Interpretation of inhomogeneous magnetization transfer in myelin water using a four‐pool model with dipolar reservoirs
Open Access
- 18 February 2025
- journal article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (1) , 278-292
Abstract
Purpose: To confirm ihMT's specificity to myelin, an ihMT presaturation module was combined with a Poon–Henkelman multi‐echo spin‐echo readout to separate the ihMT signal in myelin water from intra‐/extra‐cellular water. This study explored the relationship between two quantitative myelin imaging techniques and measured the ihMT signal of myelin water. Methods: Six rats were injured; three were sacrificed three weeks post‐injury, and three were sacrificed eight weeks post‐injury, and three healthy control rats were also sacrificed. The nine formalin‐fixed rat spinal cords were imaged using a Poon–Henkelman multi‐echo spin‐echo readout with an ihMT prepulse at different strengths of filtering at 7T. Results: The proposed model was able to characterize the ihMT decay signal in myelin water and intra‐/extra‐cellular water pool. From this proposed four‐pool model with dipolar order reservoirs, we see a drop in the fit parameter in the fasciculus gracilis white matter region of the three‐week post‐injury cord. and (non‐myelin) were estimated to be approx. 8 and 1.5 ms, respectively. Conclusion: The drop in in the three‐week post‐injury cords suggests that could potentially distinguish between functional myelin and myelin debris; however, more studies are needed to confirm this.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada (RGPIN‐2019‐04505)
This publication has 34 references indexed in Scilit:
- High‐resolution myelin water measurements in rat spinal cordMagnetic Resonance in Medicine, 2008
- Modeling pulsed magnetization transferMagnetic Resonance in Medicine, 2007
- Quantitative magnetization transfer imaging via selective inversion recovery with short repetition timesMagnetic Resonance in Medicine, 2007
- Characterization of the NMR behavior of white matter in bovine brainMagnetic Resonance in Medicine, 2005
- Diffusion tensor imaging of in vivo and excised rat spinal cord at 7 T with an icosahedral encoding schemeMagnetic Resonance in Medicine, 2004
- Pulsed Z‐spectroscopic imaging of cross‐relaxation parameters in tissues for human MRI: Theory and clinical applicationsMagnetic Resonance in Medicine, 2002
- Characterizing white matter with magnetization transfer andT2Magnetic Resonance in Medicine, 1999
- Quantitative imaging of magnetization transfer using multiple selective pulsesMagnetic Resonance in Medicine, 1999
- In vivo visualization of myelin water in brain by magnetic resonanceMagnetic Resonance in Medicine, 1994
- Practical T2 quantitation for clinical applicationsJournal of Magnetic Resonance Imaging, 1992