Review of Experimental Modelling in Vascular Access for Hemodialysis
- 31 May 2017
- journal article
- review article
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 8 (3) , 330-341
Abstract
This paper reviews applications of experimental modelling in vascular access for hemodialysis. Different techniques that are used in in-vitro experiments are bulk pressure and flow rate measurements, Laser Doppler Velocimetry and Vector Doppler Ultrasound point velocity measurements, and whole-field measurements such as Particle Image Velocimetry, Ultrasound Imaging Velocimetry, Colour Doppler Ultrasound, and Planar Laser Induced Fluorescence. Of these methods, the ultrasound techniques can also be used in-vivo, to provide realistic boundary conditions to in-vitro experiments or numerical simulations. In the reviewed work, experimental modelling is mainly used to support computational models, but also in some cases as a tool on its own. It is concluded that, to further advance the utility of computational modelling in vascular access research, a rigorous verification and validation procedure should be adopted. Experimental modelling can play an important role in both in-vitro validation, and the quantification of the accuracy, uncertainty, and reproducibility of in-vivo measurement methods.Keywords
Funding Information
- Seventh Framework Programme (324487)
This publication has 31 references indexed in Scilit:
- Ultrasound imaging velocimetry: Toward reliable wall shear stress measurementsEuropean Journal of Mechanics - B/Fluids, 2012
- Experimental validation of a pulse wave propagation model for predicting hemodynamics after vascular access surgeryJournal of Biomechanics, 2012
- A pulse wave propagation model to support decision-making in vascular access planning in the clinicMedical Engineering & Physics, 2011
- Experimental Study of a New Method for Early Detection of Vascular Access Stenoses: Pulse Pressure Analysis at Hemodialysis NeedleArtificial Organs, 2010
- Numerical and experimental study of blood flow through a patient-specific arteriovenous fistula used for hemodialysisMedical Engineering & Physics, 2009
- Particle Image Velocimetry–Validated, Computational Fluid Dynamics–Based Design to Reduce Shear Stress and Residence Time in Central Venous Hemodialysis CathetersASAIO Journal, 2007
- Why don't fistulas mature?Kidney International, 2006
- Hemodynamics in a compliant hydraulic in vitro model of straight versus tapered PTFE arteriovenous graftJournal of Surgical Research, 2004
- Verification and validation in computational fluid dynamicsProgress in Aerospace Sciences, 2002
- XXIX. An experimental investigation of the circumstances which determine whether the motion of water shall be direct or sinuous, and of the law of resistance in parallel channelsPhilosophical Transactions of the Royal Society of London, 1883