Sita Drost
Sita Drost has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Christian Poelma
Delft University of Technology
3 shared publications Cornelis J. Drost
Transonic Systems Inc., Ithaca, USA
2 shared publications- David Newport
School of Engineering, Bernal Institute, University of Limerick, Limerick, Ireland
2 shared publications J Westerweel
Mechanical, Maritime and Materials Engineering, Delft University of Technology, Leeghwaterstraat 21, 2628 CA Delft, The Netherlands
2 shared publicationsA Gurung
Mechanical, Maritime and Materials Engineering, Delft University of Technology, Leeghwaterstraat 21, 2628 CA Delft, The Netherlands
1 shared publication- Amedeo Chiribiri
Guy’s and St Thomas’ Hospital & School of Biomedical Engineering and Imaging Sciences, King’s College London Department of Cardiology Westminster Bridge Road, London SE1 7EH
1 shared publication
Latest Publications
- Open Access
- 3 January 2025
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 16 (2) , 171-189
Flow-Based Coronary Artery Bypass Graft Patency Metrics: Uncertainty Quantification Simulations to Guide Development
Purpose: Over time, transit time flow measurement (TTFM) has proven itself as a simple and effective tool for intra-operative evaluation of coronary artery bypass grafts (CABGs). However, metrics used to screen for possible technical error show considerable spread, preventing the definition of sharp cut-off values to distinguish between patent, questionable, and failed grafts. The simulation study presented in this paper aims to quantify this uncertainty for commonly used patency metrics, and to identify the most important physiological parameters influencing it. Methods: Uncertainty quantification was performed on a realistic multiscale numerical model of the coronary circulation, guided by Morris screening sensitivity analysis of a simpler, lumped-parameter model. Simulation results were qualitatively verified against results of a recent clinical study. Results: Correspondence with clinical study data is reasonable, especially considering that the model was not fitted in any way. Stenosis severity was confirmed to be an influential parameter. However, also cardiac period and graft diameter were observed to be important, particularly for mean flow rate and pulsatility index. Conclusion: Metrics quantifying the flow waveform’s diastolic dominance show the highest sensitivity to graft stenosis, and seem to be least affected by autoregulation. Among these, the novel diastolic resistance index shows the strongest sensitivity to stenosis severity. Significance: The approach used in this study is expected to benefit the development of improved patency metrics, by allowing medical engineers to include sensitivity and uncertainty in assessing, in-silico, the potential of novel metrics, thus enabling them to provide better guidance in the design of clinical studies.
- 3 January 2025
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 16 (2) , 171-189
Open AccessFlow-Based Coronary Artery Bypass Graft Patency Metrics: Uncertainty Quantification Simulations to Guide Development
Purpose: Over time, transit time flow measurement (TTFM) has proven itself as a simple and effective tool for intra-operative evaluation of coronary artery bypass grafts (CABGs). However, metrics used to screen for possible technical error show considerable spread, preventing the definition of sharp cut-off values to distinguish between patent, questionable, and failed grafts. The simulation study presented in this paper aims to quantify this uncertainty for commonly used patency metrics, and to identify the most important physiological parameters influencing it. Methods: Uncertainty quantification was performed on a realistic multiscale numerical model of the coronary circulation, guided by Morris screening sensitivity analysis of a simpler, lumped-parameter model. Simulation results were qualitatively verified against results of a recent clinical study. Results: Correspondence with clinical study data is reasonable, especially considering that the model was not fitted in any way. Stenosis severity was confirmed to be an influential parameter. However, also cardiac period and graft diameter were observed to be important, particularly for mean flow rate and pulsatility index. Conclusion: Metrics quantifying the flow waveform’s diastolic dominance show the highest sensitivity to graft stenosis, and seem to be least affected by autoregulation. Among these, the novel diastolic resistance index shows the strongest sensitivity to stenosis severity. Significance: The approach used in this study is expected to benefit the development of improved patency metrics, by allowing medical engineers to include sensitivity and uncertainty in assessing, in-silico, the potential of novel metrics, thus enabling them to provide better guidance in the design of clinical studies.
