SBSebastian Bawab

Sebastian Bawab

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sebastian Bawab has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Load sharing assessment of osseoligamentous structures within a thoracic spine segment during surgical release

    by Michael Polanco, James Bennett, Austin Tapp, Michel Audette, Stacie Ringleb, Sebastian Bawab

    Spinal surgical procedures often require release of intervertebral discs and ligaments to optimally achieve postural correction on a patient-specific basis. In this paper, a T7-T8 Finite Element (FE) model is utilized to examine internal load sharing during resection steps performed in a Ponte osteotomy. The FE model was rotated bidirectionally along three anatomical planes using an externally applied moment. In each step, the Ranges of Motion (RoM), Instantaneous Centers of Rotation (ICR), and forces from ligaments, discs, facet, and costovertebral joints were calculated. The product of each component’s force and the distance between the ICR and their position were used to calculate percent load sharing at the maximum moment magnitude. Removal of the facet joints accounts for overall significant increases in load sharing to the intervertebral disc, with maximum values reported in extension by approximately 18 percent and axial rotation by 16 percent. This study highlights key spine components whose kinematic influence may be considered to achieve desired surgical outcomes.

  • A comparison of intervertebral ligament properties utilized in a thoracic spine functional unit through kinematic evaluation

    by Michael Polanco, Stacie Ringleb, Michel Audette, Rumit Kakar, Sebastian Bawab

    Ligament properties in the literature are variable, yet scarce, but needed to calibrate computational models for spine clinical research applications. A comparison of ligament stiffness properties and their effect on the kinematic behavior of a thoracic functional spinal unit (FSU) is examined in this paper. Six unique ligament property sets were utilized within a volumetric T7–T8 finite element (FE) model developed using computer-aided design (CAD) spinal geometry. A 7.5 Nm moment was applied along three anatomical planes both with and without costovertebral (CV) joints present. Range of Motion (RoM) was assessed for each property set and compared to published experimental data. Intact and serial ligament removal procedures were implemented in accordance with experimental protocol. The variance in both kinematic behavior and comparability with experimental data among property sets emphasizes the role nonlinear characterization plays in determining proper kinematic behavior in spinal FE models. Additionally, a decrease in RoM variation among property sets was exhibited when the model setup incorporated the CV joint. With proper assessment of the source and size of each ligament, the material properties considered here could be expanded and justified for implementation into thoracic spine clinical studies.


  • Open Access

    Computational Assessment of Neural Probe and Brain Tissue Interface under Transient Motion

    by Michael Polanco, Sebastian Bawab, Hargsoon Yoon

    The functional longevity of a neural probe is dependent upon its ability to minimize injury risk during the insertion and recording period in vivo, which could be related to motion-related strain between the probe and surrounding tissue. A series of finite element analyses was conducted to study the extent of the strain induced within the brain in an area around a neural probe. This study focuses on the transient behavior of neural probe and brain tissue interface with a viscoelastic model. Different stages of the interface from initial insertion of neural probe to full bonding of the probe by astro-glial sheath formation are simulated utilizing analytical tools to investigate the effects of relative motion between the neural probe and the brain while friction coefficients and kinematic frequencies are varied. The analyses can provide an in-depth look at the quantitative benefits behind using soft materials for neural probes.


  • Predictive Neuromuscular Fatigue of the Lower Extremity Utilizing Computer Modeling

    by Michael A. Samaan, Joshua T. Weinhandl, Steven A. Hans, Sebastian Y. Bawab, Stacie I. Ringleb

    This paper studies the modeling of lower extremity muscle forces and their correlation to neuromuscular fatigue. Two analytical fatigue models were combined with a musculoskeletal model to estimate the effects of hamstrings fatigue on lower extremity muscle forces during a side step cut. One of the fatigue models (Tang) used subject-specific knee flexor muscle fatigue and recovery data while the second model (Xia) used previously established fatigue and recovery parameters. Both fatigue models were able to predict hamstrings fatigue within 20% of the experimental data, with the semimembranosus and semitendinosus muscles demonstrating the largest (11%) and smallest (1%) differences, respectively. In addition, various hamstrings fatigue levels (10–90%) on lower extremity muscle force production were assessed using one of the analytical fatigue models. As hamstrings fatigue levels increased, the quadriceps muscle forces decreased by 21% (p < 0.01), while gastrocnemius muscle forces increased by 36% (p < 0.01). The results of this study validate the use of two analytical fatigue models in determining the effects of neuromuscular fatigue during a side step cut, and therefore, this model can be used to assess fatigue effects on risk of lower extremity injury during athletic maneuvers. Understanding the effects of fatigue on muscle force production may provide insight on muscle group compensations that may lead to altered lower extremity motion patterns as seen in noncontact anterior cruciate ligament (ACL) injuries.


  • A finite element infant eye model to investigate retinal forces in shaken baby syndrome

    by Steven Alex Hans, Sebastian Y. Bawab, Michael L. Woodhouse

    Background Shaken baby syndrome (SBS) is a form of abuse in which an infant, typically 6 months or less, is held and submitted to repeated acceleration-deceleration forces. One of the indicators of abuse is bilateral retinal hemorrhaging. A computational model of an infant eye, using the finite element method, is built in order to assess forces at the posterior retina for a shaking and an impact motions. Method The eye model is based on histological studies, diagrams, and materials from previous literature. Motions are applied to the model to simulate a four-cycle shaking motion in 1 second with maximum extension/flexion of the neck. The retinal forces of the shaking motion, at the posterior eye, are compared to an impact pulse (60G) simulating a fall for a total duration of 100 ms. Results The shaking motion, for the first cycle, shows retinal force means at the posterior eye to be around 0.08 N sustained from the time range of 50 to 200 ms, into the shake, with a peak in excess of 0.2 N. The impulse, area under the curve, is 15 N-ms for 250 msec for the first cycle. The impact simulation reveals a mean retinal force around 0.025 N for a time range of 0 to 26 ms, with a peak force around 0.11 N. Moreover, the impulse for the impact simulation is 13 times lower than the shaking motion. Conclusion The results suggest that shaking alone may be enough to cause retinal hemorrhaging, as there are more sustained and higher forces in the posterior retina, compared to an impact due to a fall. This is in part due to the optic nerve causing more localized stresses in a shaking motion than an impact.