Analysis of intraocular positions of posterior implantable collamer lens by full-scale ultrasound biomicroscopy
Authors:
Open Access
- 9 May 2018
- journal article
- research article
- Published by Springer Nature in BMC Ophthalmology
- Vol. 18 (1) , 1-11
Abstract
To analyze the positions of intraocular posterior Implantable Collamer Lens (ICL) and its possible relationship with vault. This cross-sectional study included 72 patients with high myopia (134 eyes) who were followed up after phakic intraocular lens implantation. The postoperative time ranged from 1 week to 7 years. We obtained the images of ICL by using Compact Touch STS UBM and observed the position of ICL in posterior chamber and ciliary sulcus. The horizontal lines vault was measured and recorded. There were various positions in the posterior chamber as observed by full-scale ultrasound biomicroscopy and the haptics were inserted at different positions. -Eight seven eyes (64.9%) that obtained ideal vault, 29 eyes (21.6%) had insufficient vaults and 18 eyes (13.4%) had excessive vault. The vault with various positions of haptics was in ideal range (250 μm–750 μm) almost in each group. Three eyes in this study with haptics on the top of ciliary sulcus obtained excessive vault (mean vault, 850.00 ± 70.71 μm) and one eye appeared one side haptics pushing forward the iris. Among five eyes (3.7%) with iridociliary body cysts, three eyes (60%) obtained ideal vault. One eye (0.7%) with ICL decentralization after implantation surgery had an ideal vault, but the patient had serious glare. Though ICL in the posterior chamber had different positions and the haptics in most cases were not in the ciliary sulcus, the postoperative vault was almost in the ideal range.Keywords
Funding Information
- The project from the Shanghai Shenkang Hospital Development Center (SHDC12016207)
- The project from the Health and Family Planning Committee of Pudong New District of Shanghai, China (PW2014D-1)
This publication has 22 references indexed in Scilit:
- Observing implantable collamer lens dislocation by panoramic ultrasound biomicroscopyEye, 2015
- Comparison of visual and refractive results of Toric Implantable Collamer Lens with bioptics for myopic astigmatismGraefe's Archive for Clinical and Experimental Ophthalmology, 2012
- Central vault after phakic intraocular lens implantation: Correlation with anterior chamber depth, white-to-white distance, spherical equivalent, and patient ageJournal of Cataract & Refractive Surgery, 2012
- Changes in Objective Vault and Effect on Vision Outcomes after Implantable Collamer Lens Implantation: 1-Year Follow-upEuropean Journal of Ophthalmology, 2011
- Comparison of the Toric Implantable Collamer Lens and Custom Ablation LASIK for Myopic AstigmatismJournal of Refractive Surgery, 2008
- Correlation between ciliary sulcus diameter measured by 35 MHz ultrasound biomicroscopy and other ocular measurementsJournal of Cataract & Refractive Surgery, 2008
- Ultrasound Biomicroscopy for Determining Visian Implantable Contact Lens Length in Phakic IOL ImplantationJournal of Refractive Surgery, 2007
- Toric Implantable Collamer Lens for Moderate to High Myopic AstigmatismOphthalmology, 2007
- Biomicroscopie ultrasonore des implants phaques de chambre postérieure : étude comparative des modèles ICL et PRLJournal Français d'Ophtalmologie, 2005
- Ultrasound biomicroscopy of ciliary body cystsAmerican Journal of Ophthalmology, 1999