- 19 March 2024
- Published by Elsevier in Seminars in Thoracic and Cardiovascular Surgery
- Vol. 36 (3) , 333-334
Sequential Coronary Artery Bypass Grafts: Flow-based Patency Assessment Criteria
- 19 March 2024
- Published by Elsevier in Seminars in Thoracic and Cardiovascular Surgery
- Vol. 36 (3) , 333-334
Sequential Coronary Artery Bypass Grafts: Flow-based Patency Assessment Criteria
- Open Access
- 19 May 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (5) , 2871-2884
Pixel‐wise assessment of cardiovascular magnetic resonance first‐pass perfusion using a cardiac phantom mimicking transmural myocardial perfusion gradients
Purpose: Cardiovascular magnetic resonance first‐pass perfusion for the pixel‐wise detection of coronary artery disease is rapidly becoming the clinical standard, yet no widely available method exists for its assessment and validation. This study introduces a novel phantom capable of generating spatially dependent flow values to enable assessment of new perfusion imaging methods at the pixel level.Methods: A synthetic multicapillary myocardial phantom mimicking transmural myocardial perfusion gradients was designed and manufactured with high‐precision 3D printing. The phantom was used in a stationary flow setup providing reference myocardial perfusion rates and was scanned on a 3T system. Repeated first‐pass perfusion MRI for physiological perfusion rates between 1 and 4 mL/g/min was performed using a clinical dual‐sequence technique. Fermi function‐constrained deconvolution was used to estimate pixel‐wise perfusion rate maps. Phase contrast (PC)‐MRI was used to obtain velocity measurements that were converted to perfusion rates for validation of reference values and cross‐method comparison. The accuracy of pixel‐wise maps was assessed against simulated reference maps.Results: PC‐MRI indicated excellent reproducibility in perfusion rate (coefficient of variation [CoV] 2.4‐3.5%) and correlation with reference values (R2 = 0.985) across the full physiological range. Similar results were found for first‐pass perfusion MRI (CoV 3.7‐6.2%, R2 = 0.987). Pixel‐wise maps indicated a transmural perfusion difference of 28.8‐33.7% for PC‐MRI and 23.8‐37.7% for first‐pass perfusion, matching the reference values (30.2‐31.4%).Conclusion: The unique transmural perfusion pattern in the phantom allows effective pixel‐wise assessment of first‐pass perfusion acquisition protocols and quantification algorithms before their introduction into routine clinical use.
- 19 May 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (5) , 2871-2884
Open AccessPixel‐wise assessment of cardiovascular magnetic resonance first‐pass perfusion using a cardiac phantom mimicking transmural myocardial perfusion gradients
Purpose: Cardiovascular magnetic resonance first‐pass perfusion for the pixel‐wise detection of coronary artery disease is rapidly becoming the clinical standard, yet no widely available method exists for its assessment and validation. This study introduces a novel phantom capable of generating spatially dependent flow values to enable assessment of new perfusion imaging methods at the pixel level.Methods: A synthetic multicapillary myocardial phantom mimicking transmural myocardial perfusion gradients was designed and manufactured with high‐precision 3D printing. The phantom was used in a stationary flow setup providing reference myocardial perfusion rates and was scanned on a 3T system. Repeated first‐pass perfusion MRI for physiological perfusion rates between 1 and 4 mL/g/min was performed using a clinical dual‐sequence technique. Fermi function‐constrained deconvolution was used to estimate pixel‐wise perfusion rate maps. Phase contrast (PC)‐MRI was used to obtain velocity measurements that were converted to perfusion rates for validation of reference values and cross‐method comparison. The accuracy of pixel‐wise maps was assessed against simulated reference maps.Results: PC‐MRI indicated excellent reproducibility in perfusion rate (coefficient of variation [CoV] 2.4‐3.5%) and correlation with reference values (R2 = 0.985) across the full physiological range. Similar results were found for first‐pass perfusion MRI (CoV 3.7‐6.2%, R2 = 0.987). Pixel‐wise maps indicated a transmural perfusion difference of 28.8‐33.7% for PC‐MRI and 23.8‐37.7% for first‐pass perfusion, matching the reference values (30.2‐31.4%).Conclusion: The unique transmural perfusion pattern in the phantom allows effective pixel‐wise assessment of first‐pass perfusion acquisition protocols and quantification algorithms before their introduction into routine clinical use.
