Michelle H. Lam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Michelle H. Lam has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Alan P. Manning
Physics and Astronomy University of British Columbia British Columbia Vancouver Canada
1 shared publication - Andrew Yung
MRI Research Centre, University of British Columbia, Vancouver, Canada
1 shared publication Jie Liu
International Collaboration on Repair Discoveries University of British Columbia British Columbia Vancouver Canada
1 shared publication- Masha Novoselova
Wolfson Brain Imaging Centre University of Cambridge Cambridge UK
1 shared publication - Piotr Kozlowski
Physics & Astronomy University of British Columbia Vancouver Canada
1 shared publication - Valentin H. Prevost
UBC MRI Research Centre University of British Columbia British Columbia Vancouver Canada
1 shared publication
Latest Publications
- Open Access
- 18 February 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (1) , 278-292
Interpretation of inhomogeneous magnetization transfer in myelin water using a four‐pool model with dipolar reservoirs
Purpose: To confirm ihMT's specificity to myelin, an ihMT presaturation module was combined with a Poon–Henkelman multi‐echo spin‐echo readout to separate the ihMT signal in myelin water from intra‐/extra‐cellular water. This study explored the relationship between two quantitative myelin imaging techniques and measured the ihMT signal of myelin water. Methods: Six rats were injured; three were sacrificed three weeks post‐injury, and three were sacrificed eight weeks post‐injury, and three healthy control rats were also sacrificed. The nine formalin‐fixed rat spinal cords were imaged using a Poon–Henkelman multi‐echo spin‐echo readout with an ihMT prepulse at different strengths of filtering at 7T. Results: The proposed model was able to characterize the ihMT decay signal in myelin water and intra‐/extra‐cellular water pool. From this proposed four‐pool model with dipolar order reservoirs, we see a drop in the fit parameter in the fasciculus gracilis white matter region of the three‐week post‐injury cord. and (non‐myelin) were estimated to be approx. 8 and 1.5 ms, respectively. Conclusion: The drop in in the three‐week post‐injury cords suggests that could potentially distinguish between functional myelin and myelin debris; however, more studies are needed to confirm this.
- 18 February 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (1) , 278-292
Open AccessInterpretation of inhomogeneous magnetization transfer in myelin water using a four‐pool model with dipolar reservoirs
Purpose: To confirm ihMT's specificity to myelin, an ihMT presaturation module was combined with a Poon–Henkelman multi‐echo spin‐echo readout to separate the ihMT signal in myelin water from intra‐/extra‐cellular water. This study explored the relationship between two quantitative myelin imaging techniques and measured the ihMT signal of myelin water. Methods: Six rats were injured; three were sacrificed three weeks post‐injury, and three were sacrificed eight weeks post‐injury, and three healthy control rats were also sacrificed. The nine formalin‐fixed rat spinal cords were imaged using a Poon–Henkelman multi‐echo spin‐echo readout with an ihMT prepulse at different strengths of filtering at 7T. Results: The proposed model was able to characterize the ihMT decay signal in myelin water and intra‐/extra‐cellular water pool. From this proposed four‐pool model with dipolar order reservoirs, we see a drop in the fit parameter in the fasciculus gracilis white matter region of the three‐week post‐injury cord. and (non‐myelin) were estimated to be approx. 8 and 1.5 ms, respectively. Conclusion: The drop in in the three‐week post‐injury cords suggests that could potentially distinguish between functional myelin and myelin debris; however, more studies are needed to confirm this.