaces in relation to the smooth reference surface without any coating. Generally, the highest enhancement was recorded for the low superheat values. The presented test results have been discussed and then compared with selected correlations available in literature for nucleate boiling heat transfer on microstructure coated surfaces.