- 3 November 2017
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 51 (1) , 67-71
Arduino control of a pulsatile flow rig
This note describes the design and testing of a programmable pulsatile flow pump using an Arduino micro-controller. The goal of this work is to build a compact and affordable system that can relatively easily be programmed to generate physiological waveforms. The system described here was designed to be used in an in-vitro set-up for vascular access hemodynamics research, and hence incorporates a gear pump that delivers a mean flow of 900 ml/min in a test flow loop, and a peak flow of 1106 ml/min. After a number of simple identification experiments to assess the dynamic behaviour of the system, a feed-forward control routine was implemented. The resulting system was shown to be able to produce the targeted representative waveform with less than 3.6% error. Finally, we outline how to further increase the accuracy of the system, and how to adapt it to specific user needs.
- 3 November 2017
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 51 (1) , 67-71
Arduino control of a pulsatile flow rig
This note describes the design and testing of a programmable pulsatile flow pump using an Arduino micro-controller. The goal of this work is to build a compact and affordable system that can relatively easily be programmed to generate physiological waveforms. The system described here was designed to be used in an in-vitro set-up for vascular access hemodynamics research, and hence incorporates a gear pump that delivers a mean flow of 900 ml/min in a test flow loop, and a peak flow of 1106 ml/min. After a number of simple identification experiments to assess the dynamic behaviour of the system, a feed-forward control routine was implemented. The resulting system was shown to be able to produce the targeted representative waveform with less than 3.6% error. Finally, we outline how to further increase the accuracy of the system, and how to adapt it to specific user needs.
- 31 May 2017
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 8 (3) , 330-341
Review of Experimental Modelling in Vascular Access for Hemodialysis
This paper reviews applications of experimental modelling in vascular access for hemodialysis. Different techniques that are used in in-vitro experiments are bulk pressure and flow rate measurements, Laser Doppler Velocimetry and Vector Doppler Ultrasound point velocity measurements, and whole-field measurements such as Particle Image Velocimetry, Ultrasound Imaging Velocimetry, Colour Doppler Ultrasound, and Planar Laser Induced Fluorescence. Of these methods, the ultrasound techniques can also be used in-vivo, to provide realistic boundary conditions to in-vitro experiments or numerical simulations. In the reviewed work, experimental modelling is mainly used to support computational models, but also in some cases as a tool on its own. It is concluded that, to further advance the utility of computational modelling in vascular access research, a rigorous verification and validation procedure should be adopted. Experimental modelling can play an important role in both in-vitro validation, and the quantification of the accuracy, uncertainty, and reproducibility of in-vivo measurement methods.
- 31 May 2017
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 8 (3) , 330-341
Review of Experimental Modelling in Vascular Access for Hemodialysis
This paper reviews applications of experimental modelling in vascular access for hemodialysis. Different techniques that are used in in-vitro experiments are bulk pressure and flow rate measurements, Laser Doppler Velocimetry and Vector Doppler Ultrasound point velocity measurements, and whole-field measurements such as Particle Image Velocimetry, Ultrasound Imaging Velocimetry, Colour Doppler Ultrasound, and Planar Laser Induced Fluorescence. Of these methods, the ultrasound techniques can also be used in-vivo, to provide realistic boundary conditions to in-vitro experiments or numerical simulations. In the reviewed work, experimental modelling is mainly used to support computational models, but also in some cases as a tool on its own. It is concluded that, to further advance the utility of computational modelling in vascular access research, a rigorous verification and validation procedure should be adopted. Experimental modelling can play an important role in both in-vitro validation, and the quantification of the accuracy, uncertainty, and reproducibility of in-vivo measurement methods.
