Past and present work practices of European interventional cardiologists in the context of radiation protection of the eye lens—results of the EURALOC study
- 12 June 2018
- journal article
- research article
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 38 (3) , 934-950
Abstract
This paper investigates over five decades of work practices in interventional cardiology, with an emphasis on radiation protection. The analysis is based on data from more than 400 cardiologists from various European countries recruited for a EURALOC study and collected in the period from 2014 to 2016. Information on the types of procedures performed and their annual mean number, fluoroscopy time, access site choice, x-ray units and radiation protection means used was collected using an occupational questionnaire. Based on the specific European data, changes in each parameter have been analysed over decades, while country-specific data analysis has allowed us to determine the differences in local practices. In particular, based on the collected data, the typical workload of a European cardiologist working in a haemodynamic room and an electrophysiology room was specified for various types of procedures. The results showed that when working in a haemodynamic room, a transparent ceiling-suspended lead shield or lead glasses are necessary in order to remain below the recommended eye lens dose limit of 20 mSv. Moreover, the analysis revealed that new, more complex cardiac procedures such as chronic total occlusion, valvuloplasty and pulmonary vein isolation for atrial fibrillation ablation might contribute substantially to annual doses, although they are relatively rarely performed. The results revealed that considerable progress has been made in the use of radiation protection tools. While their use in electrophysiology procedures is not generic, the situation in haemodynamic procedures is rather encouraging, as ceiling-suspended shields are used in 90% of cases, while the combination of ceiling shield and lead glasses is noted in more than 40% of the procedures. However, we find that still 7% of haemodynamic procedures are performed without any radiation protection tools.Keywords
Funding Information
- OPERRA-2013 (60498)
This publication has 19 references indexed in Scilit:
- Radiation-Induced Lens Opacities among Interventional Cardiologists: Retrospective Assessment of Cumulative Eye Lens DosesRadiation Research, 2018
- Eye Lens Opacities Among Physicians Occupationally Exposed to Ionizing RadiationAnnals of Occupational Hygiene, 2015
- Interventional cardiologists and risk of radiation-induced cataract: Results of a French multicenter observational studyInternational Journal of Cardiology, 2013
- Occupational exposure to low doses of ionizing radiation and cataract development: a systematic literature review and perspectives on future studiesRadiation and Environmental Biophysics, 2013
- Staff eye lens and extremity exposure in interventional cardiology: Results of the ORAMED projectRadiation Measurements, 2011
- Lens opacities among physicians occupationally exposed to ionizing radiation – a pilot study in FinlandScandinavian Journal of Work, Environment & Health, 2011
- Risk for radiation‐induced cataract for staff in interventional cardiology: Is there reason for concern?Catheterization and Cardiovascular Interventions, 2010
- Radiation Cataract Risk in Interventional Cardiology PersonnelRadiation Research, 2010
- Risk of Cataract after Exposure to Low Doses of Ionizing Radiation: A 20-Year Prospective Cohort Study among US Radiologic TechnologistsAmerican Journal of Epidemiology, 2008
- A REANALYSIS OF ATOMIC-BOMB CATARACT DATA, 2000???2002: A THRESHOLD ANALYSISHealth Physics, 2006