Ordered Mesoporous Carbon/Poly (2‐Hydroxyethyl Methacrylate/Ag Nanoparticle Composite Modified Glassy Carbon Electrode; an Amplified Sensor for Simultaneous Determination of Acetaminophen and Domperidone
- 14 August 2018
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 30 (10) , 2454-2461
Abstract
In this study, we describe a modification of a glassy carbon electrode with an ordered mesoporous carbon (OMC)/poly (2‐hydroxyethyl methacrylate) (PHEMA)/Ag nanoparticle composite (GCE/AgNPs‐PHEMA‐CMK‐1) done for the first time and the application of a proposed sensor for the simultaneous determination of acetaminophen (AC) and domperidone (DO). The transmission electron microscopy (TEM), fourier‐transform infrared spectroscopy (FT‐IR), electrochemical impedance spectroscopy (EIS), UV‐vis spectroscopy, and X‐ray powder diffraction (XRD) methods were used for the analysis of the synthesized nanocomposite. The GCE/AgNPs‐PHEMA‐CMK‐1 showed good catalytic activity for the electro‐oxidation of acetaminophen and domperidone in the buffer solution. The pH investigation showed that acetaminophen and domperidone electro‐oxidation is relative to the pH value of the solution. The maximum oxidation process occurred at pH=7.0 and pH=8.0 for acetaminophen and domperidone, respectively, on the surface of the GCE/AgNPs‐PHEMA‐CMK‐1. The GCE/AgNPs‐PHEMA‐CMK‐1 showed a linear range between 0.015–7.5 μM and 0.03–10.8 μM for acetaminophen and domperidone, respectively. The GCE/AgNPs‐PHEMA‐CMK‐1 showed detection limits of 0.005 and 0.01 μM for acetaminophen and domperidone, respectively, by the differential pulse voltammetry (DPV) method. Finally, the GCE/AgNPs‐PHEMA‐CMK‐1 was suggested as a highly powerful tool for the analysis of acetaminophen and domperidone in real samples.Keywords
Funding Information
- Kharazmi University
This publication has 34 references indexed in Scilit:
- Ordered mesoporous carbon for electrochemical sensing: A reviewAnalytica Chimica Acta, 2012
- The nanocomposite of PtPd nanoparticles/onion-like mesoporous carbon vesicle for nonenzymatic amperometric sensing of glucoseSensors and Actuators B: Chemical, 2011
- Synthesis and characterization of poly(4-vinylpyridine)/MCM-48 catalyst for one-pot synthesis of substituted 4H-chromenesCatalysis Communications, 2011
- Acetaminophen determination in low-dose pharmaceutical syrup by NIR spectroscopyJournal of Pharmaceutical and Biomedical Analysis, 2010
- Novel poly(3-methylthiophene)/Pd, Pt nanoparticle sensor: Synthesis, characterization and its application to the simultaneous analysis of dopamine and ascorbic acid in biological fluidsSensors and Actuators B: Chemical, 2010
- Gradient HPLC analysis of raloxifene hydrochloride and its application to drug quality controlActa Pharmaceutica, 2008
- Electrochemical determination of acetaminophen using a glassy carbon electrode coated with a single-wall carbon nanotube-dicetyl phosphate filmMicrochimica Acta, 2006
- HPLC analysis of raloxifene hydrochloride and its application to drug quality control studiesPharmacological Research, 2005
- Domperidone Plus Paracetamol in The Treatment of MigraineCephalalgia, 1993
- Diode array spectroscopy in pharmaceutical analysis: Determination of acetaminophen/ codeine phosphate tabletsJournal of Pharmaceutical and Biomedical Analysis, 1989