The validity of a novel radiological method for measuring femoral stem version on anteroposterior radiographs of the hip after total hip arthroplasty
Authors:
- 1 March 2015
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 97-B (3) , 306-311
Abstract
Femoral stem version has a major influence on impingement and early post-operative stability after total hip arthroplasty (THA). The main objective of this study was to evaluate the validity of a novel radiological method for measuring stem version. Anteroposterior (AP) radiographs and three-dimensional CT scans were obtained for 115 patients (female/male 63/72, mean age 62.5 years (50 to 75)) who had undergone minimally invasive, cementless THA. Stem version was calculated from the AP hip radiograph by rotation-based change in the projected prosthetic neck–shaft (NSA*) angle using the mathematical formula ST = arcos [tan (NSA*) / tan (135)]. We used two independent observers who repeated the analysis after a six-week interval. Radiological measurements were compared with 3D-CT measurements by an independent, blinded external institute. We found a mean difference of 1.2° (sd 6.2) between radiological and 3D-CT measurements of stem version. The correlation between the mean radiological and 3D-CT stem torsion was r = 0.88 (p < 0.001). The intra- (intraclass correlation coefficient ≥ 0.94) and inter-observer agreement (mean concordance correlation coefficient = 0.87) for the radiological measurements were excellent. We found that femoral tilt was associated with the mean radiological measurement error (r = 0.22, p = 0.02). The projected neck–shaft angle is a reliable method for measuring stem version on AP radiographs of the hip after a THA. However, a highly standardised radiological technique is required for its precise measurement. Cite this article: Bone Joint J 2015; 97-B:306–11.Keywords
This publication has 23 references indexed in Scilit:
- The influence of hip rotation on femoral offset in plain radiographsActa Orthopaedica, 2014
- Is the acetabular cup orientation after total hip arthroplasty on a two dimension or three dimension model accurate?International Orthopaedics, 2014
- Radiological measurement of femoral stem version using a modified Budin methodThe Bone & Joint Journal, 2013
- The importance of adequate stem anteversion for rotational stability in cemented total hip replacementThe Bone & Joint Journal, 2013
- Minimally invasive computer-navigated total hip arthroplasty, following the concept of femur first and combined anteversion: design of a blinded randomized controlled trialBMC Musculoskeletal Disorders, 2011
- Guidelines for Implant Placement to Minimize Impingement During Activities of Daily Living After Total Hip ArthroplastyThe Journal of Arthroplasty, 2010
- Stem torsion in total hip replacementActa Orthopaedica, 2010
- The Effect of the Orientation of the Acetabular and Femoral Components on the Range of Motion of the Hip at Different Head-Neck Ratios*Journal of Bone and Joint Surgery, 2000
- Predictors of blood loss during total hip replacement surgeryArthritis & Rheumatism, 1995
- Evaluation of acetabular anteversion following total hip arthroplasty: necessity of proper centringBritish Journal of Radiology, 1975