Intrastromal corneal ring segments: visual outcomes from a large case series
- 8 September 2011
- journal article
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 40 (5) , 433-439
Abstract
Background: To evaluate the clinical safety and efficacy of implanted Ferrara intrastromal corneal ring segments in a large sample of patients with ectatic corneal disease.Design: Retrospective, consecutive case series.Samples: A total of 1073 eyes of 810 patients consecutively operated from January 2006 to July 2008 were evaluated.Methods: Two groups were created according to the type of ring implanted: Group 1 – patients implanted with the 160° of arc ring – and Group 2 – patients implanted with the 210° of arc ring.Main Outcome Measures: Uncorrected visual acuity, best‐corrected visual acuity, keratometry, asphericity and pachymetry at the thinnest point of the cornea. All patients were evaluated using a corneal tomography (Pentacam, Oculus, Inc., Lynnwood, WA, USA).Results: For Group 1 patients, uncorrected visual acuity increased to 20/80, best‐corrected visual acuity increased to 20/40, asphericity decreased to −0.35, spherical equivalent decreased to −2.26 D and keratometry decreased to 45.72 D (P < 0.001 for each compared with preoperative values). For Group 2 patients, uncorrected visual acuity increased to 20/130, best‐corrected visual acuity increased to 20/60, asphericity decreased to −0.56, spherical equivalent decreased to −4.14 D and keratometry decreased to 48.10 D (P < 0.001 for each compared with preoperative values). The 210° intrastromal corneal ring segments reduced keratometry and asphericity more than the 160° intrastromal corneal ring segments did. The complication rate was 3.82%.Conclusions: Ferrara intrastromal corneal ring segments implantation is safe and effective and has a low complication rate. It can effectively reduce the corneal steepening and improve uncorrected visual acuity and best‐corrected visual acuity in patients with keratoconus.Keywords
This publication has 26 references indexed in Scilit:
- Reasons for intrastromal corneal ring segment explantationJournal of Cataract & Refractive Surgery, 2010
- Mechanical Strain Stabilizes Reconstituted Collagen Fibrils against Enzymatic Degradation by Mammalian Collagenase Matrix Metalloproteinase 8 (MMP-8)PLOS ONE, 2010
- Long-term follow-up of intrastromal corneal ring segments in keratoconusJournal of Cataract & Refractive Surgery, 2009
- Intracorneal ring segment implantation for the management of keratoconus: Safety and efficacyJournal of Cataract & Refractive Surgery, 2007
- Intracorneal ring segments for keratoconus correction: Long-term follow-upJournal of Cataract & Refractive Surgery, 2006
- Collagenolytic Proteinases in KeratoconusCornea, 2006
- Corneal Asphericity and Apical Curvature in Children: A Cross-sectional and Longitudinal EvaluationInvestigative Ophthalmology & Visual Science, 2005
- Asfericidad corneal en una población de adultos jóvenes: Implicaciones clínicasArchivos de la Sociedad Española de Oftalmología, 2004
- Correction of astigmatism with short arc- length intrastromal corneal ring segmentsOphthalmology, 2003
- Utilização do Anel de Ferrara na estabilização e correção da ectasia corneana pós PRKArquivos Brasileiros de Oftalmologia, 2000