Philippa M. Cann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Philippa M. Cann has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Hugh A. Spikes
Tribology Group, Department of Mechanical Engineering, Imperial College London, London, UK
4 shared publications H.A. Spikes
Imperial College
3 shared publications- Marc A. Masen
Tribology Group, Department of Mechanical Engineering, Imperial College London, London, United Kingdom
3 shared publications M. Masen
Imperial College
2 shared publications- Ben Hanson
International Dysphagia Diet Standardisation Initiative Vancouver Canada
1 shared publication - Catherine Tuleu
UCL School of Pharmacy, University College London
1 shared publication
Latest Publications
- Open Access
- 6 October 2025
- Published by American Chemical Society (ACS) in ChemRxiv
A Coarse-Grained MARTINI Model for Mucins
Highly glycosylated proteins known as mucins are the principal components of mucus, the gel-like secretion that protects and lubricates many tissues in the human body. Molecular dynamics (MD) simulations are a useful tool to investigate the nanoscale structure and function of proteins; however, the high molecular weight of mucins makes them a challenging target for atomistic MD simulations. To enable long-time MD simulations of large mucins, we develop and validate new coarse-grained force field parameters within the MARTINI 3 framework for the glycosylated domains of salivary mucin, MUC5B. We use atomistic MD simulations of segments of the protein backbone connected to O-glycans with the CHARMM36m force field to parameterize the bonded parameters. The structural properties of MUC5B from the MD simulations with MARTINI 3, including the radius of gyration, end-to-end distance, and solvent accessible surface area, agree well with the atomistic simulations. Our MARTINI 3 parameters reproduce the bottlebrush structure of MUC5B observed in atomistic MD simulations and previous experiments. The power-law scaling of the radius of gyration with molecular weight is within the range observed in previous experiments of mucins. Accordingly, the MARTINI 3 parameters developed and validated in this study will facilitate accurate and efficient MD simulations of mucins and other glycoproteins for a variety of application areas including food science, drug delivery, and biomaterials.
- 6 October 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessA Coarse-Grained MARTINI Model for Mucins
Highly glycosylated proteins known as mucins are the principal components of mucus, the gel-like secretion that protects and lubricates many tissues in the human body. Molecular dynamics (MD) simulations are a useful tool to investigate the nanoscale structure and function of proteins; however, the high molecular weight of mucins makes them a challenging target for atomistic MD simulations. To enable long-time MD simulations of large mucins, we develop and validate new coarse-grained force field parameters within the MARTINI 3 framework for the glycosylated domains of salivary mucin, MUC5B. We use atomistic MD simulations of segments of the protein backbone connected to O-glycans with the CHARMM36m force field to parameterize the bonded parameters. The structural properties of MUC5B from the MD simulations with MARTINI 3, including the radius of gyration, end-to-end distance, and solvent accessible surface area, agree well with the atomistic simulations. Our MARTINI 3 parameters reproduce the bottlebrush structure of MUC5B observed in atomistic MD simulations and previous experiments. The power-law scaling of the radius of gyration with molecular weight is within the range observed in previous experiments of mucins. Accordingly, the MARTINI 3 parameters developed and validated in this study will facilitate accurate and efficient MD simulations of mucins and other glycoproteins for a variety of application areas including food science, drug delivery, and biomaterials.
- Open Access
- 18 October 2024
- Published by Elsevier in Engineering Failure Analysis
- Vol. 167
Effect of radiation on lubrication performance and the consequences for mechanical equipment at CERN
- 18 October 2024
- Published by Elsevier in Engineering Failure Analysis
- Vol. 167
Open AccessEffect of radiation on lubrication performance and the consequences for mechanical equipment at CERN
- Open Access
- 29 March 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (4) , 732
Modernising Orodispersible Film Characterisation to Improve Palatability and Acceptability Using a Toolbox of Techniques
Orodispersible films (ODFs) have been widely used in paediatric, geriatric and dysphagic patients due to ease of administration and precise and flexible dose adjustments. ODF fabrication has seen significant advancements with the move towards more technologically advanced production methods. The acceptability of ODFs is dependent upon film composition and process of formation, which affects disintegration, taste, texture and mouthfeel. There is currently a lack of testing to accurately assess ODFs for these important acceptability sensory perceptions. This study produced four ODFs formed of polyvinyl alcohol and sodium carboxymethylcellulose using 3D printing. These were assessed using three in vitro methods: Petri dish and oral cavity model (OCM) methods for disintegration and bio-tribology for disintegration and oral perception. Increasing polymer molecular weight (MW) exponentially increased disintegration time in the Petri dish and OCM methods. Higher MW films adhered to the OCM upper palate. Bio-tribology analysis showed that films of higher MW disintegrated quickest and had lower coefficient of friction, perhaps demonstrating good oral perception but also stickiness, with higher viscosity. These techniques, part of a toolbox, may enable formulators to design, test and reformulate ODFs that both disintegrate rapidly and may be better perceived when consumed, improving overall treatment acceptability.
- 29 March 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (4) , 732
Open AccessModernising Orodispersible Film Characterisation to Improve Palatability and Acceptability Using a Toolbox of Techniques
Orodispersible films (ODFs) have been widely used in paediatric, geriatric and dysphagic patients due to ease of administration and precise and flexible dose adjustments. ODF fabrication has seen significant advancements with the move towards more technologically advanced production methods. The acceptability of ODFs is dependent upon film composition and process of formation, which affects disintegration, taste, texture and mouthfeel. There is currently a lack of testing to accurately assess ODFs for these important acceptability sensory perceptions. This study produced four ODFs formed of polyvinyl alcohol and sodium carboxymethylcellulose using 3D printing. These were assessed using three in vitro methods: Petri dish and oral cavity model (OCM) methods for disintegration and bio-tribology for disintegration and oral perception. Increasing polymer molecular weight (MW) exponentially increased disintegration time in the Petri dish and OCM methods. Higher MW films adhered to the OCM upper palate. Bio-tribology analysis showed that films of higher MW disintegrated quickest and had lower coefficient of friction, perhaps demonstrating good oral perception but also stickiness, with higher viscosity. These techniques, part of a toolbox, may enable formulators to design, test and reformulate ODFs that both disintegrate rapidly and may be better perceived when consumed, improving overall treatment acceptability.
- Open Access
- 1 November 2020
- Published by Elsevier in Current Research in Food Science
- Vol. 3, 304-313
Measurement of molten chocolate friction under simulated tongue-palate kinematics: Effect of cocoa solids content and aeration
- 1 November 2020
- Published by Elsevier in Current Research in Food Science
- Vol. 3, 304-313
Open AccessMeasurement of molten chocolate friction under simulated tongue-palate kinematics: Effect of cocoa solids content and aeration
- Open Access
- 10 February 2018
- Published by Springer Nature in Tribology Letters
- Vol. 66 (1) , 46
Correction to: Friction Measurements with Molten Chocolate
- 10 February 2018
- Published by Springer Nature in Tribology Letters
- Vol. 66 (1) , 46
Open AccessCorrection to: Friction Measurements with Molten Chocolate
- Open Access
- 26 December 2017
- Published by Springer Nature in Tribology Letters
- Vol. 66 (1) , 24
Friction Measurements with Molten Chocolate
- 26 December 2017
- Published by Springer Nature in Tribology Letters
- Vol. 66 (1) , 24
Open AccessFriction Measurements with Molten Chocolate
- Open Access
- 1 July 2017
- Published by Elsevier in Journal of Biomechanics
- Vol. 60, 261-265
Real-time observation of fluid flows in tissue during stress relaxation using Raman spectroscopy
- 1 July 2017
- Published by Elsevier in Journal of Biomechanics
- Vol. 60, 261-265
Open AccessReal-time observation of fluid flows in tissue during stress relaxation using Raman spectroscopy
- 1 January 2013
- Published by Springer Nature
- p. 259-262
Boundary Lubrication Mechanisms in Artificial Joints
- 1 January 2013
- Published by Springer Nature
- p. 259-262
Boundary Lubrication Mechanisms in Artificial Joints
- 6 February 2012
- Published by Royal Society of Chemistry (RSC) in Faraday Discussions
- Vol. 156, 69-85
Synovial fluid lubrication of artificial joints: protein film formation and composition
Despite design improvements, wear of artificial implants remains a serious health issue particularly for Metal-on-Metal (MoM) hips where the formation of metallic wear debris has been linked to adverse tissue response. Clearly it is important to understand the fundamental lubrication mechanisms which control the wear process. It is usually assumed that MoM hips operate in the ElastoHydrodynamic Lubrication (EHL) regime where film formation is governed by the bulk fluid viscosity; however there is little experimental evidence of this. The current paper critically examines synovial fluid lubrication mechanisms and the effect of synovial fluid chemistry. Two composition parameters were chosen; protein content and pH, both of which are known to change in diseased or post-operative synovial fluid. Film thickness and wear tests were carried out for a series of model synovial fluid solutions. Two distinct film formation mechanisms were identified; an adsorbed surface film and a high-viscosity gel. The entrainment of this gel controls film formation particularly at low speeds. However wear of the femoral head still occurs and this is thought to be due primarily to a tribo-corrosion mechanisms. The implications of this new lubrication mechanism and the effect of different synovial fluid chemistries are examined. One important conclusion is that patient synovial fluid chemistry plays an important role in determining implant wear and the likelihood of failure.
- 6 February 2012
- Published by Royal Society of Chemistry (RSC) in Faraday Discussions
- Vol. 156, 69-85
Synovial fluid lubrication of artificial joints: protein film formation and composition
Despite design improvements, wear of artificial implants remains a serious health issue particularly for Metal-on-Metal (MoM) hips where the formation of metallic wear debris has been linked to adverse tissue response. Clearly it is important to understand the fundamental lubrication mechanisms which control the wear process. It is usually assumed that MoM hips operate in the ElastoHydrodynamic Lubrication (EHL) regime where film formation is governed by the bulk fluid viscosity; however there is little experimental evidence of this. The current paper critically examines synovial fluid lubrication mechanisms and the effect of synovial fluid chemistry. Two composition parameters were chosen; protein content and pH, both of which are known to change in diseased or post-operative synovial fluid. Film thickness and wear tests were carried out for a series of model synovial fluid solutions. Two distinct film formation mechanisms were identified; an adsorbed surface film and a high-viscosity gel. The entrainment of this gel controls film formation particularly at low speeds. However wear of the femoral head still occurs and this is thought to be due primarily to a tribo-corrosion mechanisms. The implications of this new lubrication mechanism and the effect of different synovial fluid chemistries are examined. One important conclusion is that patient synovial fluid chemistry plays an important role in determining implant wear and the likelihood of failure.
- 2 March 2007
- Published by Wiley in Lubrication Science
- Vol. 19 (3) , 183-196
Grease lubrication of rolling element bearings — role of the grease thickener
The contribution of grease thickener to lubricant film formation was examined in this paper. Lubricant film thickness and friction were measured for different grease thickener types in a bearing simulation device. The results showed that the greases formed thick (20–80nm), low friction surface layers at low speeds, which were much greater than the corresponding base oil film. These films appeared to be formed by the physical deposition of thickener in the track during overrolling of the grease. This was confirmed by infrared reflection analysis, which showed the deposited films to have increased thickener content. The ability of grease to form renewable physically deposited solid films has significant implications for optimising lubricant formulation for certain applications, e.g. bearings operating at high temperatures and low speeds where a conventional elastohydrodynamic lubricating film would be inadequate. Copyright © 2007 John Wiley & Sons, Ltd.
- 2 March 2007
- Published by Wiley in Lubrication Science
- Vol. 19 (3) , 183-196
Grease lubrication of rolling element bearings — role of the grease thickener
The contribution of grease thickener to lubricant film formation was examined in this paper. Lubricant film thickness and friction were measured for different grease thickener types in a bearing simulation device. The results showed that the greases formed thick (20–80nm), low friction surface layers at low speeds, which were much greater than the corresponding base oil film. These films appeared to be formed by the physical deposition of thickener in the track during overrolling of the grease. This was confirmed by infrared reflection analysis, which showed the deposited films to have increased thickener content. The ability of grease to form renewable physically deposited solid films has significant implications for optimising lubricant formulation for certain applications, e.g. bearings operating at high temperatures and low speeds where a conventional elastohydrodynamic lubricating film would be inadequate. Copyright © 2007 John Wiley & Sons, Ltd.