Guilherme Ferrara
Research Subjects
Research Interests
Guilherme Ferrara has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Paulo Ferrara
Paulo Ferrara Eye Clinic
3 shared publications Jesús Merayo‐Lloves
Fernandez-Vega Eye Institute, Oviedo, Spain
1 shared publicationLeonardo Torquetti
Paulo Ferrara Eye Clinic, Belo Horizonte, Brazil
1 shared publicationPaulo Ferrara
Paulo Ferrara Eye Clinic, Belo Horizonte, Brazil
1 shared publication
Latest Publications
- 28 October 2022
- Published by Springer Nature
- p. 487-498
History of the Ferrara Ring
- 28 October 2022
- Published by Springer Nature
- p. 703-715
Intrastromal Corneal Ring Segment Implantation in Children with Keratoconus
- 28 October 2022
- Published by Springer Nature
- p. 703-715
Intrastromal Corneal Ring Segment Implantation in Children with Keratoconus
- 28 October 2022
- Published by Springer Nature
- p. 969-978
Femtosecond Laser–Assisted Intrastromal Corneal Lenticule Implantation for Treatment of Advanced Keratoconus
- 28 October 2022
- Published by Springer Nature
- p. 969-978
Femtosecond Laser–Assisted Intrastromal Corneal Lenticule Implantation for Treatment of Advanced Keratoconus
- 8 September 2011
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 40 (5) , 433-439
Intrastromal corneal ring segments: visual outcomes from a large case series
Background: To evaluate the clinical safety and efficacy of implanted Ferrara intrastromal corneal ring segments in a large sample of patients with ectatic corneal disease.Design: Retrospective, consecutive case series.Samples: A total of 1073 eyes of 810 patients consecutively operated from January 2006 to July 2008 were evaluated.Methods: Two groups were created according to the type of ring implanted: Group 1 – patients implanted with the 160° of arc ring – and Group 2 – patients implanted with the 210° of arc ring.Main Outcome Measures: Uncorrected visual acuity, best‐corrected visual acuity, keratometry, asphericity and pachymetry at the thinnest point of the cornea. All patients were evaluated using a corneal tomography (Pentacam, Oculus, Inc., Lynnwood, WA, USA).Results: For Group 1 patients, uncorrected visual acuity increased to 20/80, best‐corrected visual acuity increased to 20/40, asphericity decreased to −0.35, spherical equivalent decreased to −2.26 D and keratometry decreased to 45.72 D (P < 0.001 for each compared with preoperative values). For Group 2 patients, uncorrected visual acuity increased to 20/130, best‐corrected visual acuity increased to 20/60, asphericity decreased to −0.56, spherical equivalent decreased to −4.14 D and keratometry decreased to 48.10 D (P < 0.001 for each compared with preoperative values). The 210° intrastromal corneal ring segments reduced keratometry and asphericity more than the 160° intrastromal corneal ring segments did. The complication rate was 3.82%.Conclusions: Ferrara intrastromal corneal ring segments implantation is safe and effective and has a low complication rate. It can effectively reduce the corneal steepening and improve uncorrected visual acuity and best‐corrected visual acuity in patients with keratoconus.
- 8 September 2011
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 40 (5) , 433-439
Intrastromal corneal ring segments: visual outcomes from a large case series
Background: To evaluate the clinical safety and efficacy of implanted Ferrara intrastromal corneal ring segments in a large sample of patients with ectatic corneal disease.Design: Retrospective, consecutive case series.Samples: A total of 1073 eyes of 810 patients consecutively operated from January 2006 to July 2008 were evaluated.Methods: Two groups were created according to the type of ring implanted: Group 1 – patients implanted with the 160° of arc ring – and Group 2 – patients implanted with the 210° of arc ring.Main Outcome Measures: Uncorrected visual acuity, best‐corrected visual acuity, keratometry, asphericity and pachymetry at the thinnest point of the cornea. All patients were evaluated using a corneal tomography (Pentacam, Oculus, Inc., Lynnwood, WA, USA).Results: For Group 1 patients, uncorrected visual acuity increased to 20/80, best‐corrected visual acuity increased to 20/40, asphericity decreased to −0.35, spherical equivalent decreased to −2.26 D and keratometry decreased to 45.72 D (P < 0.001 for each compared with preoperative values). For Group 2 patients, uncorrected visual acuity increased to 20/130, best‐corrected visual acuity increased to 20/60, asphericity decreased to −0.56, spherical equivalent decreased to −4.14 D and keratometry decreased to 48.10 D (P < 0.001 for each compared with preoperative values). The 210° intrastromal corneal ring segments reduced keratometry and asphericity more than the 160° intrastromal corneal ring segments did. The complication rate was 3.82%.Conclusions: Ferrara intrastromal corneal ring segments implantation is safe and effective and has a low complication rate. It can effectively reduce the corneal steepening and improve uncorrected visual acuity and best‐corrected visual acuity in patients with keratoconus.