Manoela Fávaro Francisconi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Manoela Fávaro Francisconi has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Fernanda Pinelli Henriques
Department of Orthodontics, Bauru Dental School, University of São Paulo, Alameda Octávio Pinheiro Brisolla 9-75, Bauru, SP, 17012-901, Brazil
1 shared publication - Guilherme Janson
Universidade de São Paulo, Brazil
1 shared publication - José Fernando Castanha Henriques
Department of Orthodontics, Bauru Dental School, University of São Paulo, Bauru, Brazil
1 shared publication - Karina Maria Salvatore Freitas
Department of Orthodontics, Ingá University Center UNINGÁ, Maringá, Brazil
1 shared publication - Murilo Matias
Department of Orthodontics, Guarulhos University, Guarulhos 07023-070, SP, Brazil
1 shared publication - Rodrigo Hitoshi Higa
Department of Orthodontics, Bauru Dental School, University of São Paulo, Alameda Octávio Pinheiro Brisolla 9-75, Bauru, SP, 17012-901, Brazil.
1 shared publication
Latest Publications
- Open Access
- 1 August 2017
- Published by Springer Nature in Progress in Orthodontics
- Vol. 18 (1) , 21
Force level of small diameter nickel-titanium orthodontic wires ligated with different methods
The aim of this study was to compare the deflection force in conventional and thermally activated nickel-titanium (NiTi) wires in passive (Damon Q) and active (Bioquick) self-ligating brackets (SLB) and in conventional brackets (CB) tied by two different methods: elastomeric ligature (EL) and metal ligature (ML). Two wire diameters (0.014 and 0.016 in.) and 10 specimens per group were used. The specimens were assembled in a clinical simulation device and tested in an Instron Universal Testing Machine, with a load cell of 10 N. For the testing procedures, the acrylic block representative of the right maxillary central incisor was palatally moved, with readings of the force at 0.5, 1, 2, and 3 mm, at a constant speed of 2 mm/min and temperature of 36.5 °C. The conventional NiTi released higher forces than the thermally activated NiTi archwires in large deflections. In general, the SLB showed lower forces, while the ML had higher forces, with both showing a similar force release behavior, constantly decreasing as the deflection decreased. The EL showed an irregular behavior. The active SLB showed smaller forces than passive, in large deflections. The SLB and the ML exhibit standard force patterns during unloading, while the elastomeric ligatures exhibit a randomly distributed force release behavior.
- 1 August 2017
- Published by Springer Nature in Progress in Orthodontics
- Vol. 18 (1) , 21
Open AccessForce level of small diameter nickel-titanium orthodontic wires ligated with different methods
The aim of this study was to compare the deflection force in conventional and thermally activated nickel-titanium (NiTi) wires in passive (Damon Q) and active (Bioquick) self-ligating brackets (SLB) and in conventional brackets (CB) tied by two different methods: elastomeric ligature (EL) and metal ligature (ML). Two wire diameters (0.014 and 0.016 in.) and 10 specimens per group were used. The specimens were assembled in a clinical simulation device and tested in an Instron Universal Testing Machine, with a load cell of 10 N. For the testing procedures, the acrylic block representative of the right maxillary central incisor was palatally moved, with readings of the force at 0.5, 1, 2, and 3 mm, at a constant speed of 2 mm/min and temperature of 36.5 °C. The conventional NiTi released higher forces than the thermally activated NiTi archwires in large deflections. In general, the SLB showed lower forces, while the ML had higher forces, with both showing a similar force release behavior, constantly decreasing as the deflection decreased. The EL showed an irregular behavior. The active SLB showed smaller forces than passive, in large deflections. The SLB and the ML exhibit standard force patterns during unloading, while the elastomeric ligatures exhibit a randomly distributed force release behavior.