Implant Material, Type of Fixation at the Shaft, and Position of Plate Modify Biomechanics of Distal Femur Plate Osteosynthesis
Authors:
- 1 August 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 31 (8) , e241-e246
Abstract
Objectives: To investigate whether (1) the type of fixation at the shaft (hybrid vs. locking), (2) the position of the plate (offset vs. contact) and (3) the implant material has a significant effect on (a) construct stiffness and (b) fatigue life in a distal femur extraarticular comminuted fracture model using the same design of distal femur periarticular locking plate. Methods: An extraarticular severely comminuted distal femoral fracture pattern (OTA/AO 33-A3) was simulated using artificial bone substitutes. Ten-hole distal lateral femur locking plates were used for fixation per the recommended surgical technique. At the distal metaphyseal fragment, all possible locking screws were placed. For the proximal diaphyseal fragment, different types of screws were used to create 4 different fixation constructs: (1) stainless steel hybrid (SSH), (2) stainless steel locked (SSL), (3) titanium locked (TiL), and (4) stainless steel locked with 5-mm offset at the diaphysis (SSLO). Six specimens of each construct configuration were tested. First, each specimen was nondestructively loaded axially to determine the stiffness. Then, each specimen was cyclically loaded with increasing load levels until failure. Results: Construct Stiffness: The fixation construct with a stainless steel plate and hybrid fixation (SSH) had the highest stiffness followed by the construct with a stainless steel plate and locking screws (SSL) and were not statistically different from each other. Offset placement (SSLO) and using a titanium implant (TiL) significantly reduced construct stiffness. Fatigue Failure: The stainless steel with hybrid fixation group (SSH) withstood the most number of cycles to failure and higher loads, followed by the stainless steel plate and locking screw group (SSL), stainless steel plate with locking screws and offset group (SSLO), and the titanium plate and locking screws group (TiL) consecutively. Offset placement (SSLO) as well as using a titanium implant (TiL) reduced cycles to failure. Conclusions: Using the same plate design, the study showed that implant material, screw type, and position of the plate affect the construct stiffness and fatigue life of the fixation construct. With this knowledge, the surgeon can decide the optimal construct based on a given fracture pattern, bone strength, and reduction quality.Keywords
This publication has 42 references indexed in Scilit:
- 2010 Mid-America Orthopaedic Association Physician in Training Award: Healing Complications Are Common After Locked Plating for Distal Femur FracturesClinical Orthopaedics and Related Research, 2011
- The Influence of Fracture Fixation Biomechanics on Fracture HealingOrthopedics, 2010
- Locked Plating of Distal Femur Fractures Leads to Inconsistent and Asymmetric Callus FormationJournal of Orthopaedic Trauma, 2010
- Biomechanical Comparison of Polyaxial-Type Locking Plates and a Fixed-Angle Locking Plate for Internal Fixation of Distal Femur FracturesJournal of Orthopaedic Trauma, 2009
- Distal Femoral Fixation: A Biomechanical Comparison of Trigen Retrograde Intramedullary (I.M.) Nail, Dynamic Condylar Screw (DCS), and Locking Compression Plate (LCP) Condylar PlateJournal of Trauma: Injury, Infection & Critical Care, 2009
- Biomechanical Considerations in Plate Osteosynthesis: The Effect of Plate-to-Bone Compression With and Without Angular Screw StabilityJournal of Orthopaedic Trauma, 2007
- Biomechanical Analysis of Distal Femur Fracture Fixation: Fixed-Angle Screw-Plate Construct Versus Condylar Blade PlateJournal of Orthopaedic Trauma, 2007
- Biomechanical Evaluation of the Less Invasive Stabilization System and the 95-degree Angled Blade Plate for the Internal Fixation of Distal Femur Fractures in Human Cadaveric Bones with High Bone Mineral Density2006
- Shear movement at the fracture site delays healing in a diaphyseal fracture modelJournal of Orthopaedic Research, 2003
- Mechanics of Retrograde Nail Versus Plate Fixation for Supracondylar Femur FracturesJournal of Orthopaedic Trauma, 1995