Tunneled dialysis catheter exchange through fibrin sheath crevice vs in situ catheter exchange for the treatment of catheter dysfunction
Authors:
- 9 January 2020
- journal article
- research article
- Published by Wiley in Therapeutic Apheresis and Dialysis
- Vol. 24 (6) , 695-702
Abstract
Our aim is to evaluate the safety and efficacy of tunneled dialysis catheter (TDC) exchange through fibrin sheath crevice vs in situ catheter exchange in hemodialysis patients with fibrin‐sheath‐related catheter dysfunction. Patients with fibrin‐sheath‐related catheter dysfunction who underwent TDC exchange in our center between 2012 January and 2017 December were retrospectively screened. The included patients were divided into the sheath‐crevice group (catheter was exchanged through fibrin sheath crevice) and the in situ group (catheter was exchanged in situ). The blood volume, Kt/V values, and complications were assessed as outcomes. Of the 44 included patients, 25 underwent in situ catheter exchange and 19 underwent catheter exchange through the fibrin sheath crevice. The stabilized maximal blood flow during the first hemodialysis after the catheter replacement reached 250 mL/min in all of the included patients. After 3 months, the stabilized maximal blood flow of the in situ group and the sheath‐crevice group were 245.3 ± 9.0 and 244.8 ± 10.05 mL/min (P = .963), respectively. However, after 6 months, the stabilized maximal blood flow during hemodialysis (P = .048) and the Kt/V value (P < .001) of the patients in the sheath‐crevice group were significantly higher than the in situ group. No severe complication related to the catheter exchange surgery was observed in either group. For patients with TDC dysfunction caused by fibrin sheath, catheter exchange through the fibrin sheath crevice most likely is a safe and effective alternative strategy for in situ catheter exchange.Keywords
This publication has 16 references indexed in Scilit:
- Balloon Angioplasty for Disruption of Tunneled Dialysis Catheter Fibrin SheathThe Journal of Vascular Access, 2011
- Catheter Management in Hemodialysis PatientsClinical Journal of the American Society of Nephrology, 2011
- Association Between Disruption of Fibrin Sheaths Using Percutaneous Transluminal Angioplasty Balloons and Late Onset of Central Venous StenosisCardioVascular and Interventional Radiology, 2010
- Clinical Practice Guidelines for Vascular AccessAmerican Journal of Kidney Diseases, 2006
- Restoration of Patency in Failing Tunneled Hemodialysis Catheters: A Comparison of Catheter Exchange, Exchange and Balloon Disruption of the Fibrin Sheath, and Femoral StrippingJournal of Vascular and Interventional Radiology, 2006
- Survival and Complications of Indwelling Venous Catheters for Permanent Use in Hemodialysis PatientsArtificial Organs, 2005
- Vascular access results from the Dialysis Outcomes and Practice Patterns Study (DOPPS): Performance against Kidney Disease Outcomes Quality Initiative (K/DOQI) Clinical Practice GuidelinesAmerican Journal of Kidney Diseases, 2004
- Percutaneous Fibrin Sheath Stripping versus Transcatheter Urokinase Infusion for Malfunctioning Wellpositioned Tunneled Central Venous Dialysis Catheters: A Prospective, Randomized TrialJournal of Vascular and Interventional Radiology, 2000
- Silastic cuffed catheters for hemodialysis vascular access: Thrombolytic and mechanical correction of malfunctionAmerican Journal of Kidney Diseases, 1996
- Utilization of inpatient and outpatient resources for the management of hemodialysis access complicationsAmerican Journal of Kidney Diseases, 1996