- 11 August 2016
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 27 (9) , 094008
Ultrasound image velocimetry for rheological measurements
Ultrasound image velocimetry (UIV) allows for the non-intrusive measurement of a wide range of flows without the need for optical transparency. In this study, we used UIV to measure the local velocity field of a model drilling fluid that exhibits yield stress flow behavior. The radial velocity profile was used to determine the yield stress and the Herschel–Bulkley model flow index n and the consistency index k . Reference data were obtained using the conventional offline Couette rheometry. A comparison showed reasonable agreement between the two methods. The discrepancy in model parameters could be attributed to inherent differences between the methods, which cannot be captured by the three-parameter model used. Overall, with a whole flow field measurement technique such as UIV, we were able to quantify the complex rheology of a model drilling fluid. These preliminary results show that UIV can be used as a non-intrusive diagnostic for in situ , real-time measurement of complex opaque flow rheology.
- 11 August 2016
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 27 (9) , 094008
Ultrasound image velocimetry for rheological measurements
Ultrasound image velocimetry (UIV) allows for the non-intrusive measurement of a wide range of flows without the need for optical transparency. In this study, we used UIV to measure the local velocity field of a model drilling fluid that exhibits yield stress flow behavior. The radial velocity profile was used to determine the yield stress and the Herschel–Bulkley model flow index n and the consistency index k . Reference data were obtained using the conventional offline Couette rheometry. A comparison showed reasonable agreement between the two methods. The discrepancy in model parameters could be attributed to inherent differences between the methods, which cannot be captured by the three-parameter model used. Overall, with a whole flow field measurement technique such as UIV, we were able to quantify the complex rheology of a model drilling fluid. These preliminary results show that UIV can be used as a non-intrusive diagnostic for in situ , real-time measurement of complex opaque flow rheology.
- 1 January 2016
- Published by Society of Rheology in Journal of Rheology
- Vol. 60 (1) , 97-110
Planar contraction flow of a nematic PPTA solution
Planar contraction flow of a nematic solution of poly-paraphenylene terephthalamide (PPTA) in sulphuric acid (H2SO4) was studied experimentally and compared with the flow of an isotropic model fluid, a poly-ethyleneglycol–poly-ethyleneoxide (PEG-PEO) Boger fluid, in the same geometry. The dimensions and deformation rates in our experiments are relevant for industrial polymer extrusion processes, such as fiber spinning. Under these conditions, viscoelastic lip vortices arise at the re-entrant corners in the nematic flow. The experimental results show that the vortex growth behavior in the nematic PPTA solution closely resembles that in isotropic viscoelastic fluids, such as the PEG-PEO Boger fluid that was used as a reference. The velocity field in the nematic flow is characteristic of Hele-Shaw flow of a shear-thinning power-law fluid, although locally, the influence of the nematic defect structure was observed, especially for the first minutes after starting the flow. Furthermore, the lateral movement of the extruded jet, downstream of the contraction, was shown to be coupled with velocity fluctuations in the upstream flow. Our experiments give detailed insight in the complex flow behavior of a nematic polymer solution under flow conditions that are relevant to practical applications. The results can be applied in the optimization of nematic polymer extrusion processes.
- 1 January 2016
- Published by Society of Rheology in Journal of Rheology
- Vol. 60 (1) , 97-110
Planar contraction flow of a nematic PPTA solution
Planar contraction flow of a nematic solution of poly-paraphenylene terephthalamide (PPTA) in sulphuric acid (H2SO4) was studied experimentally and compared with the flow of an isotropic model fluid, a poly-ethyleneglycol–poly-ethyleneoxide (PEG-PEO) Boger fluid, in the same geometry. The dimensions and deformation rates in our experiments are relevant for industrial polymer extrusion processes, such as fiber spinning. Under these conditions, viscoelastic lip vortices arise at the re-entrant corners in the nematic flow. The experimental results show that the vortex growth behavior in the nematic PPTA solution closely resembles that in isotropic viscoelastic fluids, such as the PEG-PEO Boger fluid that was used as a reference. The velocity field in the nematic flow is characteristic of Hele-Shaw flow of a shear-thinning power-law fluid, although locally, the influence of the nematic defect structure was observed, especially for the first minutes after starting the flow. Furthermore, the lateral movement of the extruded jet, downstream of the contraction, was shown to be coupled with velocity fluctuations in the upstream flow. Our experiments give detailed insight in the complex flow behavior of a nematic polymer solution under flow conditions that are relevant to practical applications. The results can be applied in the optimization of nematic polymer extrusion processes.
