Abstract
Purpose: To confirm ihMT's specificity to myelin, an ihMT presaturation module was combined with a Poon–Henkelman multi‐echo spin‐echo readout to separate the ihMT signal in myelin water from intra‐/extra‐cellular water. This study explored the relationship between two quantitative myelin imaging techniques and measured the ihMT signal of myelin water. Methods: Six rats were injured; three were sacrificed three weeks post‐injury, and three were sacrificed eight weeks post‐injury, and three healthy control rats were also sacrificed. The nine formalin‐fixed rat spinal cords were imaged using a Poon–Henkelman multi‐echo spin‐echo readout with an ihMT prepulse at different strengths of filtering at 7T. Results: The proposed model was able to characterize the ihMT decay signal in myelin water and intra‐/extra‐cellular water pool. From this proposed four‐pool model with dipolar order reservoirs, we see a drop in the fit parameter in the fasciculus gracilis white matter region of the three‐week post‐injury cord. and (non‐myelin) were estimated to be approx. 8 and 1.5 ms, respectively. Conclusion: The drop in in the three‐week post‐injury cords suggests that could potentially distinguish between functional myelin and myelin debris; however, more studies are needed to confirm this.
Funding Information
  • Natural Sciences and Engineering Research Council of Canada (RGPIN‐2019‐04505)

This publication has 34 references indexed in Scilit: