Despite design improvements, wear of artificial implants remains a serious health issue particularly for Metal-on-Metal (MoM) hips where the formation of metallic wear debris has been linked to adverse tissue response. Clearly it is important to understand the fundamental lubrication mechanisms which control the wear process. It is usually assumed that MoM hips operate in the ElastoHydrodynamic Lubrication (EHL) regime where film formation is governed by the bulk fluid viscosity; however there is little experimental evidence of this. The current paper critically examines synovial fluid lubrication mechanisms and the effect of synovial fluid chemistry. Two composition parameters were chosen; protein content and pH, both of which are known to change in diseased or post-operative synovial fluid. Film thickness and wear tests were carried out for a series of model synovial fluid solutions. Two distinct film formation mechanisms were identified; an adsorbed surface film and a high-viscosity gel. The entrainment of this gel controls film formation particularly at low speeds. However wear of the femoral head still occurs and this is thought to be due primarily to a tribo-corrosion mechanisms. The implications of this new lubrication mechanism and the effect of different synovial fluid chemistries are examined. One important conclusion is that patient synovial fluid chemistry plays an important role in determining implant wear and the likelihood of failure.Keywords
This publication has 23 references indexed in Scilit:
- Lubricating film thickness measurements with bovine serumTribology International, 2011
- Characterization of protein degradation in serum‐based lubricants during simulation wear testing of metal‐on‐metal hip prosthesesJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2010
- The adsorption and lubrication behavior of synovial fluid proteins and glycoproteins on the bearing-surface materials of hip replacementsBiomaterials, 2009
- A study of the effect of model geometry and lubricant rheology upon the elastohydrodynamic lubrication performance of metal-on-metal hip jointsProceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology, 2008
- Biotribocorrosion of CoCrMo orthopaedic implant materials—Assessing the formation and effect of the biofilmTribology International, 2007
- Rheopexy of synovial fluid and protein aggregationJournal of The Royal Society Interface, 2005
- Effect of synovial fluid, phosphate‐buffered saline solution, and water on the dissolution and corrosion properties of CoCrMo alloys as used in orthopedic implantsJournal of Biomedical Materials Research Part A, 2005
- The effects of lubricant composition on in vitro wear testing of polymeric acetabular componentsJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2003
- Adsorption of Bovine Serum Albumin on Chromium and Molybdenum Surfaces Investigated by Fourier-Transform Infrared Reflection−Absorption Spectroscopy (FT-IRRAS) and X-ray Photoelectron SpectroscopyThe Journal of Physical Chemistry B, 2003
- The Development of a Spacer Layer Imaging Method (SLIM) for Mapping Elastohydrodynamic ContactsTribology Transactions, 1996