- 27 May 2015
- Published by Springer Nature in Korea-Australia Rheology Journal
- Vol. 27 (2) , 105-111
An implicit rheological model for numerical simulation of generalized Newtonian fluids
- 27 May 2015
- Published by Springer Nature in Korea-Australia Rheology Journal
- Vol. 27 (2) , 105-111
An implicit rheological model for numerical simulation of generalized Newtonian fluids
- 1 November 2014
- Published by Elsevier in Journal of Non-Newtonian Fluid Mechanics
- Vol. 213, 31-38
Interaction effects in multi-outlet viscoelastic contraction flow
- 1 November 2014
- Published by Elsevier in Journal of Non-Newtonian Fluid Mechanics
- Vol. 213, 31-38
Interaction effects in multi-outlet viscoelastic contraction flow
- Open Access
- 1 November 2013
- Published by Society of Rheology in Journal of Rheology
- Vol. 57 (6) , 1787-1801
Hele-Shaw rheometry
In this paper, we describe a novel approach to determine the flow behavior index of a power-law fluid by means of a microfluidic device. The concept of this method is based on a mathematical analysis by Aronsson and Janfalk [Eur. J. Appl. Math. 3, 343–366 (1992)] of Hele-Shaw flow of power-law liquids. We implement this approach by driving a non-Newtonian fluid through a glass microfluidic chip with a 100:1 contraction. The flow in this chip satisfies the Hele-Shaw flow conditions in most of the device. Two conjugate p-Laplace equations describe the pressure and stream function in such flows. These equations depend on the flow behavior index, n. Therefore, by fitting the p-Laplace equation to the velocity field obtained from a micro particle image velocimetry measurement of the flow, the flow behavior index of the fluid in the chip can be determined. Because in practice, fluids rarely show perfectly inelastic power-law behavior, conditions under which the assumption of inelastic flow is valid were derived by analyzing Hele-Shaw flow of an Oldroyd-B fluid. The concept was tested using three different classes of model fluids, a Newtonian fluid, an inelastic power-law fluid, and a Boger fluid. In all three cases, satisfactory results were obtained, with values of n deviating at most 4% from values measured using conventional rheometry. The method presented here is expected to be potentially useful in online quality control in, for example, polymer or food processing
- 1 November 2013
- Published by Society of Rheology in Journal of Rheology
- Vol. 57 (6) , 1787-1801
Open AccessHele-Shaw rheometry
In this paper, we describe a novel approach to determine the flow behavior index of a power-law fluid by means of a microfluidic device. The concept of this method is based on a mathematical analysis by Aronsson and Janfalk [Eur. J. Appl. Math. 3, 343–366 (1992)] of Hele-Shaw flow of power-law liquids. We implement this approach by driving a non-Newtonian fluid through a glass microfluidic chip with a 100:1 contraction. The flow in this chip satisfies the Hele-Shaw flow conditions in most of the device. Two conjugate p-Laplace equations describe the pressure and stream function in such flows. These equations depend on the flow behavior index, n. Therefore, by fitting the p-Laplace equation to the velocity field obtained from a micro particle image velocimetry measurement of the flow, the flow behavior index of the fluid in the chip can be determined. Because in practice, fluids rarely show perfectly inelastic power-law behavior, conditions under which the assumption of inelastic flow is valid were derived by analyzing Hele-Shaw flow of an Oldroyd-B fluid. The concept was tested using three different classes of model fluids, a Newtonian fluid, an inelastic power-law fluid, and a Boger fluid. In all three cases, satisfactory results were obtained, with values of n deviating at most 4% from values measured using conventional rheometry. The method presented here is expected to be potentially useful in online quality control in, for example, polymer or food processing