A finite element infant eye model to investigate retinal forces in shaken baby syndrome
- 4 December 2008
- journal article
- pediatrics
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 247 (4) , 561-571
Abstract
Background Shaken baby syndrome (SBS) is a form of abuse in which an infant, typically 6 months or less, is held and submitted to repeated acceleration-deceleration forces. One of the indicators of abuse is bilateral retinal hemorrhaging. A computational model of an infant eye, using the finite element method, is built in order to assess forces at the posterior retina for a shaking and an impact motions. Method The eye model is based on histological studies, diagrams, and materials from previous literature. Motions are applied to the model to simulate a four-cycle shaking motion in 1 second with maximum extension/flexion of the neck. The retinal forces of the shaking motion, at the posterior eye, are compared to an impact pulse (60G) simulating a fall for a total duration of 100 ms. Results The shaking motion, for the first cycle, shows retinal force means at the posterior eye to be around 0.08 N sustained from the time range of 50 to 200 ms, into the shake, with a peak in excess of 0.2 N. The impulse, area under the curve, is 15 N-ms for 250 msec for the first cycle. The impact simulation reveals a mean retinal force around 0.025 N for a time range of 0 to 26 ms, with a peak force around 0.11 N. Moreover, the impulse for the impact simulation is 13 times lower than the shaking motion. Conclusion The results suggest that shaking alone may be enough to cause retinal hemorrhaging, as there are more sustained and higher forces in the posterior retina, compared to an impact due to a fall. This is in part due to the optic nerve causing more localized stresses in a shaking motion than an impact.Keywords
This publication has 42 references indexed in Scilit:
- Finite Element Modeling of Optic Nerve Head BiomechanicsInvestigative Ophthalmology & Visual Science, 2004
- Behaviour of isoparametric quadrilateral family of Lagrangian fluid finite elementsInternational Journal for Numerical Methods in Engineering, 2002
- Biomechanical 3-D finite element modeling of the human breast using MRI dataIEEE Transactions on Medical Imaging, 2001
- Macromolecular structure of the corpus vitreusProgress in Polymer Science, 1998
- Disappearing Subdural Hematomas in ChildrenPediatric Neurosurgery, 1996
- Mathematical modelling of the elastic properties of retina: A determination of Young's modulusEye, 1992
- A proposed tolerance criterion for diffuse axonal injury in manJournal of Biomechanics, 1992
- The shaken baby syndromeJournal of Neurosurgery, 1987
- The Mechanical Properties of the Vitreous of Pig and Human Donor EyesOphthalmic Research, 1982
- The Elasticity of Sclera and Choroid of the Human Eye, and Its Implications on Scleral Rigidity and AccommodationJournal of Biomechanical Engineering, 1977