Super‐global distortion correction for a rotational C‐arm x‐ray image intensifier
- 7 September 1999
- journal article
- Published by Wiley in Medical Physics
- Vol. 26 (9) , 1802-1810
Abstract
Image intensifier (II) distortion changes as a function of C-arm rotation angle because of changes in the orientation of the II with the earth’s or other stray magnetic fields. For cone-beam computed tomography(CT), distortion correction for all angles is essential. The new super-global distortion correction consists of a model to continuously correct II distortion not only at each location in the image but for every rotational angle of the C arm. Calibration bead images were acquired with a standard C arm in 9 in. II mode. The super-global (SG) model is obtained from the single-plane global correction of the selected calibrationimages with given sampling angle interval. The fifth-order single-plane global corrections yielded a residual rms error of 0.20 pixels, while the SG model yielded a rms error of 0.21 pixels, a negligibly small difference. We evaluated the accuracy dependence of the SG model on various factors, such as the single-plane global fitting order, SG order, and angular sampling interval. We found that a good SG model can be obtained using a sixth-order SG polynomial fit based on the fifth-order single-plane global correction, and that a 10° sampling interval was sufficient. Thus, the SG model saves processing resources and storage space. The residual errors from the mechanical errors of the x-ray system were also investigated, and found comparable with the SG residual error. Additionally, a single-plane global correction was done in the cylindrical coordinate system, and physical information about pincushion distortion and S distortion were observed and analyzed; however, this method is not recommended due to a lack of calculational efficiency. In conclusion, the SG model provides an accurate, fast, and simple correction for rotational C-arm images, which may be used for cone-beam CT.Keywords
This publication has 6 references indexed in Scilit:
- Accurate and efficient image intensifier distortion correction algorithm for volume tomographic angiographyOptical Engineering, 1998
- The accuracy and reproducibility of a global method to correct for geometric image distortion in the x‐ray imaging chainMedical Physics, 1997
- Three‐dimensional computed tomographic reconstruction using a C‐arm mounted XRII: Correction of image intensifier distortionMedical Physics, 1997
- Accurate and efficient image-intensifier distortion-correction algorithm and its application in volume tomographic angiography1997
- Correction of image intensifier distortion for three-dimensional x-ray angiography1995
- Accurate characterization of image intensifier distortionMedical Physics, 1991