Force level of small diameter nickel-titanium orthodontic wires ligated with different methods
Authors:
- Rodrigo Hitoshi HigaRHRodrigo Hitoshi Higa
- José Fernando Castanha HenriquesJHJosé Fernando Castanha Henriques
- Guilherme JansonGJGuilherme Janson
- Murilo MatiasMMMurilo Matias
- Karina Maria Salvatore de FreitasKFKarina Maria Salvatore de Freitas
- Fernanda Pinelli HenriquesFHFernanda Pinelli Henriques
- Manoela Fávaro FrancisconiMFManoela Fávaro Francisconi
Open Access
- 1 August 2017
- journal article
- research article
- Published by Springer Nature in Progress in Orthodontics
- Vol. 18 (1) , 21
Abstract
The aim of this study was to compare the deflection force in conventional and thermally activated nickel-titanium (NiTi) wires in passive (Damon Q) and active (Bioquick) self-ligating brackets (SLB) and in conventional brackets (CB) tied by two different methods: elastomeric ligature (EL) and metal ligature (ML). Two wire diameters (0.014 and 0.016 in.) and 10 specimens per group were used. The specimens were assembled in a clinical simulation device and tested in an Instron Universal Testing Machine, with a load cell of 10 N. For the testing procedures, the acrylic block representative of the right maxillary central incisor was palatally moved, with readings of the force at 0.5, 1, 2, and 3 mm, at a constant speed of 2 mm/min and temperature of 36.5 °C. The conventional NiTi released higher forces than the thermally activated NiTi archwires in large deflections. In general, the SLB showed lower forces, while the ML had higher forces, with both showing a similar force release behavior, constantly decreasing as the deflection decreased. The EL showed an irregular behavior. The active SLB showed smaller forces than passive, in large deflections. The SLB and the ML exhibit standard force patterns during unloading, while the elastomeric ligatures exhibit a randomly distributed force release behavior.Keywords
Funding Information
- Fundação de Amparo à Pesquisa do Estado de São Paulo (2013/10378-0)
This publication has 38 references indexed in Scilit:
- Load deflection characteristics and force level of nickel titanium initial archwiresThe Angle Orthodontist, 2012
- Load-deflection characteristics of superelastic and thermal nickel-titanium wiresEuropean Journal of Orthodontics, 2011
- Force Decay of Elastomeric Ligatures: Influence onUnloading Force Compared to Self-LigationThe Angle Orthodontist, 2009
- Comparison of frictional forces during the initial leveling stage in various combinations of self-ligating brackets and archwires with a custom-designed typodont systemAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2008
- Effect of long-term repeated deflections on fatigue of preloaded superelastic nickel-titanium archwiresAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2008
- Factors affecting friction in the pre-adjusted applianceEuropean Journal of Orthodontics, 2004
- Evaluation of friction of stainless steel and esthetic self-ligating brackets in various bracket-archwire combinationsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2003
- Interactive edgewise mechanisms: Form and function comparison with conventional edgewise bracketsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1997
- Force decay and deformation of orthodontic elastomeric ligaturesAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1997
- The super-elastic property of the Japanese NiTi alloy wire for use in orthodonticsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1986